590 research outputs found

    The inhibition of Stat5 by a peptide aptamer ligand specific for the DNA binding domain prevents target gene transactivation and the growth of breast and prostate tumor cells

    Get PDF
    The signal transducer and activator of transcription Stat5 is transiently activated by growth factor and cytokine signals in normal cells, but its persistent activation has been observed in a wide range of human tumors. Aberrant Stat5 activity was initially observed in leukemias, but subsequently also found in carcinomas. We investigated the importance of Stat5 in human tumor cell lines. shRNA mediated downregulation of Stat5 revealed the dependence of prostate and breast cancer cells on the expression of this transcription factor. We extended these inhibition studies and derived a peptide aptamer (PA) ligand, which directly interacts with the DNA-binding domain of Stat5 in a yeast-two-hybrid screen. The Stat5 specific PA sequence is embedded in a thioredoxin (hTRX) scaffold protein. The resulting recombinant protein S5-DBD-PA was expressed in bacteria, purified and introduced into tumor cells by protein transduction. Alternatively, S5-DBD-PA was expressed in the tumor cells after infection with a S5-DBD-PA encoding gene transfer vector. Both strategies impaired the DNA-binding ability of Stat5, suppressed Stat5 dependent transactivation and caused its intracellular degradation. Our experiments describe a peptide based inhibitor of Stat5 protein activity which can serve as a lead for the development of a clinically useful compound for cancer treatment

    Touching Space: Distributed Ledger Technology for Tracking and Tracing Certificates

    Get PDF
    Components built into space vehicles and equipment (space products) must meet different regulatory requirements; in detail, each component must be certified and sustainably traceable at all times. Space engineers have expressed the need for an interoperable system to collect, manage and route certifications for components, parts and materials that go into space products. The lack of a unified approach in the European space industry is a challenge for companies involved in product development. This research proposes an open-source, secure, fast and distributed ledger technology (DLT) based solution that fits into any IT environment and is well adapted to the needs of manufacturing companies in the space sector. The results show that a blockchain-based solution based on 'Hyperledger Fabric' combined with the InterPlanetary File System is viable. The results can guide other researchers and practitioners to consider DLTs when changing their certification management paradigm with suppliers, customers and auditors

    Building Digital Trust to Protect Whistleblowers - A blockchain-based Reporting Channel

    Get PDF
    Organizations today need internal reporting channels to report illegal/unethical misconduct. For this purpose, organizations set up one or more - often digital - internal reporting channels. Persons/Employees who want to report misconduct, so-called whistleblowers, expose themselves to reprisals and therefore need trustworthy reporting channels which ensure ´Digital Trust´. Blockchain, a technology that overcomes the need for trust due to its properties of immutability and integrity of data, could be promising as underlying technology for a digital reporting channel which is recognized as trustworthy. In our research, we explored multiple perspectives relevant to a trustworthy digital reporting system. Applying design science research, we evaluated the current state of the art of (digital) reporting channels and developed a prototypical blockchain-based reporting solution called “Integrity@Inside”. The prototype is being iteratively demonstrated and pre-evaluated

    Sonographic visualization and ultrasound-guided blockade of the greater occipital nerve: a comparison of two selective techniques confirmed by anatomical dissection

    Get PDF
    Background Local anaesthetic blocks of the greater occipital nerve (GON) are frequently performed in different types of headache, but no selective approaches exist. Our cadaver study compares the sonographic visibility of the nerve and the accuracy and specificity of ultrasound-guided injections at two different sites. Methods After sonographic measurements in 10 embalmed cadavers, 20 ultrasound-guided injections of the GON were performed with 0.1 ml of dye at the classical site (superior nuchal line) followed by 20 at a newly described site more proximal (C2, superficial to the obliquus capitis inferior muscle). The spread of dye and coloration of nerve were evaluated by dissection. Results The median sonographic diameter of the GON was 4.2×1.4 mm at the classical and 4.0×1.8 mm at the new site. The nerves were found at a median depth of 8 and 17.5 mm, respectively. In 16 of 20 in the classical approach and 20 of 20 in the new approach, the nerve was successfully coloured with the dye. This corresponds to a block success rate of 80% (95% confidence interval: 58-93%) vs 100% (95% confidence interval: 86-100%), which is statistically significant (McNemar's test, P=0.002). Conclusions Our findings confirm that the GON can be visualized using ultrasound both at the level of the superior nuchal line and C2. This newly described approach superficial to the obliquus capitis inferior muscle has a higher success rate and should allow a more precise blockade of the nerv

    Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study

    Get PDF
    Background Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. Methods In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. Results The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Conclusions Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complication

    Ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve: accuracy of a selective new technique confirmed by anatomical dissection

