948 research outputs found
Multiproduct Uniform Polar Quantizer
The aim of this paper is to reduce the complexity of the unrestricted uniform polar quantizer (UUPQ), keeping its high performances. To achieve this, in this paper we propose the multiproduct uniform polar quantizer (MUPQ), where several consecutive magnitude levels are joined in segments and within each segment the uniform product quantization is performed (i.e. all levels within one segments have the same number of phase levels). MUPQ is much simpler for realization than UUPQ, but it achieves similar performances as UUPQ. Since MUPQ has low complexity and achieves much better performances than the scalar uniform quantizer, it can be widely used instead of scalar uniform quantizers to improve performances, for any signal with the Gaussian distribution
Log-Polar Quantizer with the Embedded G.711 Codec
In this paper a new two-dimensional vector quantizer for memoryless Gaussian source, realized in polar coordinates, is proposed. The G.711 codec is embedded in our vector quantizer, and therefore our vector quantizer is compatible with the G.711 codec. It is simple for realization and it has much better performances, compared to the G.711 codec, such as much higher SQNR (signal-to-quantization noise ratio) for the same bit-rate, or bit-rate decrease for the same SQNR. The G.711 codec is widely used in many systems, especially in PSTN (public switched telephone network). Due to compatibility with the G.711 standard, our vector quantizer can be realized with simple software modification of the existing the G.711 codec, and therefore it can be very easily implemented in PSTN and other systems. So, small investments are needed for wide implementation of our model, but significant improvement of performances can be obtained
Design and standalone characterisation of a capacitively coupled HV-CMOS sensor chip for the CLIC vertex detector
The concept of capacitive coupling between sensors and readout chips is under
study for the vertex detector at the proposed high-energy CLIC electron
positron collider. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is an
active High-Voltage CMOS sensor, designed to be capacitively coupled to the
CLICpix2 readout chip. The chip is implemented in a commercial nm HV-CMOS
process and contains a matrix of square pixels with m
pitch. First prototypes have been produced with a standard resistivity of
cm for the substrate and tested in standalone mode. The
results show a rise time of ns, charge gain of mV/ke and
e RMS noise for a power consumption of W/pixel. The
main design aspects, as well as standalone measurement results, are presented.Comment: 13 pages, 13 figures, 2 tables. Work carried out in the framework of
the CLICdp collaboratio
Ganglión migratorio tibio-peroneo proximal como causa de parálisis del ciático poplíteo externo
Se present a el caso de un ganglion de la articulación tibio-peronea proximal
que se extendió a la musculatura peronea, el nervio peroneo profundo, ligamento lateral
externo y menisco externo y ocasionó paresia del ciático poplíteo externo. Tuvo evolución
recidivante por lo cual fue intervenido en 4 oportunidades; en la última se realizó una
transposición tendinos a por parálisis del nervio peroneo profundo. El paciente evolucionó satisfactoriamente con recuperación de la función y desaparición del dolor. El caso presenta
interés ya que ofrece una problemática en cuanto a su origen, presentación clínica, evolución
con compromiso neurológico y dificultad en el tratamiento quirúrgico resolutivo.A synovia l cyst attache d t o th e proxima l tibiofibula r join t is described
. Th e cyst spreade d int o th e peronea l muscl e group , th e dee p peronea l nerve , th e
fibula r collatera l ligamen t an d latera l meniscu s producin g a peronea l nerv e paresis.
T h e cyst recurre d an d th e patien t underwen t surger y i n 4 times; i n th e last on e a
tendinou s transpositio n wa s performe d t o resolv e a dee p peronea l nerv e paralysis.
