332 research outputs found

    Assessment and modelling of the effect of precipitated ferric chloride addition on the activated sludge settling properties

    Full text link
    [EN] This research studies the effect of the widely used coagulant ferric chloride on the activated sludge sedimentability through a vast array of hindered settling tests considering different application modes and a wide range of reagent doses. Direct application of ferric chloride improved the hindered settling velocity (up to twice the settling velocity of the activated sludge with no coagulant addition), but sharply decreased the pH to levels where the biological process was unfeasible (pH < 4). When the pH was adjusted during coagulation to avoid biological inhibition, the impact on the settling velocity depended on the adjusted pH value. When the added coagulant was previously precipitated and neutralized, no pH inhibition occurred and the hindered settling velocity increased linearly with the dose (up to 8 times). This velocity improvement was caused by the increase in flocs density due to the capture within the flocs of the formed precipitates. Based on these experimental results, the usefulness and reliability of the standard hindered settling velocity mathematical models used for the secondary settler design and optimization (Richardson & Zaki model and the Vesilind's exponential model), was expanded to situations in which precipitated ferric chloride is used in wastewater treatment plants. Two empirical equations were proposed and fitted to relate these mathematical models¿ parameters with the dose of coagulant.Asensi Dasí, EJ.; Alemany Martínez, E.; Duque-Sarango, P.; Aguado García, D. (2019). Assessment and modelling of the effect of precipitated ferric chloride addition on the activated sludge settling properties. Chemical Engineering Research and Design. 150:14-25. https://doi.org/10.1016/j.cherd.2019.07.018S142515

    Spectral characterization of laser-accelerated protons with CR-39 nuclear track detector

    Get PDF
    CR-39 nuclear track material is frequently used for the detection of protons accelerated in laser-plasma interactions. The measurement of track densities allows for determination of particle angular distributions, and information on the kinetic energy can be obtained by the use of passive absorbers. We present a precise method of measuring spectral distributions of laser-accelerated protons in a single etching and analysis process. We make use of a one-to-one relation between proton energy and track size and present a precise calibration based on monoenergetic particle beams. While this relation is limited to proton energies below 1 MeV, we show that the range of spectral measurements can be significantly extended by simultaneous use of absorbers of suitable thicknesses. Examples from laser-plasma interactions are presented, and quantitative results on proton energies and particle numbers are compared to those obtained from a time-of-flight detector. The spectrum end points of continuous energy distributions have been determined with both detector types and coincide within 50-100 keV

    Polymorphisms of Pyrimidine Pathway Enzymes Encoding Genes and HLA-B*40∶01 Carriage in Stavudine-Associated Lipodystrophy in HIV-Infected Patients

    Get PDF
    Altres ajuts: Fundación para la Investigación y Prevención del SIDA en España (FIPSE 36610, 36572/06); Red de Investigación en SIDA (RIS RD12/0017/0005, RD12/0017/0014).To assess in a cohort of Caucasian patients exposed to stavudine (d4T) the association of polymorphisms in pyrimidine pathway enzymes and HLA-B*40∶01 carriage with HIV/Highly active antiretroviral therapy (HAART)-associated lipodystrophy syndrome (HALS). Three-hundred and thirty-six patients, 187 with HALS and 149 without HALS, and 72 uninfected subjects were recruited. The diagnosis of HALS was performed following the criteria of the Lipodystrophy Severity Grading Scale. Polymorphisms in the thymidylate synthase (TS) and methylene-tetrahydrofolate reductase (MTHFR) genes were determined by direct sequencing, HLA-B genotyping by PCR-SSOr Luminex Technology, and intracellular levels of stavudine triphosphate (d4T-TP) by a LC-MS/MS assay method. HALS was associated with the presence of a low expression TS genotype polymorphism (64.7% vs. 42.9%, OR = 2.43; 95%CI: 1.53-3.88, P<0.0001). MTHFR gene polymorphisms and HLA-B*40∶01 carriage were not associated with HALS or d4T-TP intracellular levels. Low and high expression TS polymorphisms had different d4T-TP intracellular levels (25.60 vs. 13.60 fmol/10 6 cells, P<0.0001). Independent factors associated with HALS were(OR [95%CI]: (a) Combined TS and MTHFR genotypes (p = 0.006, reference category (ref.): 'A+A'; OR for 'A+B' vs. ref.: 1.39 [0.69-2.80]; OR for 'B+A' vs. ref.: 2.16 [1.22-3.83]; OR for 'B+B' vs. ref.: 3.13, 95%CI: 1.54-6.35), (b) maximum viral load ≥5 log10 (OR: 2.55, 95%CI: 1.56-4.14, P = 0.001), (c) use of EFV (1.10 [1.00-1.21], P = 0.008, per year of use). HALS is associated with combined low-expression TS and MTHFR associated with high activity polymorphisms but not with HLA-B*40∶01 carriage in Caucasian patients with long-term exposure to stavudine

