22 research outputs found

    Comparison of Early and Long-Term Outcomes After Transcatheter Aortic Valve Implantation in Patients with New York Heart Association Functional Class IV to those in Class III and Less

    Get PDF
    Our aim was to investigate the impact of a baseline New York Heart Association (NYHA) class IV on clinical outcomes of a large real-world population who underwent transcatheter aortic valve implantation (TAVI). The primary end points were all-cause mortality, cardiovascular mortality, and re-hospitalization, evaluated at the longest available follow-up and by means of a 3-month landmark analysis. The secondary end points were: change in NYHA class, left ventricular ejection fraction, pulmonary pressure and mitral regurgitation. Out of 2,467 patients, 271 (11%) had a NYHA functional class IV at the admission. The latter had higher Society of Thoracic Surgeons (STS) score (9.2% vs 5.5%; p < 0.001) compared to NYHA ≤ III patients, owing to more comorbidities (prior myocardial infarction, severe long-term kidney disease, atrial fibrillation, left ventricular dysfunction, significant mitral regurgitation, pulmonary hypertension). Device success was similar between the two groups (93.7% vs 94.5%; p = 0.583). At a median follow-up of 15 months (interquartile range 4 to 36 months) a lower freedom from primary end points was observed among NYHA IV versus NYHA ≤ III group (survival from all-cause death: 52% vs 58.4%; p = 0.002; survival from cardiovascular death: 72.5% vs 76.5%; p = 0.091; freedom from re-hospitalization: 81.5% vs 85.4%; p = 0.038). However, after adjustment for baseline imbalance, NYHA IV did not influence the relative risk of long-term primary end points. A 3-month landmark analysis showed that NYHA IV independently predicted 3-month all-cause and cardiovascular mortality (hazard ratio: 1.77; 95% CI [1.10 to 2.83]; p = 0.018 and hazard ratio: 1.64; 95% CI [1.03 to 2.59]; p = 0.036, respectively). Instead, after 3-month follow-up NYHA IV did not affect the risk of primary end points. A significant improvement of the secondary end points was noted in both NYHA IV and NYHA ≤≤ III groups. In conclusion, the presence of NYHA class IV in TAVI candidates was associated to a significant increased risk of mortality within 3 months. Patients with baseline NYHA IV who survived at 3 months had a long-term outcome comparable to that of other subjects. Left ventricular systolic function, pulmonary pressure, and mitral insufficiency significantly improved after TAVI regardless of baseline NYHA class IV

    An unusual case of ST-segment elevation myocardial infarction following a late bare-metal stent fracture in a native coronary artery: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>A bare-metal stent fracture as a cause of acute coronary thrombosis and consequently of acute coronary syndrome is a rare clinical event that, to the best of our knowledge, has previously not been reported. A stent fracture is a rare complication arising from percutaneous coronary intervention.</p> <p>Case presentation</p> <p>We present, to the best of our knowledge, the first documented case of ST-segment elevation myocardial infarction in a patient following a late bare-metal stent fracture and thrombosis in a native coronary artery. The patient, a 51-year-old Caucasian man, was treated successfully with primary percutaneous coronary intervention and a new stent implantation.</p> <p>Conclusion</p> <p>A coronary stent fracture is a rare complication that has been described in venous bypass grafts deploying either a drug-eluting stent or a bare-metal stent. Stent fractures rarely occur in coronary arteries. In light of the non-specific presentation of stent fracture, it is also an easily missed complication. Patients may present with a non-specific symptom of angina. The angina could either be stable or unstable as a result of restenosis or in-stent thrombosis, or both. Our case demonstrates the most severe consequences of a bare-metal stent fracture (sudden coronary thrombosis and subsequent myocardial infarction) in a native coronary artery. It was diagnosed angiographically and treated early and effectively.</p

    Introducing EDEN ISS - A European project on advancing plant cultivation technologies and operations

