5,446 research outputs found
Calibration and performance tests of the Very-Front-End electronics for the CMS electromagnetic calorimeter
The Very-Front-End electronics processing signals from photodetectors of the CMS electromagnetic calorimeter have been put through an extensive test programme to guarantee functionality and reliability. The final characteristics of the VFE boards designed for the calorimeter barrel and endcaps are presented. The results, which have been also verified during test beam at CERN, confirm the high quality of the boards production and show that the CMS detector specifications are reached
Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests
A prototype for a sampling calorimeter made out of cerium fluoride crystals
interleaved with tungsten plates, and read out by wavelength-shifting fibres,
has been exposed to beams of electrons with energies between 20 and 150 GeV,
produced by the CERN Super Proton Synchrotron accelerator complex. The
performance of the prototype is presented and compared to that of a Geant4
simulation of the apparatus. Particular emphasis is given to the response
uniformity across the channel front face, and to the prototype's energy
resolution.Comment: 6 pages, 6 figures, Submitted to NIM
Precision measurements of the total and partial widths of the psi(2S) charmonium meson with a new complementary-scan technique in antiproton-proton annihilations
We present new precision measurements of the psi(2S) total and partial widths
from excitation curves obtained in antiproton-proton annihilations by Fermilab
experiment E835 at the Antiproton Accumulator in the year 2000. A new technique
of complementary scans was developed to study narrow resonances with
stochastically cooled antiproton beams. The technique relies on precise
revolution-frequency and orbit-length measurements, while making the analysis
of the excitation curve almost independent of machine lattice parameters. We
study the psi(2S) meson through the processes pbar p -> e+ e- and pbar p ->
J/psi + X -> e+ e- + X. We measure the width to be Gamma = 290 +- 25(sta) +-
4(sys) keV and the combination of partial widths Gamma_e+e- * Gamma_pbarp /
Gamma = 579 +- 38(sta) +- 36(sys) meV, which represent the most precise
measurements to date.Comment: 17 pages, 3 figures, 3 tables. Final manuscript accepted for
publication in Phys. Lett. B. Parts of the text slightly expanded or
rearranged; results are unchange
Measurement of the branching ratio of the decay
From the 2002 data taking with a neutral kaon beam extracted from the
CERN-SPS, the NA48/1 experiment observed 97 candidates with a background contamination of events.
From this sample, the BR() is measured to be
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered
Measurement of K^0_e3 form factors
The semileptonic decay of the neutral K meson, KL -> pi e nu (Ke3), was used
to study the strangeness-changing weak interaction of hadrons. A sample of 5.6
million reconstructed events recorded by the NA48 experiment was used to
measure the Dalitz plot density. Admitting all possible Lorentz-covariant
couplings, the form factors for vector (f_+(q^2)), scalar (f_S) and tensor
(f_T) interactions were measured. The linear slope of the vector form factor
lambda_+ = 0.0284+-0.0007+-0.0013 and values for the ratios |f_S/f_+(0)| =
0.015^{+0.007}_{-0.010}+-0.012 and |f_T/f_+(0)| = 0.05^{+0.03}_{-0.04}+-0.03
were obtained. The values for f_S and f_T are consistent with zero. Assuming
only Vector-Axial vector couplings, lambda_+ = 0.0288+-0.0004+-0.0011 and a
good fit consistent with pure V-A couplings were obtained. Alternatively, a fit
to a dipole form factor yields a pole mass of M = 859+-18 MeV, consistent with
the K^*(892) mass.Comment: 16 pages, 7 figures. submitted to Phys. Lett.
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated
- …
