911 research outputs found

    Isolation of 39 polymorphic microsatellite loci and the development of a fluorescently labelled marker set for the Eurasian badger

    Get PDF
    We have isolated 78 microsatellite loci from the Eurasian badger (Meles meles). Of the 52 loci characterized, 39 were found to be polymorphic. A fluorescently labelled primer set was developed to enable individual-specific 17-locus genotypes to be obtained efficiently

    Effect of Nyquist Noise on the Nyquist Dephasing Rate in 2d Electron Systems

    Full text link
    We measure the effect of externally applied broadband Nyquist noise on the intrinsic Nyquist dephasing rate of electrons in a two-dimensional electron gas at low temperatures. Within the measurement error, the phase coherence time is unaffected by the externally applied Nyquist noise, including applied noise temperatures of up to 300 K. The amplitude of the applied Nyquist noise from 100 MHz to 10 GHz is quantitatively determined in the same experiment using a microwave network analyzer.Comment: 5 pages, 4 figures. Author affiliation clarified; acknowledgements modified. Replacement reason clarifie

    Persistence of the efficacy of copper oxide wire particles against Haemonchus contortus in grazing South African goats

    Get PDF
    A study was conducted to examine the duration of anthelmintic effect of copper oxide wire particles (COWP) in grazing goats, as data for the persistence of efficacy of COWP in this host species is limited. Forty-eight indigenous male goats were infected naturally by grazing them on Haemonchus contortus-infected pasture. When the faecal egg count (FEC) in the goats was 3179 ± 540 eggs per gram of faeces (mean ± standard error), half the animals were treated with 4 g COWP (day 0; mean live weight = 25.5 ± 0.8 kg). Eight treated (COWP) and eight non-treated (CONTROL) goats were removed from the pasture on each of days 7, 28 and 56, maintained for 27 or 29 days in concrete pens and then humanely slaughtered for nematode recovery. Mean liver copper levels were in the high range in the goats removed from pasture at day 7 (treated: 191 ± 19.7 ppm; untreated: 120 ± 19.7 ppm; P = 0.022), but had dropped to normal levels at days 28 and 56. The mean H. contortus burdens of the treated versus the non-treated goats were, respectively, 184 ± 48 and 645 ± 152 for the goats removed from pasture at day 7 (71% reduction; P = 0.004), 207 ± 42 and 331 ± 156 at day 28 (37% reduction; P = 0.945) and 336 ± 89 and 225 ± 53 at day 56 (−49% reduction; P = 0.665). Weekly monitoring of FECs after treatment until slaughter indicated that the COWP-treated goats had lower FECs than the controls, the treatment main effect being significant at days 7, 28 and 56 (P < 0.01). The day main effect and the treatment × day interaction were only significant for the goats removed from pasture at day 28 (P ≤ 0.001). Packed cell volumes increased during the course of the experiment (day, P < 0.001), but the treatment main effect was significant only for the goats removed from pasture at day 28 (CONTROL 28 d, 28.65 ± 0.52% < COWP 28 d, 31.31 ± 0.52%; P < 0.001). No differences in live weight between groups were considered to be of any practical significance. The study indicated that persistence of efficacy of COWP is limited in goats, extending at most to 28 days after treatment. However, repeated COWP administration at three-month intervals may be safe, given that liver copper levels return to normal two to three months after COWP treatment

    The potential to control Haemonchus contortus in indigenous South African goats with copper oxide wire particles