    Get PDF
    Plant cultivation in large-scale closed environments is challenging and several key technologies necessary for space-based plant production are not yet space-qualified or remain in early stages of development. The EDEN ISS project foresees development and demonstration of higher plant cultivation technologies, suitable for future deployment on the International Space Station and from a long-term perspective, within Moon and Mars habitats. The EDEN ISS consortium will design and test essential plant cultivation technologies using an International Standard Payload Rack form factor cultivation system for potential testing on-board the International Space Station. Furthermore, a Future Exploration Greenhouse will be designed with respect to future planetary bio-regenerative life support system deployments. The technologies will be tested in a laboratory environment as well as at the highly-isolated German Antarctic Neumayer Station III. A small and mobile container-sized test facility will be built in order to provide realistic mass flow relationships. In addition to technology development and validation, food safety and plant handling procedures will be developed. This paper describes the goals and objectives of EDEN ISS and the different project phases and milestones. Furthermore, the project consortium will be introduced and the role of each partner within the project is explained

    A Qualitative Exploration of the Use of Contraband Cell Phones in Secured Facilities

    Get PDF
    Offenders accepting contraband cell phones in secured facilities violate state corrections law, and the possession of these cell phones is a form of risk taking behavior. When offenders continue this risky behavior, it affects their decision making in other domains where they are challenging authorities; and may impact the length of their incarceration. This qualitative phenomenological study examined the lived experience of ex-offenders who had contraband cell phones in secured correctional facilities in order to better understand their reasons for taking risks with contraband cell phones. The theoretical foundation for this study was Trimpop\u27s risk-homeostasis and risk-motivation theories that suggest an individual\u27s behaviors adapt to negotiate between perceived risk and desired risk in order to achieve satisfaction. The research question explored beliefs and perceptions of ex-offenders who chose to accept the risk of using contraband cell phones during their time in secured facilities. Data were collected anonymously through recorded telephone interviews with 8 male adult ex-offenders and analyzed using thematic content analysis. Findings indicated participants felt empowered by possession of cell phones in prison, and it was an acceptable risk to stay connected to family out of concern for loved ones. The study contributes to social change by providing those justice system administrators, and prison managers responsible for prison cell phone policies with more detailed information about the motivations and perspectives of offenders in respect to using contraband cell phones while imprisoned in secured facilities

    Risk factors associated with adverse fetal outcomes in pregnancies affected by Coronavirus disease 2019 (COVID-19): a secondary analysis of the WAPM study on COVID-19.

    Get PDF
    Objectives To evaluate the strength of association between maternal and pregnancy characteristics and the risk of adverse perinatal outcomes in pregnancies with laboratory confirmed COVID-19. Methods Secondary analysis of a multinational, cohort study on all consecutive pregnant women with laboratory-confirmed COVID-19 from February 1, 2020 to April 30, 2020 from 73 centers from 22 different countries. A confirmed case of COVID-19 was defined as a positive result on real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay of nasal and pharyngeal swab specimens. The primary outcome was a composite adverse fetal outcome, defined as the presence of either abortion (pregnancy loss before 22 weeks of gestations), stillbirth (intrauterine fetal death after 22 weeks of gestation), neonatal death (death of a live-born infant within the first 28 days of life), and perinatal death (either stillbirth or neonatal death). Logistic regression analysis was performed to evaluate parameters independently associated with the primary outcome. Logistic regression was reported as odds ratio (OR) with 95% confidence interval (CI). Results Mean gestational age at diagnosis was 30.6+/-9.5 weeks, with 8.0% of women being diagnosed in the first, 22.2% in the second and 69.8% in the third trimester of pregnancy. There were six miscarriage (2.3%), six intrauterine device (IUD) (2.3) and 5 (2.0%) neonatal deaths, with an overall rate of perinatal death of 4.2% (11/265), thus resulting into 17 cases experiencing and 226 not experiencing composite adverse fetal outcome. Neither stillbirths nor neonatal deaths had congenital anomalies found at antenatal or postnatal evaluation. Furthermore, none of the cases experiencing IUD had signs of impending demise at arterial or venous Doppler. Neonatal deaths were all considered as prematurity-related adverse events. Of the 250 live-born neonates, one (0.4%) was found positive at RT-PCR pharyngeal swabs performed after delivery. The mother was tested positive during the third trimester of pregnancy. The newborn was asymptomatic and had negative RT-PCR test after 14 days of life. At logistic regression analysis, gestational age at diagnosis (OR: 0.85, 95% CI 0.8-0.9 per week increase; pPeer reviewe

