148 research outputs found

    Test Characteristics of Urinary Lipoarabinomannan and Predictors of Mortality among Hospitalized HIV-Infected Tuberculosis Suspects in Tanzania.

    Get PDF
    Tuberculosis is the most common cause of death among patients with HIV infection living in tuberculosis endemic countries, but many cases are not diagnosed pre-mortem. We assessed the test characteristics of urinary lipoarabinomannan (LAM) and predictors of mortality among HIV-associated tuberculosis suspects in Tanzania. We prospectively enrolled hospitalized HIV-infected patients in Dar es Salaam, with ≥2 weeks of cough or fever, or weight loss. Subjects gave 2 mLs of urine to test for LAM using a commercially available ELISA, ≥2 sputum specimens for concentrated AFB smear and solid media culture, and 40 mLs of blood for culture. Among 212 evaluable subjects, 143 (68%) were female; mean age was 36 years; and the median CD4 count 86 cells/mm(3). 69 subjects (33%) had culture confirmation of tuberculosis and 65 (31%) were LAM positive. For 69 cases of sputum or blood culture-confirmed tuberculosis, LAM sensitivity was 65% and specificity 86% compared to 36% and 98% for sputum smear. LAM test characteristics were not different in patients with bacteremia but showed higher sensitivity and lower specificity with decreasing CD4 cell count. Two month mortality was 64 (53%) of 121 with outcomes available. In multivariate analysis there was significant association of mortality with absence of anti-retroviral therapy (p = 0.004) and a trend toward association with a positive urine LAM (p = 0.16). Among culture-negative patients mortality was 9 (75%) of 12 in LAM positive patients and 27 (38%) of 71 in LAM negative patients (p = 0.02). Urine LAM is more sensitive than sputum smear and has utility for the rapid diagnosis of culture-confirmed tuberculosis in this high-risk population. Mortality data raise the possibility that urine LAM may also be a marker for culture-negative tuberculosis

    Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

    Get PDF
    Background: Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel wall than a stented one, even if stenosis is present. Therefore, duplex ultrasound cut-off criteria for the degrees of an in-stent stenosis, based on blood velocity parameters, are probably different from the established cut-offs used for un-stented arteries. Routine criteria can not be applied to stented arteries but new criteria need to be established for this particular purpose. Methods/Design: Current literature was systematically reviewed. From the selected studies, the following data were extracted: publication year, population size, whether the study was prospective, which reference test was used, and if there was an indication for selection bias and for verification bias in particular. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. Results: In general, the cut-off values are higher than those reported for unstented arteries. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. Discussion: To address the deficiencies of the existing studies, we propose a prospective cohort study nested within the International Carotid Stenting Study (ICSS), an international multi-centre trial in which over 1,700 patients have been randomised between stenting and CEA. In this cohort we will enrol a minimum of 300 patients treated with a stent. All patients undergo regular DUS examination at the yearly follow-up visit according to the ICSS protocol. To avoid verification bias, an additional computed tomography angiography (CTA) will be performed as a reference test in all consecutive patients, regardless of the degree of stenosis on the initial DUS test

    How does study quality affect the results of a diagnostic meta-analysis?

