29 research outputs found

    A New Approach to Background Subtraction in Low-Energy Neutrino Experiments

    Get PDF
    We discuss a new method to extract neutrino signals in low energy experiments. In this scheme the symmetric nature of most backgrounds allows for direct cancellation from data. The application of this technique to the Palo Verde reactor neutrino oscillation experiment allowed us to reduce the measurement errors on the anti-neutrino flux from ∼20\sim 20% to ∼10\sim 10%. We expect this method to substantially improve the data quality in future low background experiments such as KamLAND and LENS.Comment: 7 pages, 2 figure

    Infinitesimal Gribov copies in gauge-fixed topological Yang-Mills theories

    Get PDF
    We study the Gribov problem in four-dimensional topological Yang-Mills theories following the Baulieu-Singer approach in the (anti-)self-dual Landau gauges. This is a gauge-fixed approach that allows to recover the topological spectrum, as first constructed by Witten, by means of an equivariant (or constrained) BRST cohomology. As standard gauge-fixed Yang-Mills theories suffer from the gauge copy (Gribov) ambiguity, one might wonder if and how this has repercussions for this analysis. The resolution of the small (infinitesimal) gauge copies, in general, affects the dynamics of the underlying theory. In particular, treating the Gribov problem for the standard Landau gauge condition in non-topological Yang-Mills theories strongly affects the dynamics of the theory in the infrared. In the current paper, although the theory is investigated with the same gauge condition, the effects of the copies turn out to be completely different. In other words: in both cases, the copies are there, but the effects are very different. As suggested by the tree-level exactness of the topological model in this gauge choice, the Gribov copies are shown to be inoffensive at the quantum level. To be more precise, following Gribov, we discuss the path integral restriction to the Gribov horizon. The associated gap equation, which fixes the so-called Gribov parameter, is however shown to only possess a trivial solution, making the restriction obsolete. We relate this to the absence of radiative corrections in both gauge and ghost sectors. We give further evidence by employing the renormalization group which shows that, for this kind of topological model, the gap equation indeed forbids the introduction of a massive Gribov parameter.Comment: 21 pages. Final version accepted for publication in Physics Letters

    Astronomical Distance Determination in the Space Age: Secondary Distance Indicators

    Get PDF
    The formal division of the distance indicators into primary and secondary leads to difficulties in description of methods which can actually be used in two ways: with, and without the support of the other methods for scaling. Thus instead of concentrating on the scaling requirement we concentrate on all methods of distance determination to extragalactic sources which are designated, at least formally, to use for individual sources. Among those, the Supernovae Ia is clearly the leader due to its enormous success in determination of the expansion rate of the Universe. However, new methods are rapidly developing, and there is also a progress in more traditional methods. We give a general overview of the methods but we mostly concentrate on the most recent developments in each field, and future expectations. © 2018, The Author(s)

    Microfluidic coagulation assay for monitoring anticoagulant therapy in acute stroke patients

    No full text
    Reliable detection of anticoagulation status in patients treated with non-vitamin K antagonist oral anticoagulants (NOACs) is challenging but of importance especially in the emergency setting. This study evaluated the potential of a whole-blood clotting time assay based on Surface Acoustic Waves (SAW-CT) in stroke-patients. The SAW-technology was used for quick and homogenous recalcification of whole blood inducing a surface-activated clotting reaction quantified and visualised by real-time fluorescence microscopy with automatic imaging processing. In 20 stroke or transient ischaemic attack (TIA)-patients taking NOACs kinetics of SAW-CT were assessed and correlated to other coagulation parameters (PT, aPTT) and NOAC-plasma concentration measured by tandem mass spectrometry (LC-MS/MS). In 225 emergency patients with suspicion of acute stroke or TIA, SAW-CT values were assessed. Mean (+/- SD) SAW-CT in non-anticoagulated stroke patients (n=180) was 124 s (+/- 21). In patients on dabigatran or rivaroxaban, SAW-CT values were significantly higher 2 and 8 hours (h) after intake rising up to 267 seconds (s) (dabigatran, 2 h after intake) and 250 s (rivaroxaban, 8 h after intake). In patients on apixaban, SAW-CT values were only moderately increased 2 h after intake (SAW-CT 153 s). In emergency patients, SAW-CT values were significantly higher in NOAC and vitamin K antagonist (VKA)-treated as compared to non-anticoagulated patients. In conclusion, the SAW-CT assay is capable to monitor anticoagulant level and effect in patients receiving dabigatran, rivaroxaban and the VKA phenprocoumon. It has a limited sensitivity for apixaban-detection. If specific SAW-CT results were used as cut-offs, SAW-CT yields high diagnostic accuracy to exclude relevant rivaroxaban and dabigatran concentrations in stroke patients

    Micro-optical prototyping of a surface acoustic wave-based point-of-care coagulation assay and first application in anticoagulated patients

    No full text
    Objective: Clinicians demand for methods to monitor effects of direct anticoagulants in the emergency setting. We recently described a coagulation assay based on surface acoustic waves (SAW) technology, which quantifies anticoagulant effects by image processing. Here we describe the first step in miniaturizing this laboratory method and provide a portable prototype that contains the optical illumination and automatic on-board image processing. Methods: A device about the size of a shoebox was realized that contains the SAW-chip, the signal generator, the LED illumination, as well as the necessary lenses, aperture, and CCD sensor. The microspheres in the blood were mixed by SAW, and the movement of the micro spheres was quantified by on-board image processing. Upon contact with activation induced coagulation, this movement ceases, and coagulation times were measured and compared to the manual methods obtained by standard fluorescent microscopy. A major advantage of our method is the low amount of blood (~ 6 μL) necessary for testing. Results: Results from the prototype correlated accurately with manual methods (Pearson correlation coefficient r = 0.9644). SAW-induced clotting time under anticoagulant treatment with dabigatran or rivaroxaban was well correlated with physicochemically determined plasma concentrations of these DOACs in anticoagulated patients. Compared to manual alignment of the chip under the fluorescence microscope, the prototype had a lower coefficient of variation. Conclusions: The last evolution step towards a point-of-care (POC)-device would be the development of a cartridge (containing calcium chloride and fluorescent label) such that a drop of blood can be introduced into the reaction vessel by a fluid actuator system
    corecore