    Maintenance of Long-Term Clinical Benefit With Sirolimus-Eluting Stents in Patients With ST-Segment Elevation Myocardial Infarction 3-Year Results of the SESAMI (Sirolimus-Eluting Stent Versus Bare-Metal Stent In Acute Myocardial Infarction) Trial

    Get PDF
    ObjectivesThe aim of this study was to investigate whether the reported favorable 1-year outcome of the sirolimus-eluting stent (SES) versus the bare-metal stent (BMS) in the SESAMI (Sirolimus-Eluting Stent Versus Bare-Metal Stent In Acute Myocardial Infarction) trial, in the setting of ST-segment elevation myocardial infarction (STEMI), is maintained at 3-year follow-up.BackgroundAt present, only long-term registry data, but not randomized trials, on the safety and effectiveness of SES in STEMI patients are available.MethodsOverall, 320 STEMI patients were randomized to receive SES or BMS. The primary end point was the incidence of major adverse cardiovascular events (MACE), at 3-year follow-up. The secondary end points were the rate of target lesion revascularization (TLR) and target vessel revascularization (TVR) and target vessel failure (TVF). The incidence of late events, starting from clopidogrel withdrawal, was also investigated.ResultsThe 3-year incidence of MACE was lower in the SES group compared with the BMS group (12.7% vs. 21%, p = 0.034), as were TLR (7% vs. 13.5%, p = 0.048), TVR (8% vs. 16%, p = 0.027), and TVF (11.5% vs. 20.5%, p = 0.028) rates. The 3-year survival rate free from MACE, TLR, and TVF was significantly higher in the SES group than in the BMS group (87%, 93%, and 89.5% vs. 79%, 86.5%, and 79.5%, respectively, p < 0.05). The lower incidence of adverse events in the SES group was driven by TLR reduction and achieved in the first year of follow-up. The cumulative incidence of death and recurrent myocardial infarction, starting from clopidogrel discontinuation, was comparable in the 2 groups.ConclusionsThe clinical benefits of SES have been shown to be greater than those of BMS at 3-year follow-up

    Radial versus femoral access in patients with acute coronary syndromes withor without ST-segment elevation

    Get PDF
    Aims To assess whether radial compared with femoral access is associated with consistent outcomes in patients with ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation acute coronary syndrome (NSTE-ACS). Methods and results In the Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX (MATRIX) programme patients were randomized to radialor femoral access, stratified by STEMI (2001 radial, 2009 femoral) and NSTE-ACS (2196 radial, 2198 femoral). The 30-day co-primaryoutcomes were major adverse cardiovascular events (MACE), defined as death, myocardial infarction, or stroke, and net adverse clinical events (NACE), defined as MACEor major bleeding In the overall study population, radial access reduced the NACE but not MACE endpoint at the prespecified 0.025 alpha. MACE occurred in 121 (6.1%) STEMI patients with radial access vs. 126 (6.3%) patients with femoral access [rate ratio (RR) = 0.96, 95% CI = 0.75-1.24; P = 0.76] and in 248 (11.3%) NSTE-ACS patients with radial access vs. 303 (13.9%) with femoral access (RR = 0.80, 95% CI = 0.67-0.96; P = 0.016) (Pint = 0.25). NACE occurred in 142 (7.2%) STEMI patients with radial access and in 165 (8.3%) patients with femoral access (RR = 0.86, 95% CI = 0.68-1.08; P = 0.18) and in 268 (12.2%) NSTE-ACS patients with radial access compared with 321 (14.7%) with femoral access (RR = 0.82, 95% CI = 0.69-0.97; P = 0.023) (Pint = 0.76). All-cause mortality and access site-actionable bleeding favoured radial access irrespective of ACS type (Pint = 0.11 and Pint = 0.36, respectively). Conclusion Radial as compared with femoral access provided consistent benefit across the whole spectrum of patients with ACS, without evidence that type of presenting syndrome affected the results of the random access allocation
    corecore