338 research outputs found

    Biomedical Engineering Advancements after Management of Myelomeningocele Study (MOMS): A Narrative Review

    Get PDF
    Spina bifida is a neural tube defect resulting from an incomplete closure of the caudal neuropore. The most debilitating form of spina bifida, myelomeningocele (MMC), can present with Chiari II malformation with concomitant hydrocephalus, bowel and bladder abnormalities, and impaired motor function of the lower limbs. The incidence rate of spina bifida is 3.4 per 10,000 live births reported within the US. On average, the US spends $1,176,000,000 annually on patient management and treatment. Advancements in the standard therapy, namely prenatal intervention pioneered by the Management of Myelomeningocele Study (MOMS), have aimed to reduce maternal and fetal complications, and yet complications were increased, calling for the need of further improvements. Beyond current standard interventions for MMC, the most promising developments have employed various biomedical methods ranging from isolated stem cell injections to biodegradable scaffold patches. These scaffolds can be biologic or synthetic and are often incorporated with bioactive proteins or stem cells. This review discusses the benefits and limitations of post-MOMS era biomedical engineering intervention articles found in 3 medical and biomedical databases consisting of systematic reviews, meta-analyses, randomized control trials, and experimental studies. After analysis of the advancements and limitations of these studies, a combination of materials could create a superior scaffold possessing watertight impermeability and cytocompatibility for successful coverage and host integration with minimal inflammation. Coupled with minimally invasive intra-amniotic injection delivery, an earlier mitigation could further prevent progression of poor neurologic outcomes, and possibly even regenerate neuronal tissue in patients with MMC

    100 kV Schottky electron gun

    Get PDF
    We present a comparison between experimental results and computer calculations on a high current, high resolution single lens electrostatic 100 kV Schottky electron gun. One promising application for such an electron gun is for direct electron‐beam patterning of x‐ray masks. The high energy helps provide precise patterning of the thick resist, maintains vertical resist profiles, and minimizes the proximity effect. The gun was designed to operate from 25 to 100 kV, capable of focus at a distance of 145–245 mm with a magnification of 1.15. The emitter, of apex radius ∼0.6 μm operated at 1800 K in the extended Schottky regime, provides an angular intensity of 0.5 mA/sr for an extraction voltage of 5000 V and with a beam limiting aperture of 2.2 mrad, the gun delivers 7 nA of probe current. The gun consists of a replaceable high voltage optic module mounted on a precision insulator with the main acceleration occurring between the exit of the optic module and the grounded anode. A provision is made for alignment of the emitter with respect to the central optical axis of the optic module in a special alignment chamber eliminating the need for high voltage emitter alignment. Final gun alignment is achieved by X–Y motion of the grounded anodeaperture. The gun is constructed to allow ease of replacement of the emitter, the beam defining aperture, and the differential pumping aperture. The beam supply has 10 ppm of ripple while lens supplies have supply, cabling, connectors,insulator, and optic module draw 1 μA of ground leakage current. Pressured SF6 chambers are used for high voltage connector interfaces within the power supply and on the gun

    ‘We need to share our stories’: the lives of Pakistanis with intellectual disability and their guardians

    Get PDF
    Š 2020 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd Introduction: The experiences of Pakistanis with intellectual disabilities (IDs) and their family members have been underexplored empirically. Method: The present study sought to address this gap by understanding the lives of five Special Olympics Pakistan athletes and their guardians through PhotoVoice. Findings: Through thematic analysis, we present the primary theme concerning Pakistan\u27s cultural context that provides an empirical exploration of cultural beliefs about intellectual disability, cultural expectations and support received by people with intellectual disabilities and their guardians. Discussion: We discuss implications for research and practice

    Suppression of Phase Separation in LiFePO4 Nanoparticles During Battery Discharge

    Full text link
    Using a novel electrochemical phase-field model, we question the common belief that LixFePO4 nanoparticles separate into Li-rich and Li-poor phases during battery discharge. For small currents, spinodal decomposition or nucleation leads to moving phase boundaries. Above a critical current density (in the Tafel regime), the spinodal disappears, and particles fill homogeneously, which may explain the superior rate capability and long cycle life of nano-LiFePO4 cathodes.Comment: 27 pages, 8 figure

    Scintillator counters with WLS fiber/MPPC readout for the side muon range detector (SMRD)of the T2K experiment

