210 research outputs found

    Limited energy spread in an SSC

    Get PDF
    http://accelconf.web.cern.ch/AccelConf/c78/papers/f-02.pd

    Chromatic correlations at injection and related ejection problems in separated sector cyclotrons

    Get PDF
    International audienceInjection into a cyclotron, in order to preventemittance and phase spread dilution, requires propercouplings in the matching. One must first introduce aAP/r' associated with an r/AW coupling (through simplecticconditions) ; according to the angle of theaccelerating dees and the choice of harmonic numberthe(r,r') acceptance may also have to be tilted. Allthese effects are investigated in the case of theGANIL SSC's. At extraction corresponding correlationsexist. For a resonant system, extraction may be difficultwhen the energy spread is large because of thelarge coupling induced by resonance. A precessionalextraction which has been studied might in this casebe more efficient. Other ways for making extractioneasier are also considered. Moreover a new method ofphase compression at injection into the SSC is presentlyunder study at GANIL

    Bivalirudin started during emergency transport for primary PCI.

    Get PDF
    BACKGROUND: Bivalirudin, as compared with heparin and glycoprotein IIb/IIIa inhibitors, has been shown to reduce rates of bleeding and death in patients undergoing primary percutaneous coronary intervention (PCI). Whether these benefits persist in contemporary practice characterized by prehospital initiation of treatment, optional use of glycoprotein IIb/IIIa inhibitors and novel P2Y12 inhibitors, and radial-artery PCI access use is unknown. METHODS: We randomly assigned 2218 patients with ST-segment elevation myocardial infarction (STEMI) who were being transported for primary PCI to receive either bivalirudin or unfractionated or low-molecular-weight heparin with optional glycoprotein IIb/IIIa inhibitors (control group). The primary outcome at 30 days was a composite of death or major bleeding not associated with coronary-artery bypass grafting (CABG), and the principal secondary outcome was a composite of death, reinfarction, or non-CABG major bleeding. RESULTS: Bivalirudin, as compared with the control intervention, reduced the risk of the primary outcome (5.1% vs. 8.5%; relative risk, 0.60; 95% confidence interval [CI], 0.43 to 0.82; P=0.001) and the principal secondary outcome (6.6% vs. 9.2%; relative risk, 0.72; 95% CI, 0.54 to 0.96; P=0.02). Bivalirudin also reduced the risk of major bleeding (2.6% vs. 6.0%; relative risk, 0.43; 95% CI, 0.28 to 0.66; P<0.001). The risk of acute stent thrombosis was higher with bivalirudin (1.1% vs. 0.2%; relative risk, 6.11; 95% CI, 1.37 to 27.24; P=0.007). There was no significant difference in rates of death (2.9% vs. 3.1%) or reinfarction (1.7% vs. 0.9%). Results were consistent across subgroups of patients. CONCLUSIONS: Bivalirudin, started during transport for primary PCI, improved 30-day clinical outcomes with a reduction in major bleeding but with an increase in acute stent thrombosis. (Funded by the Medicines Company; EUROMAX ClinicalTrials.gov number, NCT01087723.)

    High-rate low-temperature dc pulsed magnetron sputtering of photocatalytic TiO2films: the effect of repetition frequency

    Get PDF
    The article reports on low-temperature high-rate sputtering of hydrophilic transparent TiO2thin films using dc dual magnetron (DM) sputtering in Ar + O2mixture on unheated glass substrates. The DM was operated in a bipolar asymmetric mode and was equipped with Ti(99.5) targets of 50 mm in diameter. The substrate surface temperature Tsurfmeasured by a thermostrip was less than 180 °C for all experiments. The effect of the repetition frequency frwas investigated in detail. It was found that the increase of frfrom 100 to 350 kHz leads to (a) an improvement of the efficiency of the deposition process that results in a significant increase of the deposition rate aDof sputtered TiO2films and (b) a decrease of peak pulse voltage and sustaining of the magnetron discharge at higher target power densities. It was demonstrated that several hundreds nm thick hydrophilic TiO2films can be sputtered on unheated glass substrates at aD = 80 nm/min, Tsurf < 180 °C when high value of fr = 350 kHz was used. Properties of a thin hydrophilic TiO2film deposited on a polycarbonate substrate are given

    Use of ultrasound by emergency medical services: a review

    Get PDF
    Prehospital ultrasound has been deployed in certain areas of the USA and Europe. Physicians, emergency medical technicians, and flight nurses have utilized a variety of medical and trauma ultrasound assessments to impact patient care in the field. The goal of this review is to summarize the literature on emergency medical services (EMS) use of ultrasound to more clearly define the potential utility of this technology for prehospital providers

    Use of ultrasound by emergency medical services: a review

    Get PDF
    Prehospital ultrasound has been deployed in certain areas of the USA and Europe. Physicians, emergency medical technicians, and flight nurses have utilized a variety of medical and trauma ultrasound assessments to impact patient care in the field. The goal of this review is to summarize the literature on emergency medical services (EMS) use of ultrasound to more clearly define the potential utility of this technology for prehospital providers

