37 research outputs found

    Effect of surgery, delivery device and head position on sinus irrigant penetration in a cadaver model

    Get PDF
    AbstractObjectiveThe extent of surgery, the type of device used and head position may influence nasal irrigation. The aim of this study was to determine the effectiveness of topical irrigant delivery to the paranasal sinuses according to these factors.MethodFour cadaveric heads underwent four stepwise endoscopic dissections. Irrigations were evaluated after every stage using different delivery devices (squeeze-bottle, gravity-dependent device and syringe) in two head positions (nose-to-sink and vertex down). Irrigant penetration into each sinus was estimated using a four-point scale.ResultsA significant positive effect of surgery was demonstrated for each sinus as well as for the delivery device. High-volume irrigant devices are more effective, and the head position plays a significant role in irrigant distribution to the frontal sinus.ConclusionThis study further confirms the efficacy of high-volume irrigant devices. A vertex down position during the irrigation could improve delivery to the frontal sinus, and the widening of the ostia increases irrigant access to the sinuses

    Implicit learning deficit in children with Duchenne muscular dystrophy: Evidence for a cerebellar cognitive impairment?

    Get PDF
    This study aimed at comparing implicit sequence learning in individuals affected by Duchenne Muscular Dystrophy without intellectual disability and age-matched typically developing children. A modified version of the Serial Reaction Time task was administered to 32 Duchenne children and 37 controls of comparable chronological age. The Duchenne group showed a reduced rate of implicit learning even if in the absence of global intellectual disability. This finding provides further evidence of the involvement of specific aspects of cognitive function in Duchenne muscular dystrophy and on its possible neurobiological substrate

    Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Several cases of tibial post breakage are reported in the literature. To the best of our knowledge, only three cases of NexGen knee prosthesis (Zimmer, Warsaw, Indiana, USA) tibial post failure have been reported.</p> <p>Case presentation</p> <p>In November 1999, a 63-year-old Caucasian woman from Italy with a history of symptomatic left knee osteoarthritis underwent a total knee arthroplasty. In March 2008, while rising from a chair, she felt a sudden pain and instability in her left knee. She reported a fracture of the polyethylene post of the tibial insert. No malposition or malalignment of either the femoral or tibial components were identified. The polyethylene tibial insert was studied under light microscopy and scanning electron microscopy. The fracture was also noted to have occurred without any notable polyethylene wear.</p> <p>Conclusion</p> <p>Scanning electron microscopy revealed two different damage patterns that could be explained with a two-stage rupture of our patient's polyethylene post. This could have been caused by a non-optimal ligamentous balancing during first implant surgery. Her knee probably developed a varus instability that weakened the post, and then a posterior anterior stress finally broke the polyethylene.</p

    Research and Design of a Routing Protocol in Large-Scale Wireless Sensor Networks

    Get PDF
    无线传感器网络,作为全球未来十大技术之一,集成了传感器技术、嵌入式计算技术、分布式信息处理和自组织网技术,可实时感知、采集、处理、传输网络分布区域内的各种信息数据,在军事国防、生物医疗、环境监测、抢险救灾、防恐反恐、危险区域远程控制等领域具有十分广阔的应用前景。 本文研究分析了无线传感器网络的已有路由协议,并针对大规模的无线传感器网络设计了一种树状路由协议,它根据节点地址信息来形成路由,从而简化了复杂繁冗的路由表查找和维护,节省了不必要的开销,提高了路由效率,实现了快速有效的数据传输。 为支持此路由协议本文提出了一种自适应动态地址分配算——ADAR(AdaptiveDynamicAddre...As one of the ten high technologies in the future, wireless sensor network, which is the integration of micro-sensors, embedded computing, modern network and Ad Hoc technologies, can apperceive, collect, process and transmit various information data within the region. It can be used in military defense, biomedical, environmental monitoring, disaster relief, counter-terrorism, remote control of haz...学位:工学硕士院系专业:信息科学与技术学院通信工程系_通信与信息系统学号:2332007115216

