317 research outputs found

    Small-scale Vacuum System for Deposition of Multilayer Metallic Films “MVU TM – Magna 3M”

    Get PDF
    A new small-scale vacuum system “MVU TM-Magna 3M” developed at JSC “Research Institute of Pre-cision Machine Manufacturing” is described. Its assembly and working conditions are considered. This sys-tem was used for magnetron sputtering multilayer metallic films. When you are citing the document, use the following link http://essuir.sumdu.edu.ua/handle/123456789/3612

    ESTIMATION OF PREDICTION EFFICIENCY OF SEISMIC REGIME PROBABILISTIC MODEL PARAMETERS

    Get PDF
    On the basis of theoretical-probabilistic approach to the Kamchatka earthquakes catalog the subset of random events was specified and their probabilities were calculated. The received probabilities of random events considered as predictors of strong earthquakes with energy class KS 14. Their effectiveness V, reliability R and prediction efficiency (informative) J were calculated for periods of seismic activity and seismic calm

    Effect of Nitrogen Implantation on the Structure and Properties of Austenitic Corrosion-Resistant Steels

    Get PDF
    Work is devoted to studying the effect of implantation of nitrogen ions into the surface of austenitic stainless steels to improve their functional properties. Four grades of austenitic corrosion-resistant steels 02H16N10M2, 08H15AG10D2, 06H15AG9NM2 and 09H15AG9ND2 were taken after cold plastic deformation and annealing from 680 ∘C in water and subsequent implantation with N+ ions with different radiation dose: 0,01 и 0,1%. It was found that irradiation of austenitic stainless steels with nitrogen ions can be considered an effective way to increase the hardness and yield strength of steels in the operation in a corrosive environment.     Keywords: steel, austenite, nitrogen implantation, hardness, corrosion resistanc

    Terahertz lasers based on intracentre transitions of group V donors in uniaxially deformed silicon

    Get PDF
    This paper presents a brief overview of available experimental data on the characteristics of stimulated terahertz emission (4.9 – 6.4 THz) from optically excited neutral group V donors (phosphorus, antimony, arsenic and bismuth) in crystalline silicon subjected to uniaxial compressive strain along the [100] axis. Strain is shown to have a significant effect on the characteristics in question. Optimal strain depends on the dopant and may reduce the threshold pump intensity and improve lasing efficiency. We discuss possible mechanisms behind this effect and estimate the limiting output emission parameters

    ИНДИВИДУАЛЬНЫЕ ПРЕДИСПОЗИЦИИ К НЕОСОЗНАВАЕМОМУ ВОСПРИЯТИЮ ЛИЦЕВЫХ СТИМУЛОВ УГРОЗЫ И ПОЛОЖИТЕЛЬНОГО ПОДКРЕПЛЕНИЯ И КАРДИОВАСКУЛЯРНАЯ СТРЕСС-РЕАКТИВНОСТЬ

