116 research outputs found

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    Assessing the capabilities of direct analysis in real time mass spectrometry for 5-hydroxymethylfurfural quantitation in honey

    No full text
    The limitations of direct analysis in real time mass spectrometry (DART-MS) were shown with the example of 5-hydroxymethylfurfural (HMF) quantitation in honey. An accurate analyte quantitation was impossible because the carbohydrate matrix partially degraded to the analyte in the ionization region. However, at a decreased DART temperature of 150 °C, the DART-MS screening was possible using two spiked reference samples. The influence of instrumental parameters on the composition of the DART mass spectra for HMF and carbohydrates was investigated. Also, first data on scanning surface analysis with DART-MS were obtained giving rise for further studies in this direction. © 2012 Elsevier B.V. All rights reserved

    Coupling of planar chromatography with Direct Analysis in Real Time mass spectrometry

    No full text
    Direct Analysis in Real Time mass spectrometry (DART-MS) is an emerging and rapidly developing area of ambient desorption ionization mass spectrometric techniques. Its coupling with planar chromatography is especially promising, as compared to other ambient desorption ionization techniques, because it does not require the use of liquids that may distort the shape of a spot by diffusion effects. In the first publications on TLC/HPTLC-DART-MS, due to the fixed, horizontally aligned supply of the gas flow from the DART ionization source to the MS inlet, the introduction of HPTLC/TLC plates as cut strips was inconvenient for quantitation, and the repeatability was very low due to the manual positioning. Recently a new version of the DART ion source was suggested, which allows adjusting the angle of the DART gas stream and the use of a motorized rail, thereby, improving highly the capabilities of TLC/HPTLC-DART-MS. This comprehensive review describes the development and analytical capabilities of TLC/HPTLC-DART-MS, and the general DART-MS perspectives for surface analysis or imaging MS. © Versita Sp. z o.o

    Ambient desorption ionization mass spectrometry (DART, DESI) and its bioanalytical applications

    No full text
    In recent years, ambient desorption ionization techniques for mass spectrometry were introduced. Among them, the most established techniques are Direct Analysis in Real Time (DART) and Desorption Electrospray Ionization (DESI). Therefore, the current review focuses on the bioanalytical applications of ambient desorption ionization techniques by the example of DART and DESI mass spectrometry. The potential and also limitations of both ambient mass spectrometry (MS) techniques in such areas, as identification and quantitation of small molecules, coupling DART-MS and DESI-MS with planar chromatography, protein/peptide analysis, as well as molecular imaging applications, are discussed. © 2011 Springer-Verlag

    Determination of drugs and drug-like compounds in different samples with direct analysis in real time mass spectrometry

    No full text
    Direct analysis in real time (DART), a relatively new ionization source for mass spectrometry, ionizes small-molecule components from different kinds of samples without any sample preparation and chromatographic separation. The current paper reviews the published data available on the determination of drugs and drug-like compounds in different matrices with DART-MS, including identification and quantitation issues. Parameters that affect ionization efficiency and mass spectra composition are also discussed. © 2011 Wiley Periodicals, Inc

    Coupling of planar chromatography with Direct Analysis in Real Time mass spectrometry

    No full text
    Direct Analysis in Real Time mass spectrometry (DART-MS) is an emerging and rapidly developing area of ambient desorption ionization mass spectrometric techniques. Its coupling with planar chromatography is especially promising, as compared to other ambient desorption ionization techniques, because it does not require the use of liquids that may distort the shape of a spot by diffusion effects. In the first publications on TLC/HPTLC-DART-MS, due to the fixed, horizontally aligned supply of the gas flow from the DART ionization source to the MS inlet, the introduction of HPTLC/TLC plates as cut strips was inconvenient for quantitation, and the repeatability was very low due to the manual positioning. Recently a new version of the DART ion source was suggested, which allows adjusting the angle of the DART gas stream and the use of a motorized rail, thereby, improving highly the capabilities of TLC/HPTLC-DART-MS. This comprehensive review describes the development and analytical capabilities of TLC/HPTLC-DART-MS, and the general DART-MS perspectives for surface analysis or imaging MS. © Versita Sp. z o.o

    Determination of drugs and drug-like compounds in different samples with direct analysis in real time mass spectrometry

    No full text
    Direct analysis in real time (DART), a relatively new ionization source for mass spectrometry, ionizes small-molecule components from different kinds of samples without any sample preparation and chromatographic separation. The current paper reviews the published data available on the determination of drugs and drug-like compounds in different matrices with DART-MS, including identification and quantitation issues. Parameters that affect ionization efficiency and mass spectra composition are also discussed. © 2011 Wiley Periodicals, Inc
    corecore