1,405 research outputs found

    Complete genome sequence of Syntrophobacter fumaroxidans strain (MPOB(T)).

    Get PDF
    Syntrophobacter fumaroxidans strain MPOB(T) is the best-studied species of the genus Syntrophobacter. The species is of interest because of its anaerobic syntrophic lifestyle, its involvement in the conversion of propionate to acetate, H2 and CO2 during the overall degradation of organic matter, and its release of products that serve as substrates for other microorganisms. The strain is able to ferment fumarate in pure culture to CO2 and succinate, and is also able to grow as a sulfate reducer with propionate as an electron donor. This is the first complete genome sequence of a member of the genus Syntrophobacter and a member genus in the family Syntrophobacteraceae. Here we describe the features of this organism, together with the complete genome sequence and annotation. The 4,990,251 bp long genome with its 4,098 protein-coding and 81 RNA genes is a part of the Microbial Genome Program (MGP) and the Genomes to Life (GTL) Program project

    Classes of depression symptom trajectories in patients with major depression receiving a collaborative care intervention

    Get PDF
    Purpose Collaborative care is effective in improving symptoms of patients with depression. The aims of this study were to characterize symptom trajectories in patients with major depression during one year of collaborative care and to explore associations between baseline characteristics and symptom trajectories. Methods We conducted a cluster-randomized controlled trial in primary care. The collaborative care intervention comprised case management and behavioral activation. We used the Patient Health Questionnaire-9 (PHQ-9) to assess symptom severity as the primary outcome. Statistical analyses comprised latent growth mixture modeling and a hierarchical binary logistic regression model. Results We included 74 practices and 626 patients (310 intervention and 316 control recipients) at baseline. Based on a minimum of 12 measurement points for each intervention recipient, we identified two latent trajectories, which we labeled \u27fast improvers\u27 (60.5%) and \u27slow improvers\u27 (39.5%). At all measurements after baseline, \u27fast improvers\u27 presented higher PHQ mean values than \u27slow improvers\u27. At baseline, \u27fast improvers\u27 presented fewer physical conditions, higher health-related quality of life, and had made fewer suicide attempts in their history. Conclusions A notable proportion of 39.5% of patients improved only \u27slowly\u27 and probably needed more intense treatment. The third follow-up in month two could well be a sensible time to adjust treatment to support \u27slow improvers\u27. (DIPF/Orig.

    Quality of life after on-pump and off-pump coronary artery bypass grafting surgery

    Get PDF
    FUNDAMENTO: Técnicas de cirurgia de revascularização miocárdica (RM) sem o uso de circulação extracorpórea (CEC) possibilitou resultados operatórios com menor dano sistêmico, menor ocorrência de complicações clínicas, menor permanência na sala de terapia intensiva e também no tempo de internação, gerando expectativas de melhor qualidade de vida (QV) dos pacientes. OBJETIVO: Avaliar a QV em pacientes submetidos à cirurgia de revascularização com e sem CEC. MÉTODOS: Em pacientes com doença multiarterial coronariana (DAC) estável e função ventricular preservada, aplicou-se o Short-Form Health Survey (SF-36) Questionnaire antes da cirurgia e depois de 6 e 12 meses. RESULTADOS: Entre janeiro de 2002 e dezembro de 2006, foram randomizados 202 pacientes para cirurgia de RM. As características demográficas clínicas laboratoriais e angiográficas foram semelhantes nos dois grupos. Desses pacientes, 105 foram operados sem CEC e 97 com CEC. Na evolução, 22 pacientes sofreram infarto, 29 relataram angina, um reoperou, 3 tiveram AVC e nenhum morreu. A avaliação da QV mostrou similaridade nos dois grupos em relação ao componente físico e mental. Todavia, encontrou-se significativa melhora da capacidade funcional e percepção do aspecto físico nos pacientes do sexo masculino. Além disso, um expressivo número de pacientes dos dois grupos retornou ao trabalho. CONCLUSÃO: Em todos os pacientes estudados, observaram-se melhora progressiva da qualidade de vida e retorno precoce ao trabalho, independentemente da técnica cirúrgica empregada. Exceto pela melhor percepção da capacidade funcional e do aspecto físico experimentado pelos homens, não houve diferença estatística nos resultados dos demais domínios alcançados pelos dois grupos estudados.BACKGROUND: Coronary artery bypass grafting techniques without using cardiopulmonary bypass (off-pump CABG) result in less systemic damage, less clinical complications, less time spent in the intensive care unit, and shorter hospital stays, thereby raising the perspective of improved quality of life (QOL) for patients. OBJECTIVE: To assess quality of life in patients who underwent on-pump and off-pump CABG. METHODS: The Short-Form Health Survey (SF-36) Questionnaire was administered to patients with stable multivessel coronary artery disease (CAD) and preserved ventricular function before and at six and 12 months after surgery. RESULTS: Between January 2002 and December 2006, a total of 202 patients were randomized to either on-pump or off-pump CABG. Demographic, clinical, laboratory, and angiographic characteristics were similar in both groups. One hundred and five patients underwent off-pump CABG and 97 underwent on-pump CABG. In the postoperative course, 22 patients had myocardial infarction, 29 reported angina, one was reoperated, and three experienced stroke. No patient died. Quality of life, as measured by the SF-36 questionnaire, was shown to be similar in both groups regarding physical and mental components. However, male patients showed a significant improvement in physical functioning and role limitations due to physical problems. Also, a large number of patients in both groups returned to work. CONCLUSION: Progressive enhancement in quality of life and early return to work were observed for all patients, regardless of the surgical technique used. Save for a greater improvement in physical functioning and role limitations due to physical problems experienced by male patients, no statistically significant differences were found in the other domains between groups

    Charge Collection and Electrical Characterization of Neutron Irradiated Silicon Pad Detectors for the CMS High Granularity Calorimeter

    Full text link
    The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-μm\mu\textrm{m} thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about 1016 neqcm−210^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 ∘^\circC to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 ∘^\circC. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60%\% or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90%\% at the lowest fluence, at 600 V. The collected charge close to the fluence of 1016 neqcm−210^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2} exceeds 1 fC at voltages beyond 800 V.Comment: 36 pages, 34 figure
    • …
    corecore