1,111 research outputs found
Recommended from our members
Results for Channel Error Profiles for DECT
This letter presents the main statistical characterization
of the underlying error process obtained in the case of
the Digital European Cordless Telecommunications (DECT) radio
system. By simulation of the transmission link, error sequences
are generated for different channel parameters. Relevant statistics
are then computed for the purpose of efficient channel coding
design and evaluation
Scalable multicomponent spectral analysis for high-throughput data annotation
Orchestrating parametric fitting of multicomponent spectra at scale is an essential yet underappreciated task in high-throughput quantification of materials and chemical composition. We present a systematic approach compatible with high-performance computing infrastructures using the MapReduce model and task-based parallelization. Our approach is realized in a software, pesfit, to enable efficient generation of high-quality data annotation and online spectral analysis as demonstrated using experimental materials characterization datasets
Global rank-invariant set normalization (GRSN) to reduce systematic distortions in microarray data
<p>Abstract</p> <p>Background</p> <p>Microarray technology has become very popular for globally evaluating gene expression in biological samples. However, non-linear variation associated with the technology can make data interpretation unreliable. Therefore, methods to correct this kind of technical variation are critical. Here we consider a method to reduce this type of variation applied after three common procedures for processing microarray data: MAS 5.0, RMA, and dChip<sup>®</sup>.</p> <p>Results</p> <p>We commonly observe intensity-dependent technical variation between samples in a single microarray experiment. This is most common when MAS 5.0 is used to process probe level data, but we also see this type of technical variation with RMA and dChip<sup>® </sup>processed data. Datasets with unbalanced numbers of up and down regulated genes seem to be particularly susceptible to this type of intensity-dependent technical variation. Unbalanced gene regulation is common when studying cancer samples or genetically manipulated animal models and preservation of this biologically relevant information, while removing technical variation has not been well addressed in the literature. We propose a method based on using rank-invariant, endogenous transcripts as reference points for normalization (GRSN). While the use of rank-invariant transcripts has been described previously, we have added to this concept by the creation of a global rank-invariant set of transcripts used to generate a robust average reference that is used to normalize all samples within a dataset. The global rank-invariant set is selected in an iterative manner so as to preserve unbalanced gene expression. Moreover, our method works well as an overlay that can be applied to data already processed with other probe set summary methods. We demonstrate that this additional normalization step at the "probe set level" effectively corrects a specific type of technical variation that often distorts samples in datasets.</p> <p>Conclusion</p> <p>We have developed a simple post-processing tool to help detect and correct non-linear technical variation in microarray data and demonstrate how it can reduce technical variation and improve the results of downstream statistical gene selection and pathway identification methods.</p
Auto- and cross-power spectral analysis of dual trap optical tweezer experiments using Bayesian inference
The thermal fluctuations of micron-sized beads in dual trap optical tweezer experiments contain complete dynamic information about the viscoelastic properties of the embedding medium and—if present—macromolecular constructs connecting the two beads. To quantitatively interpret the spectral properties of the measured signals, a detailed understanding of the instrumental characteristics is required. To this end, we present a theoretical description of the signal processing in a typical dual trap optical tweezer experiment accounting for polarization crosstalk and instrumental noise and discuss the effect of finite statistics. To infer the unknown parameters from experimental data, a maximum likelihood method based on the statistical properties of the stochastic signals is derived. In a first step, the method can be used for calibration purposes: We propose a scheme involving three consecutive measurements (both traps empty, first one occupied and second empty, and vice versa), by which all instrumental and physical parameters of the setup are determined. We test our approach for a simple model system, namely a pair of unconnected, but hydrodynamically interacting spheres. The comparison to theoretical predictions based on instantaneous as well as retarded hydrodynamics emphasizes the importance of hydrodynamic retardation effects due to vorticity diffusion in the fluid. For more complex experimental scenarios, where macromolecular constructs are tethered between the two beads, the same maximum likelihood method in conjunction with dynamic deconvolution theory will in a second step allow one to determine the viscoelastic properties of the tethered element connecting the two beads
Distribution and frequency of VKORC1 sequence variants conferring resistance to anticoagulants in Mus musculus
