56 research outputs found

    Effects of total solar eclipse of 29 March 2006 on surface radiation

    No full text
    International audienceSolar irradiance spectral measurements were performed during a total solar eclipse. The spectral effect of the limb darkening to the global, direct irradiance and actinic flux measurements was investigated. This effect leads to wavelength dependent changes in the measured solar spectra showing a much more pronounced decrease in the radiation at the lower wavelengths. Radiative transfer model results were used for the computation of a correction for the total ozone measurements due to the limb darkening. This correction was found too small to explain the large decrease in total ozone column derived from the standard Brewer measurements, which is an artifact in the measured irradiance due to the increasing contribution of diffuse radiation against the decreasing direct irradiance caused by the eclipse. Calculations of the Extraterrestrial spectrum and the effective sun's temperatures, as measured from ground based direct irradiance measurements, showed an artificial change in the calculations of both quantities due to the fact that radiation coming from the visible part of the sun during the eclipse phases differs from the back body radiation described by the Planck's law

    Nine years of UV aerosol optical depth measurements at Thessaloniki, Greece

    Get PDF
    Spectral measurements of the aerosol optical depth (AOD) and the Ångström coefficient were conducted at Thessaloniki, Greece (40.5° N, 22.9° E) between January 1997 and December 2005 with a Brewer MKIII double-monochromator spectroradiometer. The dataset was compared with collocated measurements of a second spectroradiometer (Brewer MKII) and a CIMEL sun-photometer, showing correlations of 0.93 and 0.98, respectively. A seasonal variation of the AOD was observed at Thessaloniki, with AOD values at 340 nm of 0.52 and 0.28 for August and December respectively. Back trajectories of air masses for up to 4 days were used to assess the influence of long-range transport from various regions to the aerosol load over Thessaloniki. It is shown that part of the observed seasonality can be attributed to air masses with high AOD originating from North-Eastern and Eastern directions during summertime. The analysis of the long-term record (9 years) of AOD showed a downward tendency. A similar decreasing tendency was found in the record of the PM10_{10} aerosol measurements, which are conducted near the surface at 4 air-quality monitoring stations in the area of the city of Thessaloniki

    Evaluation of night-time aerosols measurements and lunar irradiance models in the frame of the first multi-instrument nocturnal intercomparison campaign

    Get PDF
    The first multi-instrument nocturnal aerosol optical depth (AOD) intercom-parison campaign was held at the high-mountain Iza ̃na Observatory (Tener-ife, Spain) in June 2017, involving 2-minutes synchronous measurements fromtwo different types of lunar photometers (Cimel CE318-T and Moon Preci-sion Filter Radiometer, LunarPFR) and one stellar photometer. The Robotic Lunar Observatory (ROLO) model developed by the U.S. Geological Survey(USGS) was compared with the open-access ROLO Implementation for Moonphotometry Observation (RIMO) model. Results showed rather small differ-ences at Iza ̃na over a 2-month time period covering June and July, 2017(±0.01 in terms of AOD calculated by means of a day/night/day coherencetest analysis and±2 % in terms of lunar irradiance). The RIMO model hasbeen used in this field campaign to retrieve AOD from lunar photometricmeasurements. No evidence of significant differences with the Moon’s phase angle wasfound when comparing raw signals of the six Cimel photometers involved inthis field campaign.The raw signal comparison of the participating lunar photometers (Cimeland LunarPFR) performed at coincident wavelengths showed consistent mea-surements and AOD differences within their combined uncertainties at 870 nmand 675 nm. Slightly larger AOD deviations were observed at 500 nm, point-ing to some unexpected instrumental variations during the measurement pe-riod.Lunar irradiances retrieved using RIMO for phase angles varying between0◦and 75◦(full Moon to near quarter Moon) were compared to the irradi-ance variations retrieved by Cimel and LunarPFR photometers. Our resultsshowed a relative agreement within±3.5 % between the RIMO model andthe photometer-based lunar irradiances.The AOD retrieved by performing a Langley-plot calibration each nightshowed a remarkable agreement (better than 0.01) between the lunar pho-tometers. However, when applying the Lunar-Langley calibration using RIMO,AOD differences of up to 0.015 (0.040 for 500 nm) were found, with differ-ences increasing with the Moon’s phase angle. These differences are thoughtto be partly due to the uncertainties in the irradiance models, as well asinstrumental deficiencies yet to be fully understood.High AOD variability in stellar measurements was detected during thecampaign. Nevertheless, the observed AOD differences in the Cimel/stellarcomparison were within the expected combined uncertainties of these twophotometric techniques. Our results indicate that lunar photometry is amore reliable technique, especially for low aerosol loading conditions.The uncertainty analysis performed in this paper shows that the com-bined standard AOD uncertainty in lunar photometry is dependent on thecalibration technique (up to 0.014 for Langley-plot with illumination-basedcorrection, 0.012-0.022 for Lunar-Langley calibration, and up to 0.1 for the 2 Sun-Moon Gain Factor method). This analysis also corroborates that theuncertainty of the lunar irradiance model used for AOD calculation is withinthe 5-10 % expected range.This campaign has allowed us to quantify the important technical diffi-culties that still exist when routinely monitoring aerosol optical propertiesat night-time. The small AOD differences observed between the three typesof photometers involved in the campaign are only detectable under pristinesky conditions such as those found in this field campaign. Longer campaignsare necessary to understand the observed discrepancies between instrumentsas well as to provide more conclusive results about the uncertainty involvedin the lunar irradiance model