    Full text link
    The T2K neutrino experiment at J-PARC uses a set of near detectors to measure the properties of an unoscillated neutrino beam and neutrino interaction cross-sections. One of the sub-detectors of the near-detector complex, the side muon range detector (SMRD), is described in the paper. The detector is designed to help measure the neutrino energy spectrum, to identify background and to calibrate the other detectors. The active elements of the SMRD consist of 0.7 cm thick extruded scintillator slabs inserted into air gaps of the UA1 magnet yokes. The readout of each scintillator slab is provided through a single WLS fiber embedded into a serpentine shaped groove. Two Hamamatsu multi-pixel avalanche photodiodes (MPPC's) are coupled to both ends of the WLS fiber. This design allows us to achieve a high MIP detection efficiency of greater than 99%. A light yield of 25-50 p.e./MIP, a time resolution of about 1 ns and a spatial resolution along the slab better than 10 cm were obtained for the SMRD counters.Comment: 7 pages, 4 figures; talk at TIPP09, March 12-17, Tsukuba, Japan; to be published in the conference proceeding

    Intelligent OS X malware threat detection with code inspection

    Get PDF
    With the increasing market share of Mac OS X operating system, there is a corresponding increase in the number of malicious programs (malware) designed to exploit vulnerabilities on Mac OS X platforms. However, existing manual and heuristic OS X malware detection techniques are not capable of coping with such a high rate of malware. While machine learning techniques offer promising results in automated detection of Windows and Android malware, there have been limited efforts in extending them to OS X malware detection. In this paper, we propose a supervised machine learning model. The model applies kernel base Support Vector Machine (SVM) and a novel weighting measure based on application library calls to detect OS X malware. For training and evaluating the model, a dataset with a combination of 152 malware and 450 benign were is created. Using common supervised Machine Learning algorithm on the dataset, we obtain over 91% detection accuracy with 3.9% false alarm rate. We also utilize Synthetic Minority Over-sampling Technique (SMOTE) to create three synthetic datasets with different distributions based on the refined version of collected dataset to investigate impact of different sample sizes on accuracy of malware detection. Using SMOTE datasets we could achieve over 96% detection accuracy and false alarm of less than 4%. All malware classification experiments are tested using cross validation technique. Our results reflect that increasing sample size in synthetic datasets has direct positive effect on detection accuracy while increases false alarm rate in compare to the original dataset

    The T2K Side Muon Range Detector

    Full text link
    The T2K experiment is a long baseline neutrino oscillation experiment aiming to observe the appearance of {\nu} e in a {\nu}{\mu} beam. The {\nu}{\mu} beam is produced at the Japan Proton Accelerator Research Complex (J-PARC), observed with the 295 km distant Super- Kamiokande Detector and monitored by a suite of near detectors at 280m from the proton target. The near detectors include a magnetized off-axis detector (ND280) which measures the un-oscillated neutrino flux and neutrino cross sections. The present paper describes the outermost component of ND280 which is a side muon range detector (SMRD) composed of scintillation counters with embedded wavelength shifting fibers and Multi-Pixel Photon Counter read-out. The components, performance and response of the SMRD are presented.Comment: 13 pages, 19 figures v2: fixed several typos; fixed reference

    Even low level of physical activity is associated with reduced mortality among people with metabolic syndrome, a population based study (the HUNT 2 study, Norway)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Low levels of physical activity may increase the risk of developing metabolic syndrome, a cluster of metabolic factors that are associated with the risk of premature death. It has been suggested that physical activity may reduce the impact of factors associated with metabolic syndrome, but it is not known whether physical activity may reduce mortality in people with metabolic syndrome.</p> <p>Methods</p> <p>In a prospective study of 50,339 people, 13,449 had metabolic syndrome at baseline and were followed up for ten years to assess cause-specific mortality. The population was divided into two age groups: those younger than 65 years of age and those older than age 65. Information on their physical activity levels was collected at baseline.</p> <p>Results</p> <p>Metabolic syndrome was associated with higher mortality from all causes (hazard ratio (HR) 1.35, 95% confidence interval (95% CI) 1.20 to 1.52) and from cardiovascular causes (HR 1.78, 95% CI 1.39 to 2.29) in people younger than 65 years old than among other populations. In older people, there was no overall association of metabolic syndrome with mortality. People with metabolic syndrome who reported high levels of physical activity at baseline were at a reduced risk of death from all causes compared to those who reported no physical activity, both in the younger age group (HR 0.52, 95% CI 0.37 to 0.73) and in the older age group (HR 0.59, 95% CI 0.47 to 0.74).</p> <p>Conclusion</p> <p>Among people with metabolic syndrome, physical activity was associated with reduced mortality from all causes and from cardiovascular causes. Compared to inactivity, even low levels of physical activity were associated with reduced mortality.</p
    • …
    corecore