    Get PDF
    Background: The use of systematic literature review to inform evidence based practice in diagnostics is rapidly expanding. Although the primary diagnostic literature is extensive, studies are often of low methodological quality or poorly reported. There has been no rigorously evaluated, evidence based tool to assess the methodological quality of diagnostic studies. The primary objective of this study was to determine the extent to which variations in the quality of primary studies impact the results of a diagnostic meta-analysis and whether this differs with diagnostic test type. A secondary objective was to contribute to the evaluation of QUADAS, an evidence-based tool for the assessment of quality in diagnostic accuracy studies. Methods: This study was conducted as part of large systematic review of tests used in the diagnosis and further investigation of urinary tract infection (UTI) in children. All studies included in this review were assessed using QUADAS, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. The impact of individual components of QUADAS on a summary measure of diagnostic accuracy was investigated using regression analysis. The review divided the diagnosis and further investigation of UTI into the following three clinical stages: diagnosis of UTI, localisation of infection, and further investigation of the UTI. Each stage used different types of diagnostic test, which were considered to involve different quality concerns. Results: Many of the studies included in our review were poorly reported. The proportion of QUADAS items fulfilled was similar for studies in different sections of the review. However, as might be expected, the individual items fulfilled differed between the three clinical stages. Regression analysis found that different items showed a strong association with test performance for the different tests evaluated. These differences were observed both within and between the three clinical stages assessed by the review. The results of regression analyses were also affected by whether or not a weighting (by sample size) was applied. Our analysis was severely limited by the completeness of reporting and the differences between the index tests evaluated and the reference standards used to confirm diagnoses in the primary studies. Few tests were evaluated by sufficient studies to allow meaningful use of meta-analytic pooling and investigation of heterogeneity. This meant that further analysis to investigate heterogeneity could only be undertaken using a subset of studies, and that the findings are open to various interpretations. Conclusion: Further work is needed to investigate the influence of methodological quality on the results of diagnostic meta-analyses. Large data sets of well-reported primary studies are needed to address this question. Without significant improvements in the completeness of reporting of primary studies, progress in this area will be limited

    The assessment of the quality of reporting of meta-analyses in diagnostic research: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Over the last decade there have been a number of guidelines published, aimed at improving the quality of reporting in published studies and reviews. In systematic reviews this may be measured by their compliance with the PRISMA statement. This review aims to evaluate the quality of reporting in published meta-analyses of diagnostic tests, using the PRISMA statement and establish whether there has been a measurable improvement over time.</p> <p>Methods</p> <p>Eight databases were searched for reviews published prior to 31<sup>st </sup>December 2008. Studies were selected if they evaluated a diagnostic test, measured performance, searched two or more databases, stated the search terms and inclusion criteria, and used a statistical method to summarise a test's performance. Data were extracted on the review characteristics and items of the PRISMA statement. To measure the change in the quality of reporting over time, PRISMA items for two periods of equal duration were compared.</p> <p>Results</p> <p>Compliance with the PRISMA statement was generally poor: none of the reviews completely adhered to all 27 checklist items. Of the 236 meta-analyses included following selection: only 2(1%) reported the study protocol; 59(25%) reported the searches used; 76(32%) reported the results of a risk of bias assessment; and 82(35%) reported the abstract as a structured summary. Only 11 studies were published before 2000. Thus, the impact of QUOROM on the quality of reporting was not evaluated. However, the periods 2001-2004 and 2005-2008 (covering 93% of studies) were compared using relative risks (RR). There was an increase in the proportion of reviews reporting on five PRISMA items: eligibility criteria (RR 1.13, 95% CI 1.00 - 1.27); risk of bias across studies (methods) (RR 1.81, 95% CI 1.34 - 2.44); study selection results (RR 1.48, 95% CI 1.05 - 2.09); results of individual studies (RR 1.37, 95% CI 1.09 - 1.72); risk of bias across studies (results) (RR 1.65, 95% CI 1.20 - 2.25).</p> <p>Conclusion</p> <p>Although there has been an improvement in the quality of meta-analyses in diagnostic research, there are still many deficiencies in the reporting which future reviewers need to address if readers are to trust the validity of the reported findings.</p

    Euthanasia and other end-of-life decisions: a mortality follow-back study in Belgium

    Get PDF
    BACKGROUND: This study compares prevalence and types of medical end-of-life decisions between the Dutch-speaking and French-speaking communities of Belgium. This is the first nationwide study that can make these comparisons and the first measurement after implementation of the euthanasia law (2002). METHODS: We performed a mortality follow-back study in 2005-2006. Data were collected via the nationwide Sentinel Network of General Practitioners, an epidemiological surveillance system representative of all Belgian GPs.Weekly, all GPs reported the medical end-of-life decisions among all non-sudden deaths of patients in their practice. We compared the northern Dutch-speaking (60%) and southern French-speaking communities (40%) controlling for population differences. RESULTS: We analysed 1690 non-sudden deaths. An end-of-life decision with possible life-shortening effect was made in 50% of patients in the Dutch-speaking community and 41% of patients in the French-speaking community (OR 1.4; 95%CI, 1.2 to 1.8). Continuous deep sedation until death occurred in 8% and 15% respectively (OR 0.5; 95%CI, 0.4 to 0.7). Community differences regarding the prevalence of euthanasia or physician-assisted suicide were not significant.Community differences were more present among home/care home than among hospital deaths: non-treatment decisions with explicit life-shortening intention were made more often in the Dutch-speaking than in the French-speaking community settings (OR 2.2; 95%CI, 1.2 to 3.9); while continuous deep sedation occurred less often in the Dutch-speaking community settings (OR 0.5; 95%CI, 0.3 to 0.9). CONCLUSION: Even though legal and general healthcare systems are the same for the whole country, there are considerable variations between the communities in type and prevalence of certain end-of-life decisions, even after controlling for population difference

