9 research outputs found

    Vasoactive and/or inotropic drugs in initial resuscitation of burn injuries: A systematic review

    Get PDF
    Background According to current guidelines, initial burn resuscitation should be performed with fluids alone. The aims of the study were to review the frequency of use of vasoactive and/or inotropic drugs in initial burn resuscitation, and assess the benefits and harms of adding such drugs to fluids. Methods A systematic literature search was conducted in PubMed, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, UpToDate, and SveMed+ through 3 December 2021. The search included studies on critically ill burn patients receiving vasoactive and/or inotropic drugs in addition to fluids within 48 h after burn injury. Results The literature search identified 1058 unique publications that were screened for inclusion. After assessing 115 publications in full text, only two retrospective cohort studies were included. One study found that 16 out of 52 (31%) patients received vasopressor(s). Factors associated with vasopressor use were increasing age, burn depth, and % total body surface area (TBSA) burnt. Another study observed that 20 out of 111 (18%) patients received vasopressor(s). Vasopressor use was associated with increasing age, Baux score, and %TBSA burnt in addition to more frequent dialysis treatment and increased mortality. Study quality assessed by the Newcastle-Ottawa quality assessment scale was considered good in one study, but uncertain due to limited description of methods in the other. Conclusion This systematic review revealed that there is a lack of evidence regarding the benefits and harms of using vasoactive and/or inotropic drugs in addition to fluids during early resuscitation of patients with major burns.publishedVersio

    Changes in epidemiology and care strategies at the Norwegian National Burn Centre over 35 years (1986–2020)

    Get PDF
    Introduction: We evaluated trends in admissions, % TBSA (total body surface area) burnt, age, and outcomes over a 35-year period at the national burn centre in Norway. Methods: Relevant data were extracted from the departmental quality registry covering all acute admissions for burns during 1986–2020. Results: In 1986–2020 there were 2.889 admissions for burns (67.6 % males), with a 110 % increase in 2016–20 when compared to 1986–90. Admissions of children <2 years increased by 400 %. In 2011–20, 66.5 % of patients were transferred from other hospitals.The median area injured declined markedly, from 16.5% TBSA in 1986–90 to 4.5% TBSA in 2016–20.Changes in care included an increased focus on non-delayed referrals and transfers, an explicit intent to achieve early excision within 48 h, and a transition from a highly frequent to a less frequent dressing changes scheme.Mortality declined from 10.9 % to 3.0 %. In 2011–20 the mortality among actively treated patients was 2.4 %. For patients with Baux scores 80–119, mortality declined from 36.0 % (1991–2010) to 18.2 % (2011–20) (P < 0.001). Discussion: Since 1986, more patients have been referred to the burn centre, many of younger ages and with more minor burns. Survival of patients with Baux scores 80–119 increased significantly

    Vasoactive and/or inotropic drugs in initial resuscitation of burn injuries: A systematic review

    No full text
    Background According to current guidelines, initial burn resuscitation should be performed with fluids alone. The aims of the study were to review the frequency of use of vasoactive and/or inotropic drugs in initial burn resuscitation, and assess the benefits and harms of adding such drugs to fluids. Methods A systematic literature search was conducted in PubMed, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, UpToDate, and SveMed+ through 3 December 2021. The search included studies on critically ill burn patients receiving vasoactive and/or inotropic drugs in addition to fluids within 48 h after burn injury. Results The literature search identified 1058 unique publications that were screened for inclusion. After assessing 115 publications in full text, only two retrospective cohort studies were included. One study found that 16 out of 52 (31%) patients received vasopressor(s). Factors associated with vasopressor use were increasing age, burn depth, and % total body surface area (TBSA) burnt. Another study observed that 20 out of 111 (18%) patients received vasopressor(s). Vasopressor use was associated with increasing age, Baux score, and %TBSA burnt in addition to more frequent dialysis treatment and increased mortality. Study quality assessed by the Newcastle-Ottawa quality assessment scale was considered good in one study, but uncertain due to limited description of methods in the other. Conclusion This systematic review revealed that there is a lack of evidence regarding the benefits and harms of using vasoactive and/or inotropic drugs in addition to fluids during early resuscitation of patients with major burns

    Mai-Elin Koller

    No full text

    Ventilation practices in burn patients - an international prospective observational cohort study

    No full text
    Background: It is unknown whether lung-protective ventilation is applied in burn patients and whether they benefit from it. This study aimed to determine ventilation practices in burn intensive care units (ICUs) and investigate the association between lung-protective ventilation and the number of ventilator-free days and alive at day 28 (VFD-28). Methods: This is an international prospective observational cohort study including adult burn patients requiring mechanical ventilation. Low tidal volume (V T) was defined as V T ≤ 8 mL/kg predicted body weight (PBW). Levels of positive end-expiratory pressure (PEEP) and maximum airway pressures were collected. The association between V T and VFD-28 was analyzed using a competing risk model. Ventilation settings were presented for all patients, focusing on the first day of ventilation. We also compared ventilation settings between patients with and without inhalation trauma. Results: A total of 160 patients from 28 ICUs in 16 countries were included. Low V T was used in 74% of patients, median V T size was 7.3 [interquartile range (IQR) 6.2-8.3] mL/kg PBW and did not differ between patients with and without inhalation trauma (p = 0.58). Median VFD-28 was 17 (IQR 0-26), without a difference between ventilation with low or high V T (p = 0.98). All patients were ventilated with PEEP levels ≥5 cmH2O; 80% of patients had maximum airway pressures <30 cmH2O. Conclusion: In this international cohort study we found that lung-protective ventilation is used in the majority of burn patients, irrespective of the presence of inhalation trauma. Use of low V T was not associated with a reduction in VFD-28. Trial registration: Clinicaltrials.gov NCT02312869. Date of registration: 9 December 2014

    Ventilation practices in burn patients-an international prospective observational cohort study

    No full text
    Background: It is unknown whether lung-protective ventilation is applied in burn patients and whether they benefit from it. This study aimed to determine ventilation practices in burn intensive care units (ICUs) and investigate the association between lung-protective ventilation and the number of ventilator-free days and alive at day 28 (VFD-28). Methods: This is an international prospective observational cohort study including adult burn patients requiring mechanical ventilation. Low tidal volume (V-T) was defined as V-T &lt;= 8 mL/kg predicted body weight (PBW). Levels of positive end-expiratory pressure (PEEP) and maximum airway pressures were collected. The association between V-T and VFD-28 was analyzed using a competing risk model. Ventilation settings were presented for all patients, focusing on the first day of ventilation. We also compared ventilation settings between patients with and without inhalation trauma. Results: A total of 160 patients from 28 ICUs in 16 countries were included. Low V-T was used in 74% of patients, median V-T size was 7.3 [interquartile range (IQR) 6.2-8.3] mL/kg PBW and did not differ between patients with and without inhalation trauma (p= 0.58). Median VFD-28 was 17 (IQR 0-26), without a difference between ventilation with low or high V-T (p= 0.98). All patients were ventilated with PEEP levels &gt;= 5 cmH(2)O; 80% of patients had maximum airway pressures &lt;30 cmH(2)O. Conclusion: In this international cohort study we found that lung-protective ventilation is used in the majority of burn patients, irrespective of the presence of inhalation trauma. Use of low V-T was not associated with a reduction in VFD-28
    corecore