    Get PDF
    Aim: to investigate cardiovascular stress-reactivity in association with individual preconscious affective biases to threatening and appetitive facial stimuli. Patients and methods: preconscious affective biases were assessed in healthy individuals (n =38, mean age M =28,10 years, 1SD =8,64) using a modified (masked) version of a pictorial emotional Stroop task (backward masking of the angry, fearful and joyful faces). Results: it was revealed that individual preconscious bias to speeded up perception of angry faces correlates significantly with heightened anxiety, lowered platelet serotonin (5-HT) levels, sustained central overactivation of at rest (as indexed by lowered delta, theta, and beta-1 EEG power over frontal, central and posterior cortical areas) and exaggerated arterial blood pressure stress-reactivity during re-experiencing of personally relevant anger. Conclusions: considering uncovered associations, individuals with preconscious bias to speeded up perception of angry faces may be regarded as having enhanced risk to fall sick with essential hypertension, yet this perceptive bias could be seen as a putative neurobehavioral predictor of the risk. Л.И. Афтанас, С.В. Павлов, И.В. Брак, В.В. КоренекЦель исследования: изучить кардиоваскулярную стресс-реактивность в зависимости от индивидуальной предиспозиции к неосознаваемому восприятию мотивационно значимых стимулов угрозы и положительного подкрепления. Пациенты и методы: в модифицированном эмоциональном тесте Stroop с обратной зрительной маскировкой у здоровых индивидов (n =38, средний возраст M =28,10 года, 1SD =8,64) проведен анализ индивидуальных предиспозиций неосознаваемого восприятия эмоционально значимых лиц с выражениями гнева, страха и радости. Результаты: установлено, что индивидуальная предиспозиция к ускоренному восприятию гнева достоверно коррелирует с высокой личностной тревожностью, сниженными фоновыми концентрациями тромбоцитов плазмы крови, повышенной тонической активированностью коры головного мозга (по данным сниженной δ-, θ- и β1-мощности ЭЭГ в передней, центральной и задней коре больших полушарий), а также ассоциирована с более высокой стресс-реактивностью артериального давления в условиях конфронтации с осознаваемой угрозой. Выводы: с учетом установленных ассоциаций индивидов с ускоренным захватом неосознаваемой угрозы можно рассматривать как потенциальную группу риска развития индуцированной эмоциональным стрессом артериальной гипертонии, а соответствующую перцептивную предиспозицию — в качестве возможного персонифицированного поведенческого предиктора предиктора такого риска

    Nonlinear optical spectroscopy of epitaxial magnetic garnet films

    No full text
    Second and third harmonic optical spectra are studied in epitaxial magnetic thin films in the spectral ranges 1.7-3.2 eV and 2.4-4.2 eV, respectively. No significant increase of the intensity of the nonlinear spectra is found above the bandgap near 3.2 eV, where the linear absorption increases by two orders of magnitude. Large magnetic contributions to the second harmonic spectra and magnetic contrast as high as 100% are observed at selected photon energies. Contrary to that, no magnetic contribution to the third harmonic spectra is found

    Хирургическое лечение пациентов с патологией коленного сустава и деформациями нижних конечностей: систематический обзор литературы

    Get PDF
    Background. In patients with knee pathology, a phased approach to surgical treatment is often used: first, corrective osteotomies and then, if necessary, arthroplasty. This technique allows achieving optimal results of treatment. The study aimed to determine promising methods of surgical treatment of patients with knee pathology and deformities of the lower limb axis. Material and Methods. Publication search was conducted in the databases of eLibrary, PubMed, and Scopus from 2000 to 2020 (a search period of 20 years) using the following keywords: deformity of the lower limb axis, deformity correction, and total knee arthroplasty. Demographic data of the patients, features of surgical techniques, and treatment results were analyzed. Results. The literature search identified 1,232 publications, of which 12 studies that analyzed a total of 2.428 patients were included in this review. The surgical treatment covered the period from 1987 to 2018. The average follow-up period was 64.17.4 months, the average patient age was 58.81.4 years, the average duration of surgery was 114.23.9 min, and the average volume of blood loss was 484.030.0 mL. The fixation period with a metal plate, from the moment of osteotomy to hardware removal, was on average 18.01.8 months. Conclusion. Corrective osteotomies can prevent or delay knee replacement by an average of 11.8 years. Osteotomy preceding total arthroplasty does not negatively affect the survival of endoprosthesis, and its results are comparable with the medium- and long-term results of primary arthroplasty.Актуальность. У пациентов с патологией коленного сустава часто используется этапный подход к хирургическому лечению: сначала корригирующие остеотомии, а затем, при необходимости эндопротезирование. Такая тактика позволяет добиться оптимальных конечных результатов лечения. Целью данного обзора является определение перспективных способов хирургического лечения пациентов с патологией коленного сустава в сочетании с деформациями оси нижней конечности. Материал и методы. Поиск публикаций проводили в базах данных eLIBRARY, PubMed и Scopus с глубиной поиска 20 лет (с 2000 по 2020 г.) по ключевым словосочетаниям: деформация оси конечности (deformity of the lower limb axis), корригирующая остеотомия (deformity correction), тотальное эндопротезирование коленного сустава (total knee arthroplasty). Были проанализированы демографические данные пациентов, особенности хирургических вмешательств и результаты лечения. Результаты. По результатам поиска было найдено 1232 публикации, для анализа отобрано 12 исследований, в которые вошли 2428 пациентов. Сроки оперативного лечения пациентов охватили период с 1987 по 2018 г. Срок наблюдения составил в среднем 64,17,4 мес., средний возраст пациентов составил 58,81,4 года, средняя продолжительность операции 114,23,9 мин., средний объем кровопотери 484,030,0 мл. Время фиксации металлоконструкцией, прошедшее от момента остеотомии до удаления, составило в среднем 18,01,8 мес. Заключение. Корригирующие остеотомии могут предотвратить эндопротезирование или отсрочить его в среднем на 11,8 лет. Остеотомия, предшествующая тотальному эндопротезированию, не оказывает отрицательного влияния на выживаемость эндопротеза, ее результаты сопоставимы со среднесрочными и долгосрочными результатами первичного эндопротезирования

