51 research outputs found

    Reclaiming the periphery: Automated kinetic perimetry for measuring peripheral visual fields in patients with glaucoma

    Get PDF
    Purpose: Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Methods: Thirty patients with glaucoma (median age 68, range 59–83 years; median Mean Deviation −8.0, range −16.3–0.1 dB) performed AKP and static automated perimetry (SAP) (German Adaptive Threshold Estimation strategy, 24-2 test). Automated kinetic perimetry consisted of a fully automated measurement of a single isopter (III.1.e). Central and peripheral visual fields were measured twice on the same day. Results: Peripheral and central visual fields were only moderately related (Spearman's ρ, 0.51). Approximately 90% of test-retest differences in mean isopter radius were < ±4 deg. Relative to the range of measurements in this sample, the retest variability of AKP was similar to that of SAP. Conclusions: Patients with similar central visual field loss can have strikingly different peripheral visual fields, and therefore measuring the peripheral visual field may add clinically valuable information

    The Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V.

    Get PDF
    Purpose: It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect of censoring on mean deviation (MD). Methods: In the Iowa Variability in Perimetry Study, 120 glaucoma subjects were tested every 6 months for 4 years with size III SITA Standard and size V Full Threshold. Progression was determined with three complementary techniques: pointwise linear regression (PLR), permutation of PLR, and linear regression of the MD index. All analyses were repeated on "censored'' datasets in which threshold estimates below a given criterion value were set to equal the criterion value. Results: Our analyses confirmed previous observations that threshold estimates below 20 dB contribute much less to visual field progression than estimates above this range. These findings were broadly similar with stimulus sizes III and V. Conclusions: Censoring of threshold values < 20 dB has relatively little impact on the rates of visual field progression in patients with mild to moderate glaucoma. Size V, which has lower retest variability, performs at least as well as size III for longitudinal glaucoma progression analysis and appears to have a larger useful dynamic range owing to the upper sensitivity limit being higher

    Visual Field Progression in Glaucoma: Comparison Between PoPLR and ANSWERS

    Get PDF
    Purpose: It has been suggested that the detection of visual field progression can be improved by modeling statistical properties of the data such as the increasing retest variability and the spatial correlation among visual field locations. We compared a method that models those properties, Analysis with Non-Stationary Weibull Error Regression and Spatial Enhancement (ANSWERS), against a simpler one that does not, Permutation of Pointwise Linear Regression (PoPLR). Methods: Visual field series from three independent longitudinal studies in patients with glaucoma were used to compare the positive rate of PoPLR and ANSWERS. To estimate the false-positive rate, the same visual field series were randomly re-ordered in time. The first dataset consisted of series of 7 visual fields from 101 eyes, the second consisted of series of 9 visual fields from 150 eyes, and the third consisted of series of more than 9 visual fields (17.5 on average) from 139 eyes. Results: For a statistical significance of 0.05, the false-positive rates for ANSWERS were about 3 times greater than expected at 15%, 17%, and 16%, respectively, whereas for PoPLR they were 7%, 3%, and 6%. After equating the specificities at 0.05 for both models, positive rates for ANSWERS were 16%, 25%, and 38%, whereas for PoPLR they were 12%, 33%, and 49%, or about 5% greater on average (95% confidence interval = -1% to 11%). Conclusions: Despite being simpler and less computationally demanding, PoPLR was at least as sensitive to deterioration as ANSWERS once the specificities were equated. Translational Relevance: Close control of false-positive rates is key when visual fields of patients are analyzed for change in both clinical practice and clinical trials

    Validation of the UNC OCT Index for the Diagnosis of Early Glaucoma

    Get PDF
    Purpose:To independently validate the performance of the University of North Carolina Optical Coherence Tomography (UNC OCT) Index in diagnosing and predicting early glaucoma. Methods:Data of 118 normal subjects (118 eyes) and 96 subjects (96 eyes) with early glaucoma defined as visual field mean deviation (MD) greater than -4 decibels (dB), aged 40 to 80 years, and who were enrolled in the Full-Threshold Testing Size III, V, VI comparison study were used in this study. CIRRUS OCT average and quadrants' retinal nerve fiber layer (RNFL); optic disc vertical cup-to-disc ratio (VCDR), cup-to-disc area ratio, and rim area; and average, minimum, and six sectoral ganglion cell-inner plexiform layer (GCIPL) measurements were run through the UNC OCT Index algorithm. Area under the receiver operating characteristic curve (AUC) and sensitivities at 95% and 99% specificity were calculated and compared between single parameters and the UNC OCT Index. Results:Mean age was 60.1 ± 11.0 years for normal subjects and 66.5 ± 8.1 years for glaucoma patients (P &lt; 0.001). MD was 0.29 ± 1.04 dB and -1.30 ± 1.35 dB in normal and glaucomatous eyes (P &lt; 0.001), respectively. The AUC of the UNC OCT Index was 0.96. The best single metrics when compared to the UNC OCT Index were VCDR (0.93, P = 0.054), average RNFL (0.92, P = 0.014), and minimum GCIPL (0.91, P = 0.009). The sensitivities at 95% and 99% specificity were 85.4% and 76.0% (UNC OCT Index), 71.9% and 62.5% (VCDR, all P &lt; 0.001), 64.6% and 53.1% (average RNFL, all P &lt; 0.001), and 66.7% and 58.3% (minimum GCIPL, all P &lt; 0.001), respectively. Conclusions:The findings confirm that the UNC OCT Index may provide improved diagnostic perforce over that of single OCT parameters and may be a good tool for detection of early glaucoma. Translational Relevance:The UNC OCT Index algorithm may be incorporated easily into routine clinical practice and be useful for detecting early glaucoma