    Efficacy and Safety of Glycoprotein IIb/IIIa Inhibitors on Top of Ticagrelor in STEMI: A Subanalysis of the ATLANTIC Trial

    Get PDF
    BACKGROUND: Glycoprotein IIb/IIIa inhibitors (GPIs) in combination with clopidogrel improve clinical outcome in ST-elevation myocardial infarction (STEMI); however, finding a balance that minimizes both thrombotic and bleeding risk remains fundamental. The efficacy and safety of GPI in addition to ticagrelor, a more potent P2Y12-inhibitor, have not been fully investigated. METHODS: 1,630 STEMI patients who underwent primary percutaneous coronary intervention (PCI) were analyzed in this subanalysis of the ATLANTIC trial. Patients were divided in three groups: no GPI, GPI administration routinely before primary PCI, and GPI administration in bailout situations. The primary efficacy outcome was a composite of death, myocardial infarction, urgent target revascularization, and definite stent thrombosis at 30 days. The safety outcome was non-coronary artery bypass graft (CABG)-related PLATO major bleeding at 30 days. RESULTS: Compared with no GPI (n\u2009=\u2009930), routine GPI (n\u2009=\u2009525) or bailout GPI (n\u2009=\u2009175) was not associated with an improved primary efficacy outcome (4.2% no GPI vs. 4.0% routine GPI vs. 6.9% bailout GPI; p\u2009=\u20090.58). After multivariate analysis, the use of GPI in bailout situations was associated with a higher incidence of non-CABG-related bleeding compared with no GPI (odds ratio [OR] 2.96, 95% confidence interval [CI] 1.32-6.64; p\u2009=\u20090.03). However, routine GPI use compared with no GPI was not associated with a significant increase in bleeding (OR 1.78, 95% CI 0.88-3.61; p\u2009=\u20090.92). CONCLUSION: Use of GPIs in addition to ticagrelor in STEMI patients was not associated with an improvement in 30-day ischemic outcome. A significant increase in 30-day non-CABG-related PLATO major bleeding was seen in patients who received GPIs in a bailout situation

    The Role of Interferon in Hepatitis B Therapy

    Get PDF
    Despite the introduction of new nucleos(t)ide analogues in recent years, peginterferon is still recommended as a potential first-line treatment option by current practice guidelines for the management of chronic hepatitis B. Peginterferon offers the advantage of higher sustained off-treatment response rates compared to nucleos(t)ide analogues because of its immunomodulatory effects. Sustained transition to the inactive hepatitis B surface antigen (HBsAg) carrier state can be achieved in about 30% of hepatitis B e antigen (HBeAg)–positive patients and 20% of HBeAg-negative patients. Recent studies have focused on identification of pretreatment and on-treatment factors that allow the selection of patients who are likely to achieve a sustained response to peginterferon therapy in order to avoid the side-effects and costs associated with unnecessary treatment. Future studies need to address whether specific virologic benchmarks can guide individualized decisions concerning therapy continuation and whether peginterferon combined with new potent nucleos(t)ide analogues improves treatment outcomes

    Comparison of Serum HBsAg Quantitation by Four Immunoassays, and Relationships of HBsAg Level with HBV Replication and HBV Genotypes

    Get PDF
    BACKGROUND: The decline in hepatitis B virus surface antigen (HBsAg) may be an early predictor of the viral efficacy of Hepatitis B virus (HBV) therapy. The HBsAg levels obtained by different immunoassays now need comparing and the relationships between levels of HBsAg and HBV DNA alongside HBsAg and genotype must be evaluated. METHODOLOGY/PRINCIPAL FINDINGS: HBsAg levels were compared among 80 patients using the Abbott Architect assay, a commercial immunoassay approved for HBsAg detection and quantitation, and three other assays derived from immunoassays approved for HBsAg detection (manufactured by Diasorin, Bio-Rad and Roche). Good correlation was found between the Abbot vs. Diasorin, Bio-Rad and Roche assays with narrow 95% limits of agreement and small mean differences: -0.06 to 0.11, -0.09 log(10) IU/mL; -0.57 to 0.64, -0.04 log(10) IU/mL; -0.09 to 0.45, -0.27 log(10) IU/mL, respectively. These agreements were not affected by genotypes A or D. HBsAg was weakly correlated with HBV DNA, whatever the HBsAg assay used: Abbott, ρ = 0.36 p = 0.001, Diasorin ρ = 0.34, p = 0.002; Bio-Rad ρ = 0.37, p<0.001; or Roche ρ = 0.41, p<0.001. This relationship between levels of HBsAg and HBV DNA seemed to depend on genotypes. Whereas HBsAg (Abbott assay) tended to correlate with HBV DNA for genotype A (ρ = 0.44, p = 0.02), no such correlation was significant for genotypes D (ρ = 0.29, p = 0.15). CONCLUSION/SIGNIFICANCE: The quantitation of HBsAg in routine clinical samples is comparable between the reference assay and the adapted assays with acceptable accuracy limits, low levels of variability and minimum discrepancy. While HBsAg quantitation is not affected by HBV genotype, the observed association between levels of HBsAg and HBV DNA seems genotype dependent
    corecore