1,235 research outputs found

    Ni and Ni Silicides Ohmic Contacts on N-type 6H-SiC with Medium and Low Doping Level

    Get PDF
    Ni silicides contacts, which are expected to be advantageous contact materials on SiC, were tested in this work. Prepared contact structures were ohmic with low contact resistivity approximately 8×10-4 Ω cm2 after annealing at 960°C as far as the SiC substrate with a medium doping level was concerned, no matter whether Ni or Ni silicides were used. At lower annealing temperatures, only Schottky behavior was observed by means of I-V characteristics measurements. In the case of SiC substrate with a low doping level, the behavior differed. It was necessary to anneal the structures at 1070°C to see ohmic behavior appearing with resistivities reaching 8×10-3 Ω cm2 and this was valid only for Ni and Ni2Si. Raman spectroscopy measurements confirmed formation of single Ni silicides as expected. It was found that Ni silicides can keep as good resistivity as Ni contacts while they interact with SiC in limited way and their undesirable drop-like morphology is expected to be overcome for example with a covering layer

    Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector

    Full text link
    The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for XENON1T, of which the impact on the detector performance is discussed. All photomultipliers have been tested in a nitrogen atmosphere at cryogenic temperatures, with a subset of the tubes being tested in gaseous and liquid xenon, simulating their operating conditions in the dark matter detector. The performance and evaluation of the tubes in the different environments is reported and the criteria for rejection of PMTs are outlined and quantified.Comment: 24 pages, 16 figure

    Radon daughter removal from PTFE surfaces and its application in liquid xenon detectors

    Get PDF
    Long-lived radon daughters are a critical background source in experiments searching for low-energy rare events. Originating from radon in ambient air, radioactive polonium, bismuth and lead isotopes plate-out on materials that are later employed in the experiment. In this paper, we examine cleaning procedures for their capability to remove radon daughters from PTFE surfaces, a material often used in liquid xenon TPCs. We found a large difference between the removal efficiency obtained for the decay chains of 222^{222}Rn and 220^{220}Rn, respectively. This indicates that the plate-out mechanism has an effect on the cleaning success. While the long-lived 222^{222}Rn daughters could be reduced by a factor of ~2, the removal of 220^{220}Rn daughters was up to 10 times more efficient depending on the treatment. Furthermore, the impact of a nitric acid based PTFE cleaning on the liquid xenon purity is investigated in a small-scale liquid xenon TPC

    Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector

    No full text
    The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for XENON1T, of which the impact on the detector performance is discussed. All photomultipliers have been tested in a nitrogen atmosphere at cryogenic temperatures, with a subset of the tubes being tested in gaseous and liquid xenon, simulating their operating conditions in the dark matter detector. The performance and evaluation of the tubes in the different environments is reported and the criteria for rejection of PMTs are outlined and quantified

    Search for Two-Neutrino Double Electron Capture of 124^{124}Xe with XENON100

    Get PDF
    Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For 124^{124}Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of 124^{124}Xe using 7636 kg\cdotd of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life T1/2>6.5×1020T_{1/2}>6.5\times10^{20} yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and find a sensitivity of T1/2>6.1×1022T_{1/2}>6.1\times10^{22} yr after an exposure of 2 t\cdotyr.Comment: 6 pages, 4 figure

    Removing krypton from xenon by cryogenic distillation to the ppq level

    Get PDF
    The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β\beta-emitter 85^{85}Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentration of natural krypton in xenon nat\rm{^{nat}}Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 1015^{-15} mol/mol) is required. In this work, the design of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4\cdot105^5 with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of nat\rm{^{nat}}Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN

    Associations of modern initial antiretroviral drug regimens with all-cause mortality in adults with HIV in Europe and North America: a cohort study

    Get PDF
    Background: Over the past decade, antiretroviral therapy (ART) regimens that include integrase strand inhibitors (INSTIs) have become the most commonly used for people with HIV starting ART. Although trials and observational studies have compared virological failure on INSTI-based with other regimens, few data are available on mortality in people with HIV treated with INSTIs in routine care. Therefore, we compared all-cause mortality between different INSTI-based and non-INSTI-based regimens in adults with HIV starting ART from 2013 to 2018. Methods: This cohort study used data on people with HIV in Europe and North America from the Antiretroviral Therapy Cohort Collaboration (ART-CC) and UK Collaborative HIV Cohort (UK CHIC). We studied the most common third antiretroviral drugs (additional to nucleoside reverse transcriptase inhibitor) used from 2013 to 2018: rilpivirine, darunavir, raltegravir, elvitegravir, dolutegravir, efavirenz, and others. Adjusted hazard ratios (aHRs; adjusted for clinical and demographic characteristics, comorbid conditions, and other drugs in the regimen) for mortality were estimated using Cox models stratified by ART start year and cohort, with multiple imputation of missing data. Findings: 62 500 ART-naive people with HIV starting ART (12 422 [19·9%] women; median age 38 [IQR 30–48]) were included in the study. 1243 (2·0%) died during 188 952 person-years of follow-up (median 3·0 years [IQR 1·6–4·4]). There was little evidence that mortality rates differed between regimens with dolutegravir, elvitegravir, rilpivirine, darunavir, or efavirenz as the third drug. However, mortality was higher for raltegravir compared with dolutegravir (aHR 1·49, 95% CI 1·15–1·94), elvitegravir (1·86, 1·43–2·42), rilpivirine (1·99, 1·49–2·66), darunavir (1·62, 1·33–1·98), and efavirenz (2·12, 1·60–2·81) regimens. Results were similar for analyses making different assumptions about missing data and consistent across the time periods 2013–15 and 2016–18. Rates of virological suppression were higher for dolutegravir than other third drugs. Interpretation: This large study of patients starting ART since the introduction of INSTIs found little evidence that mortality rates differed between most first-line ART regimens; however, raltegravir-based regimens were associated with higher mortality. Although unmeasured confounding cannot be excluded as an explanation for our findings, virological benefits of first-line INSTIs-based ART might not translate to differences in mortality. Funding: US National Institute on Alcohol Abuse and Alcoholism and UK Medical Research Council
    corecore