Pelz, H.-J., Rost, S., Müller, E., Esther, A., Ulrich, R.G., Müller, C.R
The analytic structure of 2D Euler flow at short times
Using a very high precision spectral calculation applied to the
incompressible and inviscid flow with initial condition , we find that the width of its analyticity
strip follows a law at short times over eight decades. The
asymptotic equation governing the structure of spatial complex-space
singularities at short times (Frisch, Matsumoto and Bec 2003, J.Stat.Phys. 113,
761--781) is solved by a high-precision expansion method. Strong numerical
evidence is obtained that singularities have infinite vorticity and lie on a
complex manifold which is constructed explicitly as an envelope of analyticity
disks.Comment: 19 pages, 14 figures, published versio
Detection of interstellar hydrogen peroxide
The molecular species hydrogen peroxide, HOOH, is likely to be a key
ingredient in the oxygen and water chemistry in the interstellar medium. Our
aim with this investigation is to determine how abundant HOOH is in the cloud
core {\rho} Oph A. By observing several transitions of HOOH in the
(sub)millimeter regime we seek to identify the molecule and also to determine
the excitation conditions through a multilevel excitation analysis. We have
detected three spectral lines toward the SM1 position of {\rho} Oph A at
velocity-corrected frequencies that coincide very closely with those measured
from laboratory spectroscopy of HOOH. A fourth line was detected at the
4{\sigma} level. We also found through mapping observations that the HOOH
emission extends (about 0.05 pc) over the densest part of the {\rho} Oph A
cloud core. We derive an abundance of HOOH relative to that of H_2 in the SM1
core of about 1\times10^(-10). To our knowledge, this is the first reported
detection of HOOH in the interstellar medium.Comment: 5 pages, 4 figures, accepted for publication in Astronomy &
Astrophysics, new version corrects a typo in Table 1 (and consequently in Fig
4
Seeing the body distorts tactile size perception
Vision of the body modulates somatosensation, even when entirely non-informative about stimulation. For example, seeing the body increases tactile spatial acuity, but reduces acute pain. While previous results demonstrate that vision of the body modulates somatosensory sensitivity, it is unknown whether vision also affects metric properties of touch, and if so how. This study investigated how non-informative vision of the body modulates tactile size perception. We used the mirror box illusion to induce the illusion that participants were directly seeing their stimulated left hand, though they actually saw their reflected right hand. We manipulated whether participants: (a) had the illusion of directly seeing their stimulated left hand, (b) had the illusion of seeing a non-body object at the same location, or (c) looked directly at their non-stimulated right-hand. Participants made verbal estimates of the perceived distance between two tactile stimuli presented simultaneously to the dorsum of the left hand, either 20, 30, or 40 mm apart. Vision of the body significantly reduced the perceived size of touch, compared to vision of the object or of the contralateral hand. In contrast, no apparent changes of perceived hand size were found. These results show that seeing the body distorts tactile size perception
Intra-arterial thrombolysis of occluded middle cerebral artery by use of collateral pathways in patients with tandem cervical carotid artery/middle cerebral artery occlusion
BACKGROUND AND PURPOSE: Cervical internal carotid artery (ICA) occlusion with middle cerebral artery (MCA) embolic occlusion is associated with a low rate of recanalization and poor outcome after intravenous thrombolysis. Prompt revascularization is required to prevent disabling stroke. We report our experience on acute ischemic stroke patients with tandem ICA or MCA occlusions treated with microcathether navigation and intra-arterial thrombolysis by use of collateral pathways including the posterior or anterior communicating arteries, or both pathways. MATERIALS AND METHODS: We retrospectively identified 8 patients with proximal ICA occlusion associated with MCA embolic occlusions treated with intra-arterial thrombolysis (IA rtPA). Access to the occluded MCA was obtained via catheter navigation through intact collateral pathways, including posterior communicating (PcomA) or anterior communicating (AcomA) arteries, without passing a microcathether through the acutely occluded ICA. We assessed clinical outcomes using modified Rankin scale (mRS) and National Institutes of Health Stroke Scale (NIHSS). RESULTS: Eight patients with a mean age of 57 ± 4 years and median NIHSS of 14 were identified. Mean time from stroke onset to intra-arterial thrombolysis was 292 ± 44 minutes. The MCA was revascularized completely in 5 of the 8 patients via collateral intra-arterial rtPA administration. All of the patients had a favorable outcome defined as a mRS of ≤2 or more at 1 and 3 months\u27 follow-up after thrombolytic therapy. One patient had an asymptomatic petechial hemorrhage. CONCLUSION: In this small number of patients with tandem occlusions of the ICA and MCA, intraarterial thrombolysis and recanalization of the MCA by use of collateral pathways to bypass the occluded ICA is a safe and efficacious therapeutic option
- …