    Results from the Fourth WMO Filter Radiometer Comparison for aerosol optical depth measurements

    Get PDF
    This study presents the results of the Fourth Filter Radiometer Comparison that was held in Davos, Switzerland, between 28 September and 16 October 2015. Thirty filter radiometers and spectroradiometers from 12 countries participated including reference instruments from global aerosol networks. The absolute differences of all instruments compared to the reference have been based on the World Meteorological Organization (WMO) criterion defined as follows: 95% of the measured data has to be within 0.005±0.001∕m (where m is the air mass). At least 24 out of 29 instruments achieved this goal at both 500 and 865nm, while 12 out of 17 and 13 out of 21 achieved this at 368 and 412nm, respectively. While searching for sources of differences among different instruments, it was found that all individual differences linked to Rayleigh, NO2, ozone, water vapor calculations and related optical depths and air mass calculations were smaller than 0.01 in aerosol optical depth (AOD) at 500 and 865nm. Different cloud-detecting algorithms used have been compared. Ångström exponent calculations showed relatively large differences among different instruments, partly because of the high calculation uncertainty of this parameter in low AOD conditions. The overall low deviations of these AOD results and the high accuracy of reference aerosol network instruments demonstrated a promising framework to achieve homogeneity, compatibility and harmonization among the different spectral AOD networks in the near future

    Assessment of Sun photometer Langley calibration at the high-elevation sites Mauna Loa and Izaña

    Get PDF
    The aim of this paper is to analyze the suitability of the high-mountain stations Mauna Loa and Izaña for Langley plot calibration of Sun photometers. Thus the aerosol optical depth (AOD) characteristics and seasonality, as well as the cloudiness, have been investigated in order to provide a robust estimation of the calibration uncertainty as well as the number of days that are suitable for Langley calibrations. The data used for the investigations belong to the AERONET and GAW-PFR networks, which maintain reference Sun photometers at these stations with long measurement records: 22 years at Mauna Loa and 15 years at Izaña. In terms of clear-sky and stable aerosol conditions, Mauna Loa (3397&thinsp;m&thinsp;a.s.l.) exhibits on average 377 Langley plots (243 morning and 134 afternoon) per year suitable for Langley plot calibration, whereas Izaña (2373&thinsp;m&thinsp;a.s.l.) shows 343 Langley plots (187 morning and 155 afternoon) per year. The background AOD (500&thinsp;nm) values, on days that are favorable for Langley calibrations, are in the range 0.01–0.02 throughout the year, with well-defined seasonality that exhibits a spring maximum at both stations plus a slight summer increase at Izaña. The statistical analysis of the long-term determination of extraterrestrial signals yields to a calibration uncertainty of  ∼ &thinsp;0.25–0.5&thinsp;%, this uncertainty being smaller in the visible and near-infrared wavelengths and larger in the ultraviolet wavelengths. This is due to atmospheric variability produced by changes in several factors, mainly the AOD. The uncertainty cannot be reduced based only on quality criteria of individual Langley plots and averaging over several days is shown to reduce the uncertainty to the needed levels for reference Sun photometers.</p

    The World Optical Depth Research and Calibration Center (WORCC) quality assurance and quality control of GAW-PFR AOD measurements

    No full text
    The World Optical Depth Research Calibration Center (WORCC) is a section within the World Radiation Center at Physikalisches-Meteorologisches Observatorium (PMOD/WRC), Davos, Switzerland, established after the recommendations of the World Meteorological Organization for calibration of aerosol optical depth (AOD)-related Sun photometers. WORCC is mandated to develop new methods for instrument calibration, to initiate homogenization activities among different AOD networks and to run a network (GAW-PFR) of Sun photometers. In this work we describe the calibration hierarchy and methods used under WORCC and the basic procedures, tests and processing techniques in order to ensure the quality assurance and quality control of the AOD-retrieved data

    Factors affecting solar ultraviolet irradiance measured since 1990 at thessaloniki, greece

    No full text
    Factors affecting the solar spectral ultraviolet (UV) irradiance at Thessaloniki, Greece were investigated using measurements with single- and double-monochromator Brewer spectroradiometer, which started operating respectively in 1989 and 1993 and continue up to the present. The two data records were quality controlled, homogenized and finally merged into one dataset, which was used in the analysis. Subsets of these data corresponding to different solar zenith angles (SZAs) and to cloud-free skies were used to quantify the long-term changes in surface UV irradiance at different wavelengths, and the importance of the factors responsible for these changes is discussed. It is shown that the calculated UV changes vary with SZA due to the different atmospheric path of the photons and the dependence of the diffuse to direct irradiance ratio on the SZA. The effect of total ozone and aerosols on UV irradiance is examined and the corresponding radiation amplification factors (RAFs) at the various wavelengths are calculated. The observed changes in UV irradiance due to ozone are smaller than those expected for the changes in total ozone, suggesting that the influence of the ozone is masked by other factors. An important finding of this study is that the improvement in air quality at Thessaloniki, during the period under examination, is the main reason for the observed increase in solar UV irradiance. © 2009 Taylor &amp; Francis Group, LLC
    corecore