67 research outputs found

    Patient-specific RF safety assessment in MRI: Progress in creating surface-based human head and shoulder models

    No full text
    The interaction of electromagnetic (EM) fields with the human body during magnetic resonance imaging (MRI) is complex and subject specific. MRI radiofrequency (RF) coil performance and safety assessment typically includes numerical EM simulations with a set of human body models. The dimensions of mesh elements used for discretization of the EM simulation domain must be adequate for correct representation of the MRI coil elements, different types of human tissue, and wires and electrodes of additional devices. Examples of such devices include those used during electroencephalography, transcranial magnetic stimulation, and transcranial direct current stimulation, which record complementary information or manipulate brain states during MRI measurement. The electrical contact within and between tissues, as well as between an electrode and the skin, must also be preserved. These requirements can be fulfilled with anatomically correct surface-based human models and EM solvers based on unstructured meshes. Here, we report (i) our workflow used to generate the surface meshes of a head and torso model from the segmented AustinMan dataset, (ii) head and torso model mesh optimization for three-dimensional EM simulation in ANSYS HFSS, and (iii) several case studies of MRI RF coil performance and safety assessment

    Acute Exposure to Terrestrial Trunked Radio (TETRA) has effects on the electroencephalogram and electrocardiogram, consistent with vagal nerve stimulation

    Get PDF
    BACKGROUND: Terrestrial Trunked Radio (TETRA) is a telecommunications system widely used by police and emergency services around the world. The Stewart Report on mobile telephony and health raised questions about possible health effects associated with TETRA signals. This study investigates possible effects of TETRA signals on the electroencephalogram and electrocardiogram in human volunteers. METHODS: Blinded randomized provocation study with a standardized TETRA signal or sham exposure. In the first of two experiments, police officers had a TETRA set placed first against the left temple and then the upper-left quadrant of the chest and the electroencephalogram was recorded during rest and active cognitive processing. In the second experiment, volunteers were subject to chest exposure of TETRA whilst their electroencephalogram and heart rate variability derived from the electrocardiogram were recorded. RESULTS: In the first experiment, we found that exposure to TETRA had consistent neurophysiological effects on the electroencephalogram, but only during chest exposure, in a pattern suggestive of vagal nerve stimulation. In the second experiment, we observed changes in heart rate variability during exposure to TETRA but the electroencephalogram effects were not replicated. CONCLUSIONS: Observed effects of exposure to TETRA signals on the electroencephalogram (first experiment) and electrocardiogram are consistent with vagal nerve stimulation in the chest by TETRA. However given the small effect on heart rate variability and the lack of consistency on the electroencephalogram, it seems unlikely that this will have a significant impact on health. Long-term monitoring of the health of the police force in relation to TETRA use is on-going

    Mobile phone use and risk of acoustic neuroma: results of the Interphone case–control study in five North European countries

    Get PDF
    There is public concern that use of mobile phones could increase the risk of brain tumours. If such an effect exists, acoustic neuroma would be of particular concern because of the proximity of the acoustic nerve to the handset. We conducted, to a shared protocol, six population-based case–control studies in four Nordic countries and the UK to assess the risk of acoustic neuroma in relation to mobile phone use. Data were collected by personal interview from 678 cases of acoustic neuroma and 3553 controls. The risk of acoustic neuroma in relation to regular mobile phone use in the pooled data set was not raised (odds ratio (OR)=0.9, 95% confidence interval (CI): 0.7–1.1). There was no association of risk with duration of use, lifetime cumulative hours of use or number of calls, for phone use overall or for analogue or digital phones separately. Risk of a tumour on the same side of the head as reported phone use was raised for use for 10 years or longer (OR=1.8, 95% CI: 1.1–3.1). The study suggests that there is no substantial risk of acoustic neuroma in the first decade after starting mobile phone use. However, an increase in risk after longer term use or after a longer lag period could not be ruled out

    Mobile Phones and Multiple Sclerosis – A Nationwide Cohort Study in Denmark

    Get PDF
    We investigated the risk of, prognosis of and symptoms of multiple sclerosis (MS) among all Danish residents who owned a mobile phone subscription before 1996. Using the Danish Multiple Sclerosis Registry and Civil Registration System, study subjects were followed up for MS through 2004. Poisson models were used to calculate incidence rate ratios (IRR, age range: 18–64 years) and mortality rate ratios (MRR, age range: 18+) and to compare presenting symptoms among subscribers and all non-subscribers. A total of 405 971 subscription holders accrued four million years of follow up, with men accounting for 86% of the observation time. Among subscription holding men, the IRR of MS was close to unity, overall as well as 13+ years after first subscription (IRR 1.02, 95% CI: 0.48–2.16). Among women, the IRR was 3.43 (95% CI: 0.86–13.72) 13+ years after first subscription, however, based on only two cases. Presenting symptoms of MS differed between subscribers and non-subscribers (p = 0.03), with slightly increased risk of diplopia in both genders (IRR: 1.38, 95% CI: 1.02–1.86), an increased risk of fatigue among women (IRR: 3.02, 95% CI: 1.45–6.28), and of optic neuritis among men (IRR: 1.38, 95% CI: 1.03–1.86). Overall the MRR was close to one (MRR: 0.91, 95%CI 0.70–1.19) among MS-patients with a subscription and although we observed some increased MRR estimates among women, these were based on small numbers. In conclusion, we found little evidence for a pronounced association between mobile phone use and risk of MS or mortality rate among MS patients. Symptoms of MS differed between subscribers and nonsubscribers for symptoms previously suggested to be associated with mobile phone use. This deserves further attention, as does the increased long-term risk of MS among female subscribers, although small numbers and lack of consistency between genders prevent causal interpretation

    Effect Of Cardiac Motion On Body Surface Electrocardiographic Potentials: An MRI-Based Simulation Study

    Get PDF
    This paper describes an electrical model of cardiac ventricles incorporating real geometry and motion. The heart anatomy and its motion through the cardiac cycle are obtained from segmentations of multiple-slice MRI time sequences; the special conduction system is constructed using an automated mapping procedure from an existing static heart model. The heart model is mounted in an anatomically realistic voxel model of the human body. The cardiac electrical source and surface potentials are determined numerically using both a finite-difference scheme and a boundary-element method with the incorporation of the motion of the heart. The electrocardiograms (ECG) and body surface potential maps are calculated and compared to the static simulation in the resting heart. The simulations demonstrate that introducing motion into the cardiac model modifies the ECG signals, with the most obvious change occurring during the T-wave at peak contraction of the ventricles. Body surface potential maps differ in some local positions during the T-wave, which may be of importance to a number of cardiac models, including those incorporating inverse methods

    The calculation of SAR from limb current in the female voxel phantom, NAOMI

    No full text
    • …
    corecore