9 research outputs found

    Validity of ejection fraction as a measure of myocardial functional state: impact of asynchrony

    Get PDF
    Aims The goal of this study was to test whether peculiarities of left ventricular (LV) regional function place limits on the validity of ejection fraction (EF) as a measure of the myocardial functional state. Methods and results Transthoracic and transoesophageal data from patients with a variety of cardiac conditions were used for analysis of LV regional function. The focus was on the effects of mechanical asynchrony. Ejection fraction was calculated on the basis of LV end-diastolic volume and end-systolic volume obtained by two different ways: (i) end-systolic volume as a whole; and (ii) the sum of all regional end-systolic volumes (which may occur at different times). The relative difference, D-EF, between EFs obtained by (i) and (ii) was taken as the ‘merit ’ of EF. A value of zero is the highest merit. Irrespective of the examination method, we found that D-EF was always higher than zero, and that its value depended on the extent of mechanical asynchrony. Conclusions Ejection fraction is not the arithmetic average of regional EFs. An increase of asynchrony increases D-EF, i.e. it reduces the merit of EF as a measure of cardiac function

    Evaluation of tracheal stenosis: comparison between computed tomography virtual tracheobronchoscopy with multiplanar reformatting, flexible tracheofiberoscopy and intra-operative findings

    Get PDF
    The aim of the study was to evaluate and compare various helical CT display modes [virtual endoscopy (VE)] and multiplanar reformations (MPR), conventional flexible tracheobronchoscopy (FT) and intra-operative (IO) findings in patients with tracheal stenosis and to analyze the advantage of MPR and VE in diagnosis and treatment planning and in postoperative follow-up. Thirty-seven patients with tracheal stenosis underwent standard neck and chest CT followed by MPR and VE. Results were correlated with the results of FT and IO findings. Thirty-three of the 37 stenoses were correctly graded and measured adequately using VE. Complete correlation among CT, fiberoptic tracheoscopy, and surgery of stenosis grading, stenosis length and length of planned resection segment of the trachea was noted between 33 of 37 patients with tracheal stenosis. Correlation between VE and IO was noted in 35 of 37 patients and between FT and VE was noted in 33 of 37 patients with tracheal stenosis. The sensitivity of VE was 94–97%, specificity was 100% with comparison to IO findings. The sensitivity and accuracy of MPR was 86–89% and specificity was 100% with comparison to FT findings. The results of the study indicate that VE is an excellent, consistent, and objective technique. VE with MPR is very useful in diagnostic evaluation and treatment planning in patients with tracheal stenosis

    Maximizing Equity in Acute Coronary Syndrome Screening across Sociodemographic Characteristics of Patients

    No full text
    We compared four methods to screen emergency department (ED) patients for an early electrocardiogram (ECG) to diagnose ST-elevation myocardial infarction (STEMI) in a 5-year retrospective cohort through observed practice, objective application of screening protocol criteria, a predictive model, and a model augmenting human practice. We measured screening performance by sensitivity, missed acute coronary syndrome (ACS) and STEMI, and the number of ECGs required. Our cohort of 279,132 ED visits included 1397 patients who had a diagnosis of ACS. We found that screening by observed practice augmented with the model delivered the highest sensitivity for detecting ACS (92.9%, 95%CI: 91.4–94.2%) and showed little variation across sex, race, ethnicity, language, and age, demonstrating equity. Although it missed a few cases of ACS (7.6%) and STEMI (4.4%), it did require ECGs on an additional 11.1% of patients compared to current practice. Screening by protocol performed the worst, underdiagnosing young, Black, Native American, Alaskan or Hawaiian/Pacific Islander, and Hispanic patients. Thus, adding a predictive model to augment human practice improved the detection of ACS and STEMI and did so most equitably across the groups. Hence, combining human and model screening––rather than relying on either alone––may maximize ACS screening performance and equity

    Low-dose CT of the lung: potential value of iterative reconstructions

    No full text
    OBJECTIVES: To prospectively assess the impact of sinogram-affirmed iterative reconstruction (SAFIRE) on image quality of nonenhanced low-dose lung CT as compared to filtered back projection (FBP). METHODS: Nonenhanced low-dose chest CT (tube current-time product: 30 mAs) was performed on 30 patients at 100 kVp and on 30 patients at 80 kVp. Images were reconstructed with FBP and SAFIRE. Two blinded, independent readers measured image noise; two readers assessed image quality of normal anatomic lung structures on a five-point scale. Radiation dose parameters were recorded. RESULTS: Image noise in datasets reconstructed with FBP (57.4 ± 15.9) was significantly higher than with SAFIRE (31.7 ± 9.8, P < 0.001). Image quality was significantly superior with SAFIRE than with FBP (P < 0.01), without significant difference between FBP at 100 kVp and SAFIRE at 80 kVp (P = 0.68). Diagnostic image quality was present with FBP in 96% of images at 100 kVp and 88% at 80 kVp, and with SAFIRE in 100% at 100 kVp and 98% at 80 kVp. There were significantly more datasets with diagnostic image quality with SAFIRE than with FBP (P < 0.01). Mean CTDI(vol) and effective doses were 1.5 ± 0.7 mGy·cm and 0.7 ± 0.2 mSv at 100 kVp, and 1.4 ± 2.8 mGy·cm and 0.5 ± 0.2 mSv at 80 kVp (P < 0.001, both). CONCLUSIONS: Use of SAFIRE in low-dose lung CT reduces noise, improves image quality, and renders more studies diagnostic as compared to FBP. KEY POINTS : • Low-dose computed tomography is an important thoracic investigation tool. • Radiation dose can be less than 1 mSv with iterative reconstructions. • Iterative reconstructions render more low-dose lung CTs diagnostic compared to conventional reconstructions

    The IASLC Lung Cancer Staging Project: Summary of Proposals for Revisions of the Classification of Lung Cancers with Multiple Pulmonary Sites of Involvement in the Forthcoming Eighth Edition of the TNM Classification

    No full text

    The IASLC Lung Cancer Staging Project: Proposals for Coding T Categories for Subsolid Nodules and Assessment of Tumor Size in Part-Solid Tumors in the Forthcoming Eighth Edition of the TNM Classification of Lung Cancer

    No full text

    The IASLC Lung Cancer Staging Project: Background Data and Proposals for the Classification of Lung Cancer with Separate Tumor Nodules in the Forthcoming Eighth Edition of the TNM Classification for Lung Cancer

    No full text

    The IASLC Lung Cancer Staging Project: Background Data and Proposed Criteria to Distinguish Separate Primary Lung Cancers from Metastatic Foci in Patients with Two Lung Tumors in the Forthcoming Eighth Edition of the TNM Classification for Lung Cancer

    No full text
    corecore