    Validation of the UNC OCT Index for the Diagnosis of Early Glaucoma

    Get PDF
    Observations of binary stars containing an accreting black hole or neutron star often show x-ray emission extending to high energies (>10 kilo­–electron volts), which is ascribed to an accretion disk corona of energetic particles akin to those seen in the solar corona. Despite their ubiquity, the physical conditions in accretion disk coronae remain poorly constrained. Using simultaneous infrared, optical, x-ray, and radio observations of the Galactic black hole system V404 Cygni, showing a rapid synchrotron cooling event in its 2015 outburst, we present a precise 461 ± 12 gauss magnetic field measurement in the corona. This measurement is substantially lower than previous estimates for such systems, providing constraints on physical models of accretion physics in black hole and neutron star binary systems

    Data obtained with an open-source static automated perimetry test of the full visual field in healthy adults

    Get PDF
    The data were gathered from 98 eyes of 98 ocular healthy subjects. The subject ages ranged from 18 to 79 years with a mean (and standard deviation) of 47 (17) years. Each subject underwent two visual field tests, one of the central visual field (64 locations within 26° of fixation) and one of the peripheral visual field (64 locations with eccentricity from 26° to up to 81°). Luminance thresholds for the Goldmann size V stimulus (with a diameter of 1.72° of visual angle) were obtained with the ZEST Bayesian test procedure. Each test was conducted twice within 90 days

    Outcomes of gonioscopy-assisted transluminal trabeculotomy in pseudoexfoliative glaucoma: 24-month follow-up

    Get PDF
    AimTo report on outcomes of gonioscopy-assisted transluminal trabeculotomy (GATT) in eyes with pseudoexfoliative glaucoma (PXG).MethodsProspective, interventional, non-comparative case series. A total of 103 eyes from 84 patients with PXG were enrolled to undergo a 360-degree ab interno trabeculotomy with gonioscopic assistance using either a 5.0 polypropylene suture or an illuminated microcatheter with up to 24 months of follow-up. Main outcome measures were intraocular pressure (IOP), number of antiglaucoma medications, success rate (IOP reduction ≥20% from baseline or IOP between 6 and 21 mm Hg, without further glaucoma surgery) and complication rate.ResultsMean preoperative IOP was 27.1 mm Hg (95% CI 25.5 to 28.7) using 2.9 (SD 1.1) glaucoma medications which decreased postoperatively to 13.0 mm Hg (95% CI 11.5 to 14.4) and 1.0 (SD 1.1) medications at 24 months (p&lt;0.001). Success rate was 89.2% at 24 months of follow-up, and complication rate was 2.9%.ConclusionAt 24 months of follow-up, our results for GATT in PXG demonstrate that this conjunctival sparing procedure effectively lowers IOP and reduces the medications with a low complication rate, in this relatively aggressive glaucoma subtype.</jats:sec

    ISCEV and IPS guideline for the full-field stimulus test (FST)

    Get PDF
    The full-field stimulus test (FST) is a psychophysical technique designed for the measurement of visual function in low vision. The method involves the use of a ganzfeld stimulator, as used in routine full-field electroretinography, to deliver full-field flashes of light. This guideline was developed jointly by the International Society for Clinical Electrophysiology of Vision (ISCEV) and Imaging and Perimetry Society (IPS) in order to provide technical information, promote consistency of testing and reporting, and encourage convergence of methods for FST. It is intended to aid practitioners and guide the formulation of FST protocols, with a view to future standardisation

    Optimising the glaucoma signal/noise ratio by mapping changes in spatial summation with area-modulated perimetric stimuli

    Get PDF
    Identification of glaucomatous damage and progression by perimetry are limited by measurement and response variability. This study tested the hypothesis that the glaucoma damage signal/noise ratio is greater with stimuli varying in area, either solely, or simultaneously with contrast, than with conventional stimuli varying in contrast only (Goldmann III, GIII). Thirty glaucoma patients and 20 age-similar healthy controls were tested with the Method of Constant Stimuli (MOCS). One stimulus modulated in area (A), one modulated in contrast within Ricco's area (C R ), one modulated in both area and contrast simultaneously (AC), and the reference stimulus was a GIII, modulating in contrast. Stimuli were presented on a common platform with a common scale (energy). A three-stage protocol minimised artefactual MOCS slope bias that can occur due to differences in psychometric function sampling between conditions. Threshold difference from age-matched normal (total deviation), response variability, and signal/noise ratio were compared between stimuli. Total deviation was greater with, and response variability less dependent on defect depth with A, AC, and C R stimuli, compared with GIII. Both A and AC stimuli showed a significantly greater signal/noise ratio than the GIII, indicating that area-modulated stimuli offer benefits over the GIII for identifying early glaucoma and measuring progression
    corecore