134 research outputs found

    Preparation of gellan-cholesterol nanohydrogels embedding baicalin and evaluation of their wound healing activity

    Get PDF
    [EN] In the present work, the preparation, characterization and therapeutic potential of baicalin-loaded nanohydrogels are reported. The nanohydrogels were prepared by sonicating (S nanohydrogel) or autoclaving (A nanohydrogel) a dispersion of cholesterol-derivatized gellan in phosphate buffer. The nanohydrogel obtained by autoclave treatment showed the most promising results: smaller particles ( similar to 362 nm vs. similar to 530 nm), higher homogeneity (polydispersity index = similar to 0.24 vs. similar to 0.47), and lower viscosity than those obtained by sonication. In vitro studies demonstrated the ability of the nanohydrogels to favour the deposition of baicalin in the epidermis. A high biocompatibility was found for baicalin-loaded nanohydrogels, along with a great ability to counteract the toxic effect induced by hydrogen peroxide in cells, as the nanohydrogels re-established the normal conditions (similar to 100% viability). Further, the potential of baicalin-loaded nanohydrogels in skin wound healing was demonstrated in vivo in mice by complete skin restoration and inhibition of specific inflammatory markers (i.e., myeloperoxidase, tumor necrosis factor-alpha, and oedema.Financial support from University "Sapienza" - Progetti di Ricerca: grant RP116154C2EF9AC8 and grant RM11715C1743EE89 are acknowledged.Manconi, M.; Manca, M.; Caddeo, C.; Cencetti, C.; Di Meo, C.; Zoratto, N.; Nácher Alonso, A.... (2018). Preparation of gellan-cholesterol nanohydrogels embedding baicalin and evaluation of their wound healing activity. European Journal of Pharmaceutics and Biopharmaceutics. 127:244-249. https://doi.org/10.1016/j.ejpb.2018.02.015S24424912

    Tentativas de suicidio en el municipio de Valencia.

    Get PDF
    Se obtuvo información sobre las tentativas de suicidio registradas en los libros de urgencias de los hospitales de Valencia ejecutados por residentes de este municipio mayores de 14 años, desde 1982 a 1985. Su análisis mostró que las tasas, la edad, el sexo y el método empleado fueron similares a lo descrito en otros países europeos. Sin embargo, la proporción de personas remitidas a su casa sin mediar ingreso fue comparativamente muy elevad

    Tentativas de suicidio en el municipio de Valencia.

    Get PDF
    Se obtuvo información sobre las tentativas de suicidio registradas en los libros de urgencias de los hospitales de Valencia ejecutados por residentes de este municipio mayores de 14 años, desde 1982 a 1985. Su análisis mostró que las tasas, la edad, el sexo y el método empleado fueron similares a lo descrito en otros países europeos. Sin embargo, la proporción de personas remitidas a su casa sin mediar ingreso fue comparativamente muy elevad

    Deformation of the N=Z nucleus 76Sr using beta-decay studies

    Get PDF
    A novel method of deducing the deformation of the N=Z nucleus 76Sr is presented. It is based on the comparison of the experimental Gamow-Teller strength distribution B(GT) from its beta decay with the results of QRPA calculations. This method confirms previous indications of the strong prolate deformation of this nucleus in a totally independent way. The measurement has been carried out with a large Total Absorption gamma Spectrometer, "Lucrecia", newly installed at CERN-ISOLDE.Comment: Accepted in Phys. Rev. Letter

    ATLAS silicon module assembly and qualification tests at IFIC Valencia

    Full text link
    ATLAS experiment, designed to probe the interactions of particles emerging out of proton proton collisions at energies of up to 14 TeV, will assume operation at the Large Hadron Collider (LHC) at CERN in 2007. This paper discusses the assembly and the quality control tests of forward detector modules for the ATLAS silicon microstrip detector assembled at the Instituto de Fisica Corpuscular (IFIC) in Valencia. The construction and testing procedures are outlined and the laboratory equipment is briefly described. Emphasis is given on the module quality achieved in terms of mechanical and electrical stability.Comment: 23 pages, 38 EPS figures, uses JINST LaTeX clas

    The Neurogenesis Actuator and NR2B/NMDA Receptor Antagonist Ro25-6981 Consistently Improves Spatial Memory Retraining Via Brain Region-Specific Gene Expression