    Раскол керамического вкладыша эндопротеза тазобедренного сустава: клинический случай

    Get PDF
    Background. Ceramic component fracture is a severe complication of primary and revision total hip arthroplasty, leading to multiple revision surgeries. Case report. This report of rare clinical case of ceramic liner fracture. Fifteen months after a planned left hip replacement, the patient experienced anterior surface pain in the area of the operated joint accompanied by creaking, so the patient went for a consultation. Based on the results of the consultation, the patient was urgently hospitalized and underwent a delayed surgery for revision arthroplasty. Radiologically, there was varus position of the femoral component, dislocation of the bearings. MSCT showed ceramic liner fracture and fragment dislocation. Intraoperatively, the multifragmentary fracture of the liner, significant damage to the head, and retroversion of the acetabular component (retroversion was detected on the preoperative CT scan) were identified. All components of the endoprosthesis and tribologic bearings were replaced with identical ones, total synovectomy was performed, and the wound was cleaned and sanitized. Conclusion. The presented case report demonstrates the danger of incorrect positioning of the components when using a ceramic bearings. In this case, retroversion of the acetabular component and varus position of the femoral component resulted in a reduced contact area between the head and the liner, which caused the ceramic to fracture. The described observation confirms the need for further in-depth study of the ceramic bearings in order to prevent ceramic component fracture, as it leads to severe complications and significant economic costs.Актуальность. Раскол керамических компонентов является тяжелым осложнением первичного и ревизионного тотального эндопротезирования тазобедренного сустава, приводящим к многократным ревизионным операциям. Описание клинического наблюдения. Представляем редкий клинический случай раскола керамического вкладыша. Через 15 мес. после проведения планового эндопротезирования левого тазобедренного сустава у пациента появились боли по передней поверхности в области оперированного сустава, сопровождающиеся скрипами, вследствие чего пациент обратился за медицинской помощью. По результатам консультации пациент был экстренно госпитализирован и прооперирован в отсроченном порядке в объеме ревизионного эндопротезирования. Рентгенологически отмечались варусное положение бедренного компонента, дислокация пары трения. По данным МСКТ выявлены раскол керамического вкладыша и дислокация фрагментов. Интраоперационно обнаружены мультифрагментарный раскол вкладыша, значительное повреждение головки. На дооперационной КТ была выявлена ретроверсия вертлужного компонента. Выполнены замена всех компонентов эндопротеза и трибологической пары на идентичную, тотальная синовэктомия, рана промыта и санирована. Заключение. Представленный клинический случай демонстрирует опасность неправильного положения компонентов при использовании керамической пары трения. В приведенном наблюдении ретроверсия вертлужного компонента и варусное положение бедренного компонента привели к уменьшению площади контакта головки и вкладыша, что повлияло на раскол керамики. Описанное наблюдение подтверждает необходимость дальнейшего изучения керамической пары трения с целью профилактики раскола керамических компонентов, так как это приводит к тяжелым осложнениям и значительным экономическим затратам
    corecore