53 research outputs found

    The Potentials and Challenges of Achieving Sustainability through Charcoal Producer Associations in Kenya: A Missed Opportunity?

    Get PDF
    Copyright: © 2021 by the authors. The charcoal industry, specifically charcoal production, is tremendously valuable to Kenya for its contribution to economic, social and environmental nexus. Considering the degradation of ecosystems and charcoal production’s critical role, the government established the Forest (charcoal) rules of 2009, assigning commercial charcoal production under Charcoal Producer Associations (CPAs). Identifying numerous bans in the recent past, this paper sets out to understand CPAs’ potentials and challenges in attaining sustainability within the sector. Using focus group discussions with CPA members from Tana River and Kitui counties, the paper outlines analysed data within the functionality, governance and policy implications parameters of operation. The findings show high economic value for the members and an in-depth environmental significance to the communities within which these CPAs exist. Thus, we propose a schematic to enhance charcoal production processes to achieve sustainable ecosystems and livelihoods. There is high potential within the CPAs for the sector’s sustainability through monitoring platforms, restoration plans, adopting sustainable practices, knowledge dissemination and societal advancement. To advance this untapped potential of these associations, we recommend building their technical, business and governance skills, exploring various restoration schemes, financial and regulatory support in implementation, and policy support.Forest, Trees and Agroforestry (FTA) Program of the CGIA

    Accessible opera : overcoming linguistic and sensorial barriers

    Get PDF
    The desire to make media available for all has been rapidly accepted and implemented by most European countries. Opera, as one of the many audiovisual representations, also falls under the category of production which needs to be made accessible and this article aims to analyse how opera has gone through a complete transformation to become a cultural event for all, overcoming not only linguistic but also sensorial barriers. The first part of the article analyses the various forms of translation associated with opera and the main challenges they entail. The second presents different systems used to make opera accessible to the sensorially challenged, highlighting their main difficulties. Examples from research carried out at the Barcelona's Liceu opera house are presented to illustrate various modalities, especially audio description. All in all, it is our aim to show how translated-related processes have made it possible to open opera to a wider audience despite some initial reluctance

    Thermal denaturation of A-DNA

    Get PDF
    The DNA molecule can take various conformational forms. Investigations focus mainly on the so-called ‘B-form’, schematically drawn in the famous paper by Watson and Crick [1]. This is the usual form of DNA in a biological environment and is the only form that is stable in an aqueous environment. Other forms, however, can teach us much about DNA. They have the same nucleotide base pairs for ‘building blocks’ as B-DNA, but with different relative positions, and studying these forms gives insight into the interactions between elements under conditions far from equilibrium in the B-form. Studying the thermal denaturation is particularly interesting because it provides a direct probe of those interactions which control the growth of the fluctuations when the ‘melting’ temperature is approached. Here we report such a study on the ‘A-form’ using calorimetry and neutron scattering. We show that it can be carried further than a similar study on B-DNA, requiring the improvement of thermodynamic models for DNA

    Audio Description Washes Brighter? A Study in Brand Names and Advertising

    Get PDF
    Dealing with objects in audio description, and particularly with those objects that have a clear designer imprint or branding, is a complex matter when a brand name is part of the scene in a film. Deciding whether to describe or not, and how, becomes more than a technical matter that depends on text–image synchronization: it is a complex decision-making process comparable to other forms of audiovisual translation that needs to be approached as a paradigmatic example of intersemiotic translation. Dávila-Montes and Orero address the audio description of branded objects in movies, and their intersemiotic translation from images to spoken words, a complex issue that may harbour additional insights into topics of a wider scope

    Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    Full text link
    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant. No. FIS2010-21216-CO2-01TEO 2008/114.Moliner Martínez, L.; Correcher, C.; González Martínez, AJ.; Conde Castellanos, PE.; Hernández Hernández, L.; Orero Palomares, A.; Rodríguez Álvarez, MJ.... (2013). Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:129-132. https://doi.org/10.1016/j.nima.2012.08.029S12913270

    Monolithic crystals for PET devices: optical coupling optimization

    Full text link
    NOTICE: this is the author’s version of a work that was accepted for publication in Nuclear Instruments and Methods in Physics Research Section A. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A [Volume 731, 11 December 2013, Pages 288–294] DOI 10.1016/j.nima.2013.05.049[EN] In this work we present a method to efficiently collect scintillation light when using monolithic scintillator crystals. The acceptance angle of the scintillation light has been reduced by means of optical devices reducing the border effect which typically affects continuous crystals. We have applied this procedure on gamma detectors for PET systems using both position sensitive PMTs and arrays of SiPMs. In the case of using SiPMs, this approach also helps to reduce the photosensor active area. We evaluated the method using PMTs with a variety of different crystals with thicknesses ranging from 10 to 24 mm. We found that our design allows the use of crystal blocks with a thickness of up to 18 mm without degrading the spatial resolution caused by edge effects and without a significant detriment to the energy resolution. These results were compared with simulated data. The first results of monolithic LYSO crystals coupled to an array of 256 SiPMs by means of individual optical light guides are also presented.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D +I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.González Martínez, AJ.; Peiró, A.; Conde, P.; Hernández Hernández, L.; Moliner Martínez, L.; Orero Palomares, A.; Rodríguez-Álvarez, M.... (2013). Monolithic crystals for PET devices: optical coupling optimization. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 731:288-294. https://doi.org/10.1016/j.nima.2013.05.049S28829473