T h e patien t ha d a goo d evolutio n eit h functio n recover y an d absces e o f pain . Th e cas e
illustrate s th e origin , clinica l aspects, evolutio n wit h neuropath y an d difficult sur -
gica l resectio n o f this entity
Novel Silicon n-in-p Pixel Sensors for the future ATLAS Upgrades
In view of the LHC upgrade phases towards HL-LHC the ATLAS experiment plans
to upgrade the Inner Detector with an all silicon system. The n-in-p silicon
technology is a promising candidate for the pixel upgrade thanks to its
radiation hardness and cost effectiveness, that allow for enlarging the area
instrumented with pixel detectors. We present the characterization and
performance of novel n-in-p planar pixel sensors produced by CiS (Germany)
connected by bump bonding to the ATLAS readout chip FE-I3. These results are
obtained before and after irradiation up to a fluence of 10^16 1-MeV n_eq/cm^2,
and prove the operability of this kind of sensors in the harsh radiation
environment foreseen for the pixel system at HL-LHC. We also present an
overview of the new pixel production, which is on-going at CiS for sensors
compatible with the new ATLAS readout chip FE-I4.Comment: Preprint submitted to NIM-A Proceedings (Elba 2012
Union after multiple anterior cervical fusion 21 cases followed for 1-6 years
With a mean follow-up of 3 (1-6) years, we report on 21 patients who underwent
multiple level cervical fusion, using autologous iliac crest grafts. Dissectomies
were performed in 14 patients and corpectomies in another 7. Instrumentation was
used in all patients with corpectomies and in 2 patients who underwent 2-level
and 3-level dissectomies. Non-union occurred in 1 patient at 1 level. Graft
displacement requiring reoperation was observed in 2 patients with massive
corpectomies, in 1 of them as a consequence of trauma. In both patients complete
bony fusion was obtained after reoperation and no other complications were
observed. We conclude that the success rate with multiple-level fusion is
comparable to that of single-level fusion when adequate fixation is achieve
Angioleiomioma de nervio periférico
Se realiza una revisión bibliográfica y se presenta un caso de angioleiomioma
localizado en borde cubital de muñeca izquierda, en el ramo dorsal sensitivo del
nervio cubital. Este tumor debe ser considerado en el diagnóstico diferencial de los nodulos
subcutáneos dolorosos localizados en extremidades. No hemos encontrado descrito
este tipo de tumor en un nervio periférico.A cas e of angioleiomyoma on the medial aspec t of the left wrist in the
dorsal sensitive branch of the ulnar nerve, and a review of the literatur e are presented.
This tumor should be considered in the differential diagnosis of patients who have
a painful subcutaneous nodul e at the extremities. Ther e is no report in the literatur e
on this type of tumor affecting a peripheral nerve
Prototyping of an HV-CMOS demonstrator for the High Luminosity-LHC upgrade
HV-CMOS sensors can offer important advantages in terms of material budget, granularity and cost for large area tracking systems in high energy physics experiments. This article presents the design and simulated results of an HV-CMOS pixel demonstrator for the High Luminosity-LHC. The pixel demonstrator has been designed in the 0.35 μm HV-CMOS process from ams AG and submitted for fabrication through an engineering run. To improve the response of the sensor, different wafers with moderate to high substrate resistivities are used to fabricate the design. The prototype consists of four large analog and standalone matrices with several pixel flavours, which are all compatible for readout with the FE-I4 ASIC. Details about the matrices and the pixel flavours are provided in this article
Status of a DEPFET pixel system for the ILC vertex detector
We have developed a prototype system for the ILC vertex detector based on
DEPFET pixels. The system operates a 128x64 matrix (with ~35x25 square micron
large pixels) and uses two dedicated microchips, the SWITCHER II chip for
matrix steering and the CURO II chip for readout. The system development has
been driven by the final ILC requirements which above all demand a detector
thinned to 50 micron and a row wise read out with line rates of 20MHz and more.
The targeted noise performance for the DEPFET technology is in the range of
ENC=100 e-. The functionality of the system has been demonstrated using
different radioactive sources in an energy range from 6 to 40keV. In recent
test beam experiments using 6GeV electrons, a signal-to-noise ratio of S/N~120
has been achieved with present sensors being 450 micron thick. For improved
DEPFET systems using 50 micron thin sensors in future, a signal-to-noise of 40
is expected.Comment: Invited poster at the International Symposium on the Development of
Detectors for Particle, AstroParticle and Synchrotron Radiation Experiments,
Stanford CA (SNIC06) 6 pages, 12 eps figure
- …