    Accuracy of Doppler-Echocardiographic Mean Pulmonary Artery Pressure for Diagnosis of Pulmonary Hypertension

    Get PDF
    Background: The validity of Doppler echocardiographic (DE) measurement of systolic pulmonary artery pressure (sPAP) has been questioned. Recent studies suggest that mean pulmonary artery pressure (mPAP) might reflect more accurately the invasive pressures. Methodology/Principal Findings: 241 patients were prospectively studied to evaluate the diagnostic accuracy of mPAP for the diagnosis of PH. Right heart catheterization (RHC) and DE were performed in 164 patients mainly for preoperative evaluation of heart valve dysfunction. The correlation between DE and RHC was better when mPAP (r = 0.93) and not sPAP (r = 0.81) was assessed. Bland-Altman analysis revealed a smaller variation of mPAP than sPAP. The following ROC analysis identified that a mPAP$25.5 mmHg is useful for the diagnosis of PH. This value was validated in an independent cohort of patients (n = 50) with the suspicion of chronic-thromboembolic pulmonary hypertension. The calculated diagnostic accuracy was 98%, based on excellent sensitivity of 98 % and specificity of 100%. The corresponding positive and negative predictive values were 100%, respectively 88%. Conclusion: mPAP has been found to be highly accurate for the initial diagnosis of PH. A cut-off value of 25.5 mmHg might be helpful to avoid unnecessary RHC and select patients in whom RHC might be beneficial

    Dipstick Test for Rapid Diagnosis of Shigella dysenteriae 1 in Bacterial Cultures and Its Potential Use on Stool Samples

    Get PDF
    International audienceBACKGROUND: We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. METHODOLOGY/PRINCIPAL FINDINGS: The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS) using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×10⁶ CFU/ml and 4.9×10⁶ CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316) was 98.7% (95% CI:96.6-99.6%) and the sensitivity (11/12) was 91.7% (95% CI:59.8-99.6%). Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328) in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8-91.1%) and 99.7% (95% CI:98-100%). CONCLUSION: The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys

    Preventing preterm birth with progesterone: costs and effects of screening low risk women with a singleton pregnancy for short cervical length, the Triple P study

    Get PDF
    Contains fulltext : 97255.pdf (postprint version ) (Open Access)BACKGROUND: Women with a short cervical length in mid-trimester pregnancy have a higher risk of preterm birth and therefore a higher rate of neonatal mortality and morbidity. Progesterone can potentially decrease the number of preterm births and lower neonatal mortality and morbidity. Previous studies showed good results of progesterone in women with either a history of preterm birth or a short cervix. However, it is unknown whether screening for a short cervix and subsequent treatment in mid trimester pregnancy is effective in low risk women. METHODS/DESIGN: We plan a combined screen and treat study among women with a singleton pregnancy without a previous preterm birth. In these women, we will measure cervical length at the standard anomaly scan performed between 18 and 22 weeks. Women with cervical length </= 30 mm at two independent measurements will be randomly allocated to receive either vaginal progesterone tablets or placebo between 22 and 34 weeks. The primary outcome of this trial is adverse neonatal condition, defined as a composite outcome of neonatal mortality and severe morbidity. Secondary outcomes are time to delivery, preterm birth rate before 32, 34 and 37 weeks, days of admission in neonatal intensive care unit, maternal morbidity, maternal admission days for preterm labour and costs. We will assess growth, physical condition and neurodevelopmental outcome of the children at two years of age. DISCUSSION: This study will provide evidence for the usefulness and cost-effectiveness of screening for short cervical length at the 18-22 weeks and subsequent progesterone treatment among low risk women. TRIAL REGISTRATION: Netherlands Trial Register (NTR): NTR207

