460 research outputs found

    Derivation of a Non-Local Interfacial Hamiltonian for Short-Ranged Wetting II: General Diagrammatic Structure

    Full text link
    In our first paper, we showed how a non-local effective Hamiltionian for short-ranged wetting may be derived from an underlying Landau-Ginzburg-Wilson model. Here, we combine the Green's function method with standard perturbation theory to determine the general diagrammatic form of the binding potential functional beyond the double-parabola approximation for the Landau-Ginzburg-Wilson bulk potential. The main influence of cubic and quartic interactions is simply to alter the coefficients of the double parabola-like zig-zag diagrams and also to introduce curvature and tube-interaction corrections (also represented diagrammatically), which are of minor importance. Non-locality generates effective long-ranged many-body interfacial interactions due to the reflection of tube-like fluctuations from the wall. Alternative wall boundary conditions (with a surface field and enhancement) and the diagrammatic description of tricritical wetting are also discussed.Comment: (14 pages, 2 figures) Submitted J. Phys. Condens. Matte

    Corticosteroid injection for tennis elbow or lateral epicondylitis: a review of the literature

    Get PDF
    Lateral epicondylitis or tennis elbow is a painful and functionally limiting entity affecting the upperextremity and is frequently treated by hand surgeons. Corticosteroid injection is one of the most common interventions for lateral epicondylitis or tennis elbow. Here, a review of the medical literature on this treatment is presented

    Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

    Get PDF
    The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysic

    Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

    Get PDF
    We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent 1/f1/f stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.Comment: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010

    Hábito alimentar de hemípteros fitófagos associados ao cajueiro no Brasil: Aleyrodidae e Coreidae.

    Get PDF
    bitstream/item/211058/1/AAC19005.pd

    Changes in Cardiovascular Disease Risk Factors With Immediate Versus Deferred Antiretroviral Therapy Initiation Among HIV-Positive Participants in the START (Strategic Timing of Antiretroviral Treatment) Trial

    Get PDF
    Introduction-HIV infection and certain antiretroviral therapy (ART) medications increase atherosclerotic cardiovascular disease risk, mediated, in part, through traditional cardiovascular disease risk factors. Methods and Results-We studied cardiovascular disease risk factor changes in the START (Strategic Timing of Antiretroviral Treatment) trial, a randomized study of immediate versus deferred ART initiation among HIV-positive persons with CD4+ cell counts >500 cells/mm(3). Mean change from baseline in risk factors and the incidence of comorbid conditions were compared between groups. The characteristics among 4685 HIV-positive START trial participants include a median age of 36 years, a CD4 cell count of 651 cells/mm(3), an HIV viral load of 12 759 copies/mL, a current smoking status of 32%, a median systolic/diastolic blood pressure of 120/76 mm Hg, and median levels of total cholesterol of 168 mg/dL, low-density lipoprotein cholesterol of 102 mg/dL, and high-density lipoprotein cholesterol of 41 mg/dL. Mean follow-up was 3.0 years. The immediate and deferred ART groups spent 94% and 28% of follow-up time taking ART, respectively. Compared with patients in the deferral group, patients in the immediate ART group had increased total cholesterol and low-density lipoprotein cholesterol and higher use of lipid-lowering therapy (1.2%;95% CI, 0.1-2.2). Concurrent increases in high-density lipoprotein cholesterol with immediate ART resulted in a 0.1 lower total cholesterol to high-density lipoprotein cholesterol ratio (95% CI, 0.1-0.2). Immediate ART resulted in 2.3% less BP-lowering therapy use (95% CI, 0.9-3.6), but there were no differences in new-onset hypertension or diabetes mellitus. Conclusions-Among HIV-positive persons with preserved immunity, immediate ART led to increases in total cholesterol and lowdensity lipoprotein cholesterol but also concurrent increases in high-density lipoprotein cholesterol and decreased use of blood pressure medications. These opposing effects suggest that, in the short term, the net effect of early ART on traditional cardiovascular disease risk factors may be clinically insignificant.

    Web-based monitoring tools for Resistive Plate Chambers in the CMS experiment at CERN

    Get PDF
    The Resistive Plate Chambers (RPC) are used in the CMS experiment at the trigger level and also in the standard offline muon reconstruction. In order to guarantee the quality of the data collected and to monitor online the detector performance, a set of tools has been developed in CMS which is heavily used in the RPC system. The Web-based monitoring (WBM) is a set of java servlets that allows users to check the performance of the hardware during data taking, providing distributions and history plots of all the parameters. The functionalities of the RPC WBM monitoring tools are presented along with studies of the detector performance as a function of growing luminosity and environmental conditions that are tracked over time
    • …
    corecore