    Posterolateral rotatory instability of the knee after arthroscopic subtotal lateral meniscectomy: a case report

    Get PDF
    Posterolateral rotatory instability of the knee after arthroscopic subtotal lateral meniscectomy: a case repor

    Long-term outcomes of medial CMI implant versus partial medial meniscectomy in patients with concomitant ACL reconstruction

    No full text
    PURPOSE: To compare the clinical, objective and radiographic long-term results of patients with anterior cruciate ligament (ACL) lesion and partial medial meniscus defects, treated with ACL reconstruction and partial medial meniscectomy or medial CMI implant. METHODS: Seventeen patients treated with combined ACL reconstruction and medial CMI and 17 patients treated with ACL reconstruction and partial medial meniscectomy were evaluated with mean follow-up 9.6 years with Lysholm, Tegner, objective and subjective International Knee Documentation Committee scores, and VAS for pain. Arthrometric evaluation was performed with KT 2000. Weigh-bearing radiographs, antero-posterior and Rosenberg view, were also performed and evaluated with Kellgren-Lawrence score, Ahlback score and joint space narrowing. RESULTS: Pre-operative demographic parameters and clinical scores between patients treated with CMI and partial medial meniscectomy revealed no significant differences. A significant improvement of all the clinical scores was detected in both groups from pre-operative status to final follow-up. No significant difference between groups were found for clinical and radiographic scores; however, the chronic subgroup of patients treated with CMI showed a significantly lower level of post-operative knee pain compared to patients treated with partial medial meniscectomy and the acute subgroup of medial CMI showed better arthrometric scores. CONCLUSION: Good long-term clinical results in terms of stability, subjective outcomes and objective evaluation were reported both for medial CMI implant and partial medial meniscectomy, combined with ACL reconstruction for the treatment of partial medial meniscus tears combined with ACL lesions. Chronic meniscal tears treated with medial CMI reported lower levels of post-operative pain compared to meniscectomy, while acute lesions treated with medial CMI showed less knee laxity. Therefore, the use of the collagen meniscus implant in the case of anterior knee instability with a meniscal defect appears justified and able to improve clinical outcomes in the long term. LEVEL OF EVIDENCE: Retrospective comparative study, Level III

    Arthroscopic autologous chondrocyte implantation for the treatment of chondral defects in the tibial plateau.

    No full text
    4The matrix-induced autologous chondrocyte implantation (MACI) is a tissue engineering technique which requires the use of a collagen membrane on which the cultured chondrocytes are seeded. We report the arthroscopic MACI technique for the treatment of chondral defects interesting lateral tibial plate of the knee. The implantation procedure was performed on two male patients affected by traumatic chondral lesions, sized respectively 2.5 and 2 cm2. The procedures were performed through traditional artrhoscopic portals and the seeded membrane was fixed with fibrin glue. Clinical-functional evaluation was performed according to ICRS score, modified Cincinnati knee score, IKDC, Lysholm II and Tegner scales. MRIs were taken 6, 12 and 24 months postoperatively. After two year all the clinical scores were improved in both patients. MRI showed filling of the defects with hyaline-like tissue with reduction of subchondral bone edema and restoration of a regular articular surface. Even though the MACI technique is mostly performed with an open procedure, the site of these lesions could not be reached without sacrifying tendinous and ligamentous structures of the knee. The arthroscopic approach allowed to achieve an optimal view of the lesion and appeared the best solution for these patients. The size of these defects was too large for bone marrow stimulation techniques and/or osteochondral grafts to be successful. The use of fibrin glue for fixating the seeded membrane has made possible to perform the procedure arthroscopically in a simple and safe way. No specifically designed instruments were used in these cases.noneRonga M.; Bulgheroni P.; Grassi F.; Cherubino P.Ronga, Mario; Bulgheroni, P.; Grassi, F.; Cherubino, Paol
    corecore