    Diagnostic accuracy of non-invasive tests to screen for at-risk MASH—An individual participant data meta-analysis

    Get PDF
    \ua9 2024 The Authors. Liver International published by John Wiley &amp; Sons Ltd.Background &amp; Aims: There is a need to reduce the screen failure rate (SFR) in metabolic dysfunction-associated steatohepatitis (MASH) clinical trials (MASH+F2-3; MASH+F4) and identify people with high-risk MASH (MASH+F2-4) in clinical practice. We aimed to evaluate non-invasive tests (NITs) screening approaches for these target conditions. Methods: This was an individual participant data meta-analysis for the performance of NITs against liver biopsy for MASH+F2-4, MASH+F2-3 and MASH+F4. Index tests were the FibroScan-AST (FAST) score, liver stiffness measured using vibration-controlled transient elastography (LSM-VCTE), the fibrosis-4 score (FIB-4) and the NAFLD fibrosis score (NFS). Area under the receiver operating characteristics curve (AUROC) and thresholds including those that achieved 34% SFR were reported. Results: We included 2281 unique cases. The prevalence of MASH+F2-4, MASH+F2-3 and MASH+F4 was 31%, 24% and 7%, respectively. Area under the receiver operating characteristics curves for MASH+F2-4 were.78,.75,.68 and.57 for FAST, LSM-VCTE, FIB-4 and NFS. Area under the receiver operating characteristics curves for MASH+F2-3 were.73,.67,.60,.58 for FAST, LSM-VCTE, FIB-4 and NFS. Area under the receiver operating characteristics curves for MASH+F4 were.79,.84,.81,.76 for FAST, LSM-VCTE, FIB-4 and NFS. The sequential combination of FIB-4 and LSM-VCTE for the detection of MASH+F2-3 with threshold of.7 and 3.48, and 5.9 and 20 kPa achieved SFR of 67% and sensitivity of 60%, detecting 15 true positive cases from a theoretical group of 100 participants at the prevalence of 24%. Conclusions: Sequential combinations of NITs do not compromise diagnostic performance and may reduce resource utilisation through the need of fewer LSM-VCTE examinations

    CT colonography with limited bowel preparation for the detection of colorectal neoplasia in an FOBT positive screening population

    Get PDF
    Item does not contain fulltextPURPOSE: Aim was to evaluate the accuracy of computed tomography colonography (CTC) for detection of colorectal neoplasia in a Fecal Occult Blood Test (FOBT) positive screening population. METHODS: In three different institutions, consecutive FOBT positives underwent CTC after laxative free iodine tagging bowel preparation followed by colonoscopy with segmental unblinding. Each CTC was read by two experienced observers. For CTC and for colonoscopy the per-polyp sensitivity and per-patient sensitivity and specificity were calculated for detection of carcinomas, advanced adenomas, and adenomas. RESULTS: In total 22 of 302 included FOBT positive participants had a carcinoma (7%) and 137 had an adenoma or carcinoma >/=10 mm (45%). CTC sensitivity for carcinoma was 95% with one rectal carcinoma as false negative finding. CTC sensitivity for advanced adenomas was 92% (95% CI: 88-96) vs. 96% (95% CI: 93-99) for colonoscopy (P = 0.26). For adenomas and carcinomas >/=10 mm the CTC per-polyp sensitivity was 93% (95% CI: 89-97) vs. 97% (95% CI: 94-99) for colonoscopy (P = 0.17). The per-patient sensitivity for the detection of adenomas and carcinomas >/=10 mm was 95% (95% CI: 91-99) for CTC vs. 99% (95% CI: 98-100) for colonoscopy (P = 0.07), while the per-patient specificity was 90% (95% CI: 86-95) and 96% (95% CI: 94-99), respectively (P < 0.001). CONCLUSION: CTC with limited bowel preparation performed in an FOBT positive screening population has high diagnostic accuracy for the detection of adenomas and carcinomas and a sensitivity similar to that of colonoscopy for relevant lesions.1 december 201
    corecore