    Get PDF
    The high prevalence of resistance of Haemonchus contortus to all major anthelmintic groups has prompted investigations into alternative control methods in South Africa, including the use of copper oxide wire particle (COWP) boluses. To assess the efficacy of COWP against H. contortus in indigenous South African goats, 18 male faecal egg-count-negative goats were each given ca.1200 infective larvae of H. contortus three times per week during weeks 1 and 2 of the experiment. These animals made up an “established” infection group (ESTGRP). At the start of week 7, six goats were each given a 2-g COWP bolus orally; six goats received a 4-g COWP bolus each and six animals were not treated. A further 20 goats constituted a “developing” infection group (DEVGRP). At the beginning of week 1, seven of the DEVGRP goats were given a 2-g COWP bolus each; seven goats were treated with a 4-g COWP bolus each and no bolus was given to a further six animals. During weeks 1–6, each of these DEVGRP goats was given ca. 400 H. contortus larvae three times per week. All 38 goats were euthanized for worm recovery from the abomasa and small intestines in week 11. In the ESTGRP, the 2-g and 4-g COWP boluses reduced the worm burdens by 95% and 93%, respectively compared to controls (mean burden ± standard deviation, SD: 23 ± 33, 30 ± 56 and 442 ± 518 worms, P = 0.02). However, in the DEVGRP goats, both the 2-g and 4-g COWP treatments were ineffective in reducing the worm burdens relative to the controls (mean burdens ± SD: 1102 ± 841, 649 ± 855, 1051 ± 661 worms, P = 0.16). Mean liver copper levels did not differ between the ESTGRP goats treated with 2-g COWP, 4-g COWP or no COWP (mean ± standard error of the mean, SEM, in ppm: 93.7 ± 8.3; 101.5 ± 8.3; 71.8 ± 8.3, P = 0.07) nor did they differ between the DEVGRP goats (mean ± SEM, in ppm: 74.1 ± 9.1; 75.4 ± 9.1; 74.9 ± 10.0, P > 0.99). The copper values were considered adequate, but not high, for goats. The COWP boluses have the potential to be used in the place of conventional anthelmintics for the control of established H. contortus infections in indigenous South African goats, but their use as part of an integrated approach to control H. contortus in the field must be fully investigated

    Direct measurement of sub-pixel structure of the EPIC MOS CCD on-board th e XMM/NEWTON satellite

    Full text link
    We have used a mesh experiment in order to measure the sub-pixel structure of the EPIC MOS CCDs on-board the XMM/NEWTON satellite. The EPIC MOS CCDs have 40 μ\mum-square pixels which have an open electrode structure in order to improve the detection efficiency for low-energy X-rays. We obtained restored pixel images for various X-ray event grades (e.g. split-pixel events, single pixel events, etc.) at various X-ray energies. We confirmed that the open electrode structure results in a distorted horizontal pixel boundary. The open electrode region generates both single pixel events and vertically split events, but no horizontally split events. Because the single pixel events usually show the best energy resolution, we discuss a method of increasing the fraction of single pixel events from the open electrode region. Furthermore, we have directly measured the thickness of the electrodes and dead-layers by comparing spectra from the open electrode region with those from the other regions: electrodes, electrode finger and channel stop. We can say that EPIC MOS CCDs are more radiation hard than front-illumination chips of ACIS on-board Chandra X-ray Observatory because of their extra absorption thickness above the charge transfer channel. We calcurated the mean pixel response and found that our estimation has a good agreement with that of the ground calibration of EPIC MOS CCD.Comment: 20pages including 2 tables, 10 figures,Accepted for publication in : Nuclear Instruments and Methods in Physics Research

    High speed video capture for mobile phone cameras

    Get PDF
    We consider an electromechanical model for the operation of a voice coil motor in a mobile phone camera, with the aim of optimizing how a lens can be moved to a desired focusing motion. Although a methodology is developed for optimizing lens shift, there is some concern about the experimentally-determined model parameters that are at our disposal. Central to the model is the value of the estimated magnetic force constant, Kf: its value determines how far it is actually possible to move lens, but it appears that, from the value given, it would not be possible to shift the lens through the displacements desired. Furthermore, earlier experiments have also estimated the value of the back EMF constant, Kg , to be roughly five times greater than Kf, even though we present two theoretical arguments that show that Kf = Kg: a conclusion supported by readily-available manufacturers’ data

    Exclusive Queueing Process with Discrete Time

    Full text link
    In a recent study [C Arita, Phys. Rev. E 80, 051119 (2009)], an extension of the M/M/1 queueing process with the excluded-volume effect as in the totally asymmetric simple exclusion process (TASEP) was introduced. In this paper, we consider its discrete-time version. The update scheme we take is the parallel one. A stationary-state solution is obtained in a slightly arranged matrix product form of the discrete-time open TASEP with the parallel update. We find the phase diagram for the existence of the stationary state. The critical line which separates the parameter space into the regions with and without the stationary state can be written in terms of the stationary current of the open TASEP. We calculate the average length of the system and the average number of particles
    corecore