104 research outputs found
Measurement of and charged current inclusive cross sections and their ratio with the T2K off-axis near detector
We report a measurement of cross section and the first measurements of the cross section
and their ratio
at (anti-)neutrino energies below 1.5
GeV. We determine the single momentum bin cross section measurements, averaged
over the T2K -flux, for the detector target material (mainly
Carbon, Oxygen, Hydrogen and Copper) with phase space restricted laboratory
frame kinematics of 500 MeV/c. The
results are and $\sigma(\nu)=\left( 2.41\
\pm0.022{\rm{(stat.)}}\pm0.231{\rm (syst.)}\ \right)\times10^{-39}^{2}R\left(\frac{\sigma(\bar{\nu})}{\sigma(\nu)}\right)=
0.373\pm0.012{\rm (stat.)}\pm0.015{\rm (syst.)}$.Comment: 18 pages, 8 figure
International prescribing patterns and polypharmacy in older people with advanced chronic kidney disease: results from the European Quality study
Background. People with chronic kidney disease (CKD) are at high risk of polypharmacy. However, no previous study has investigated international prescribing patterns in this group. This article aims to examine prescribing and polypharmacy patterns among older people with advanced CKD across the countries involved in the European Quality (EQUAL) study.Methods. The EQUAL study is an international prospective cohort study of patients >= 65 years of age with advanced CKD. Baseline demographic, clinical and medication data were analysed and reported descriptively. Polypharmacy was defined as >= 5 medications and hyperpolypharmacy as >= 10. Univariable and multivariable linear regressions were used to determine associations between country and the number of prescribed medications. Univariable and multivariable logistic regression were used to determine associations between country and hyperpolypharmacy.Results. Of the 1317 participants from five European countries, 91% were experiencing polypharmacy and 43% were experiencing hyperpolypharmacy. Cardiovascular medications were the most prescribed medications (mean 3.5 per person). There were international differences in prescribing, with significantly greater hyperpolypharmacy in Germany {odds ratio (OR) 2.75 [95% confidence interval (CI) 1.73-4.37]; P < 0.001, reference group UK}, the Netherlands [OR 1.91 (95% CI 1.32-2.76); P = 0.001] and Italy [OR 1.57 (95% CI 1.15-2.15); P = 0.004]. People in Poland experienced the least hyperpolypharmacy [OR 0.39 (95% CI 0.17-0.87); P = 0.021].Conclusions. Hyperpolypharmacy is common among older people with advanced CKD, with significant international differences in the number of medications prescribed. Practice variation may represent a lack of consensus regarding appropriate prescribing for this high-risk group for whom pharmacological treatment has great potential for harm as well as benefit.Clinical epidemiolog
Efeitos de planos nutricionais e de fontes de metionina sobre o desempenho, rendimento e composição de carcaças de frangos de corte
Search for Lorentz and CPT violation using sidereal time dependence of neutrino flavor transitions over a short baseline
A class of extensions of the Standard Model allows Lorentz and CPT violations, which can be identified
by the observation of sidereal modulations in the neutrino interaction rate. A search for such modulations
was performed using the T2K on-axis near detector. Two complementary methods were used in this study,
both of which resulted in no evidence of a signal. Limits on associated Lorentz and CPT-violating terms
from the Standard Model extension have been derived by taking into account their correlations in this
model for the first time. These results imply such symmetry violations are suppressed by a factor of more
than 10 20 at the GeV scale
Recommended from our members
Gaia Early Data Release 3: The celestial reference frame (Gaia-CRF3)
Context. Gaia-CRF3 is the celestial reference frame for positions and proper motions in the third release of data from the Gaia mission, Gaia DR3 (and for the early third release, Gaia EDR3, which contains identical astrometric results). The reference frame is defined by the positions and proper motions at epoch 2016.0 for a specific set of extragalactic sources in the (E)DR3 catalogue. Aims. We describe the construction of Gaia-CRF3 and its properties in terms of the distributions in magnitude, colour, and astrometric quality. Methods. Compact extragalactic sources in Gaia DR3 were identified by positional cross-matching with 17 external catalogues of quasi-stellar objects (QSO) and active galactic nuclei (AGN), followed by astrometric filtering designed to remove stellar contaminants. Selecting a clean sample was favoured over including a higher number of extragalactic sources. For the final sample, the random and systematic errors in the proper motions are analysed, as well as the radio-optical offsets in position for sources in the third realisation of the International Celestial Reference Frame (ICRF3). Results. Gaia-CRF3 comprises about 1.6 million QSO-like sources, of which 1.2 million have five-parameter astrometric solutions in Gaia DR3 and 0.4 million have six-parameter solutions. The sources span the magnitude range G = 13-21 with a peak density at 20.6 mag, at which the typical positional uncertainty is about 1 mas. The proper motions show systematic errors on the level of 12 μas yr-1 on angular scales greater than 15 deg. For the 3142 optical counterparts of ICRF3 sources in the S/X frequency bands, the median offset from the radio positions is about 0.5 mas, but it exceeds 4 mas in either coordinate for 127 sources. We outline the future of Gaia-CRF in the next Gaia data releases. Appendices give further details on the external catalogues used, how to extract information about the Gaia-CRF3 sources, potential (Galactic) confusion sources, and the estimation of the spin and orientation of an astrometric solution
Farelo integral de arroz parboilizado submetido a armazenamento prolongado para alimentação de codornas de corte
Recent advances in the chemistry of gold(I) complexes with C-, N- and S-donor ligands part I: alkynyl, amino, imino and nitrido derivatives
Measurement of coherent production in low energy neutrino-Carbon scattering
We report the first measurement of the flux-averaged cross section for charged current coherent production on carbon for neutrino energies less than 1.5 GeV to a restricted final state phase space region in the T2K near detector, ND280. Comparisons are made with predictions from the Rein-Sehgal coherent production model and the model by Alvarez-Ruso {\it et al.}, the latter representing the first implementation of an instance of the new class of microscopic coherent models in a neutrino interaction Monte Carlo event generator. This results contradicts the null results reported by K2K and SciBooNE in a similar neutrino energy region
Scintillator ageing of the T2K near detectors from 2010 to 2021
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation
- …