    Activation of Serine One-Carbon Metabolism by Calcineurin A beta 1 Reduces Myocardial Hypertrophy and Improves Ventricular Function

    Get PDF
    Background In response to pressure overload, the heart develops ventricular hypertrophy that progressively decompensates and leads to heart failure. This pathological hypertrophy is mediated, among others, by the phosphatase calcineurin and is characterized by metabolic changes that impair energy production by mitochondria. Objectives The authors aimed to determine the role of the calcineurin splicing variant CnAβ1 in the context of cardiac hypertrophy and its mechanism of action. Methods Transgenic mice overexpressing CnAβ1 specifically in cardiomyocytes and mice lacking the unique C-terminal domain in CnAβ1 (CnAβ1Δi12 mice) were used. Pressure overload hypertrophy was induced by transaortic constriction. Cardiac function was measured by echocardiography. Mice were characterized using various molecular analyses. Results In contrast to other calcineurin isoforms, the authors show here that cardiac-specific overexpression of CnAβ1 in transgenic mice reduces cardiac hypertrophy and improves cardiac function. This effect is mediated by activation of serine and one-carbon metabolism, and the production of antioxidant mediators that prevent mitochondrial protein oxidation and preserve ATP production. The induction of enzymes involved in this metabolic pathway by CnAβ1 is dependent on mTOR activity. Inhibition of serine and one-carbon metabolism blocks the beneficial effects of CnAβ1. CnAβ1Δi12 mice show increased cardiac hypertrophy and declined contractility. Conclusions The metabolic reprogramming induced by CnAβ1 redefines the role of calcineurin in the heart and shows for the first time that activation of the serine and one-carbon pathway has beneficial effects on cardiac hypertrophy and function, paving the way for new therapeutic approaches

    Design of the PET–MR system for head imaging of the DREAM Project

    Full text link
    NOTICE: this is the author’s version of a work that was accepted for publication in Nuclear Instruments and Methods in Physics Research Section A. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A, Volume 702, 21 February 2013, Pages 94–97 DOI 10.1016/j.nima.2012.08.028In this paper we describe the overall design of a PET–MR system for head imaging within the framework of the DREAM Project as well as the first detector module tests. The PET system design consists of 4 rings of 16 detector modules each and it is expected to be integrated in a head dedicated radio frequency coil of an MR scanner. The PET modules are based on monolithic LYSO crystals coupled by means of optical devices to an array of 256 Silicon Photomultipliers. These types of crystals allow to preserve the scintillation light distribution and, thus, to recover the exact photon impact position with the proper characterization of such a distribution. Every module contains 4 Application Specific Integrated Circuits (ASICs) which return detailed information of several light statistical momenta. The preliminary tests carried out on this design and controlled by means of ASICs have shown promising results towards the suitability of hybrid PET–MR systems.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I + D + I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.González Martínez, AJ.; Conde, P.; Hernández Hernández, L.; Herrero Bosch, V.; Moliner Martínez, L.; Monzó Ferrer, JM.; Orero Palomares, A.... (2013). Design of the PET–MR system for head imaging of the DREAM Project. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:94-97. https://doi.org/10.1016/j.nima.2012.08.028S949770

    Expectation maximization (EM) algorithms using polar symmetriesfor computed tomography(CT) image reconstruction

    Full text link
    We suggest a symmetric-polar pixellation scheme which makes possible a reduction of the computational cost for expectation maximization (EM) iterative algorithms. The proposed symmetric-polar pixellation allows us to deal with 3D images as a whole problem without dividing the 3D problem into 2D slices approach. Performance evaluation of each approach in terms of stability and image quality is presented. Exhaustive comparisons between all approaches were conducted in a 2D based image reconstruction model. From these 2D approaches, that showing the best performances were finally implemented and evaluated in a 3D based image reconstruction model. Comparison to 3D images reconstructed with FBP is also presented. Although the algorithm is presented in the context of computed tomography (CT) image reconstruction, it can be applied to any other tomographic technique as well, due to the fact that the only requirement is a scanning geometry involving measurements of an object under different projection angles. Real data have been acquired with a small animal (CT) scanner to verify the proposed mathematical description of the CT system.This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant, FIS2010-21216-CO2-01, Valencian Local Government under Grant Nos. PROMETEO 2008/114 and APOSTD/2010/012. The authors would like to thank Brennan Holt for checking and correcting the text.Rodríguez Álvarez, MJ.; Soriano Asensi, A.; Iborra Carreres, A.; Sánchez Martínez, F.; González Martínez, AJ.; Conde, P.; Hernández Hernández, L.... (2013). Expectation maximization (EM) algorithms using polar symmetriesfor computed tomography(CT) image reconstruction. Computers in Biology and Medicine. 43(8):1053-1061. https://doi.org/10.1016/j.compbiomed.2013.04.015S1053106143
    corecore