    Get PDF
    NR2B-containing NMDA (NR2B/NMDA) receptors are important in controlling neurogenesis and are involved in generating spatial memory. Ro25-6981 is a selective antagonist at these receptors and actuates neurogenesis and spatial memory. Inter-structural neuroanatomical profiles of gene expression regulating adult neurogenesis and neuroapoptosis require examination in the context of memory retrieval and reversal learning. The aim was to investigate spatial memory retrieval and reversal learning in relation to gene expression-linked neurogenetic processes following blockade of NR2B/NMDA receptors by Ro25-6981. Rats were trained in Morris water maze (MWM) platform location for 5 days. Ro25-6981 was administered (protocol days 6–7) followed by retraining (days 15–18 or 29–32). Platform location was tested (on days 19 or 33) then post-mortem brain tissue sampling (on days 20 or 34). The expression of three genes known to regulate cell proliferation (S100a6), differentiation (Ascl1), and apoptosis (Casp-3) were concomitantly evaluated in the hippocampus, prefrontal cortex, and cerebellum in relation to the MWM performance protocol. Following initial training, Ro25-6981 enhanced visuospatial memory retrieval performance during further retraining (protocol days 29–32) but did not influence visuospatial reversal learning (day 33). Hippocampal Ascl1 and Casp-3 expressions were correspondingly increased and decreased while cerebellar S100a6 and Casp-3 activities were decreased and increased respectively 27 days after Ro25-6981 treatment. Chronological analysis indicated a possible involvement of new mature neurons in the reconfiguration of memory processes. This was attended by behavioral/gene correlations which revealed direct links between spatial memory retrieval enhancement and modified gene activity induced by NR2B/NMDA receptor blockade and upregulation

    Forward SCT Module Assembly and Quality Control at IFIC Valencia

    Get PDF
    This note discusses the assembly and the quality control tests of 282 forward detector modules for the ATLAS Semiconductor Tracker assembled at the Instituto de Fisica Corpuscular (IFIC) in Valencia. The construction and testing procedures are outlined and the laboratory equipment is briefly described. Emphasis is given on the module quality achieved in terms of mechanical and electrical stability

    Proton radiographs using position-sensitive silicon detectors and high-resolution scintillators

    Full text link
    Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and γ\gamma-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a higher conformity in the treatments. Therefore, it causes less damage to the surrounding healthy tissue and less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton Computed Tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Here, results obtained from an experiment performed using a 100-MeV proton beam at the CCB facility in Krakow (Poland) are presented. Proton radiographs of PMMA samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution and sensitivity to different materials. They demonstrate the capabilities of the system to produce images with protons. Structures of up to 2 mm are nicely resolved and the sensitivity of the system was enough to distinguish thicknesses of 10 mm of aluminum or PMMA. This constitutes a first step to validate the device as a proton radiography scanner previous to the future tests as a proton CT scanner.Comment: 7 pages, 11 figures, submitted to IEEE TNS ANIMMA 2021 Conference Proceeding

    Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators

    Get PDF
    7 pags., 11 figs., 1 tab.Proton therapy is a cancer treatment technique currently in growth since it offers advantages with respect to conventional X-ray and ¿ -ray radiotherapy. In particular, better control of the dose deposition allowing to reach higher conformity in the treatments causing less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton computed tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Our prototype is formed by double-sided silicon strip detectors and scintillators of LaBr3(Ce) with high energy resolution and fast response. Here, the results obtained from an experiment performed using a 100-MeV proton beam are presented. Proton radiographs of polymethyl methacrylate (PMMA) samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution, and sensitivity to different materials. Structures of up to 2 mm are well resolved and the sensitivity of the system was enough to distinguish the thicknesses of 10 mm of aluminum or PMMA. The spatial resolution of the images was 0.3 line pairs per mm (MTF-10%). This constitutes the first step to validate the device as a proton radiography scanner.This work has been supported by the PRONTO-CM B2017/BMD-3888 project funded by Comunidad de Madrid (Spain). The research leading to these results has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement no. 654002 (ENSAR2) and grant agreement No [730983] (INSPIRE). This work has been partly supported by the Spanish Funding Agency for Research (AEI) through the PID2019-104390GBI00 and PID2019-104714GB-C21 projects. A.N. Nerio acknowledges the fundings from the Erasmus Mundus Joint Master Degree on Nuclear Physics co-funded by the Erasmus+Programme of the European Union
    corecore