    Development of novel low-mass module concepts based on MALTA monolithic pixel sensors

    Full text link
    The MALTA CMOS monolithic silicon pixel sensors has been developed in the Tower 180 nm CMOS imaging process. It includes an asynchronous readout scheme and complies with the ATLAS inner tracker requirements for the HL-LHC. Several 4-chip MALTA modules have been built using Al wedge wire bonding to demonstrate the direct transfer of data from chip-to-chip and to read out the data of the entire module via one chip only. Novel technologies such as Anisotropic Conductive Films (ACF) and nanowires have been investigated to build a compact module. A lightweight flex with 17 {\mu}m trace spacing has been designed, allowing compact packaging with a direct attachment of the chip connection pads to the flex using these interconnection technologies. This contribution shows the current state of our work towards a flexible, low material, dense and reliable packaging and modularization of pixel detectors.Comment: 5 pages + 1 page references,8 figure

    Results of a combined monolithic crystal and an array of ASICs controlled SiPMs

    Full text link
    [EN] In this work we present the energy and spatial resolutions we have obtained for a γ ray detector based on a monolithic LYSO crystal coupled to an array of 256 SiPMs. Two crystal configurations of the same trapezoidal shape have been tried. In one approach all surfaces were black painted but the exit one facing the photosensor array which was polished. The other approach included a retroreflector (RR) layer coupled to the entrance face of the crystal powering the amount of transmitted light to the photosensors. Two coupling media between the scintillator and the SiPM array were used, namely direct coupling by means of optical grease and coupling through an array of light guides. Since the same operational voltage was supplied to the entire array, it was needed to equalize their gains before feeding their signals to the Data Acquisition system. Such a job was performed by means of 4 scalable Application Specific Circuits (ASICs). An energy resolution of about 24.4% has been achieved for the direct coupling with the RR layer together with a spatial resolution of approximately 2.9 mm at the detector center. With the light guides coupling the effects of image compression at the edges are significantly minimized, but worsening the energy resolution to about 33.1% with a spatial resolution nearing 4 mm at the detector center. & 2013 Elsevier B.V. All rights reserved.cknowledgments This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (IþDþI) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.; Bellido, P.; Iborra Carreres, A.; Crespo Navarro, E.; Moliner Martínez, L.... (2014). Results of a combined monolithic crystal and an array of ASICs controlled SiPMs. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 734:132-136. https://doi.org/10.1016/j.nima.2013.08.079S13213673

    Depletion depth studies with the MALTA2 sensor, a depleted monolithic active pixel sensor

    Get PDF
    MALTA2 is a depleted monolithic active pixel sensor (DMAPS) developed in the Tower 180 nm CMOS imaging process. Monolithic CMOS sensors offer advantages over current hybrid imaging sensors both in terms of increased tracking performance due to lower material budget but also in terms of ease of integration and construction costs due to the monolithic design. Current research and development efforts are aimed towards radiation-hard designs up to 100 Mrad in Total Ionizing Dose and 3 × 1015 1 MeV neq / cm2 in Non-Ionizing Energy Loss. One important property of a sensor’s radiation hardness is the depletion depth at which efficient charge collection is achieved via drift movement. Grazing angle test-beam data was taken during the 2023 SPS CERN test beam with the MALTA telescope and Edge Transient Current Technique studies were performed at DESY in order to develop a quantitative study of the depletion depth for un-irradiated, epitaxial MALTA2 samples. The study is planned to be extended for irradiated and Czochralski MALTA2 samples

    MALTA monolithic pixel sensors in TowerJazz 180 nm technology

    Get PDF
    Depleted Monolithic Active Pixel Sensors are of highest interest at the HL-LHC and beyond for the replacement of the Pixel trackers in the outermost layers of experiments where the requirement on total area and cost effectiveness is much bigger. They aim to provide high granularity and low material budget over large surfaces with ease of integration. Our research focuses on MALTA, a radiation hard DMAPS with small collection electrode designed in TowerJazz 180 nm CMOS imaging technology and asynchronous read-out. Latest prototypes are radiation hard up to 2 × 1015 1 MeV neq/cm2 with a time resolution better than 2 ns
    corecore