    Get PDF
    Background. Ilioinguinal and iliohypogastric nerve blocks may be used in the diagnosis of chronic groin pain or for analgesia for hernia repair. This study describes a new ultrasound-guided approach to these nerves and determines its accuracy using anatomical dissection control. Methods. After having tested the new method in a pilot cadaver, 10 additional embalmed cadavers were used to perform 37 ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve. After injection of 0.1 ml of dye the cadavers were dissected to evaluate needle position and colouring of the nerves. Results. Thirty-three of the thirty-seven needle tips were located at the exact target point, in or directly at the ilioinguinal or iliohypogastric nerve. In all these cases the targeted nerve was coloured entirely. In two of the remaining four cases parts of the nerves were coloured. This corresponds to a simulated block success rate of 95%. In contrast to the standard ‘blind' techniques of inguinal nerve blocks we visualized and targeted the nerves 5 cm cranial and posterior to the anterior superior iliac spine. The median diameters of the nerves measured by ultrasound were: ilioinguinal 3.0×1.6 mm, and iliohypogastric 2.9×1.6 mm. The median distance of the ilioinguinal nerve to the iliac bone was 6.0 mm and the distance between the two nerves was 10.4 mm. Conclusions. The anatomical dissections confirmed that our new ultrasound-guided approach to the ilioinguinal and iliohypogastric nerve is accurate. Ultrasound could become an attractive alternative to the ‘blind' standard techniques of ilioinguinal and iliohypogastric nerve block in pain medicine and anaesthetic practic

    Ultrasound-guided paravertebral puncture and placement of catheters in human cadavers: an imaging study

    Get PDF
    Background During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. Methods We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. Results The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. Conclusions We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural space

    Ultrasound-guided percutaneous tracheal puncture: a computer-tomographic controlled study in cadavers

    Get PDF
    Background Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasound's usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control. Methods The trachea of nine cadavers was punctured using an in-plane approach with a longitudinal ultrasound visualization of the trachea. As soon as a loss of resistance was felt, or air/fluid could be aspirated into the attached syringe, the syringe was disconnected and the ultrasound transducer set aside. Thereafter, a cricothyroidotomy guidewire was inserted through the needle into the trachea. The needle was then removed, leaving the wire in place and a control CT imaging of the neck and the chest was performed. Primary outcome was successful wire insertion into the trachea. Results Tracheal puncture and wire insertion was successful in eight of nine cadavers at the first attempt and in one at the second attempt (total of 10 puncture attempts, nine successful). In eight of nine successfully inserted wires, the wire was placed on the defined midline. Conclusions Ultrasound guidance can facilitate successful tracheal puncture. However, combining an in-plane approach with a longitudinal ultrasound visualization of the trachea neither guarantees an exact midline puncture nor allows detection of a misplaced guidewir

    Sonoelastography of the Common Flexor Tendon of the Elbow with Histologic Agreement: A Cadaveric Study.

    Get PDF
    Purpose To determine the correlation of the results of conventional B-mode ultrasonography (US) and compression sonoelastography with histologic results in common flexor tendons of the elbow in human cadavers. Materials and Methods Twenty-five common flexor tendons were evaluated in 16 fresh, unembalmed cadavers of 11 women with a median age of 85 years (range, 71-101 years) and five men with a median age of 78 years (range, 70-88 years). Informed consent was provided according to the last will of the donors. B-mode US results were classified as grade 1, normal tendon with homogeneous fibrillar pattern; grade 2, tendon thickening or hypoechoic areas and/or calcifications in less than 30% of the tendon; or grade 3, hypoechoic areas and/or calcifications greater than 30% of the tendon. Sonoelastographic results were grade 1, blue (hardest) to green (hard); grade 2, yellow (soft); and grade 3, red (softest). The intraclass correlation coefficient was calculated to determine agreement with histologic findings for each B-mode US, sonoelastographic, and combined B-mode US and sonoelastographic examination. Histologic results were grade 1, normal, with parallel fibrillar pattern; grade 2, mild tendinopathy, with cellular infiltration, angiogenesis, or fatty vacuoles; or grade 3, severe tendinopathy, with loss of parallel collagen structure and necrosis. Results Histologic alterations were detected in 44% (11 of 25) of biopsy specimens. Intraclass correlation with histologic results was 0.57 for B-mode US, 0.68 for sonoelastography, and 0.84 for the combination of the two approaches. Conclusion The addition of sonoelastography to B-mode US provided statistically significant improvement in correlation with histologic results compared with the use of B-mode US alone (P \u3c .02). (Š) RSNA, 2016 Online supplemental material is available for this article

    The Diverse Roles of γδ T Cells in Cancer: From Rapid Immunity to Aggressive Lymphoma

    Get PDF
    γδ T cells are unique players in shaping immune responses, lying at the intersection between innate and adaptive immunity. Unlike conventional ιβ T cells, γδ T cells largely populate non-lymphoid peripheral tissues, demonstrating tissue specificity, and they respond to ligands in an MHC-independent manner. γδ T cells display rapid activation and effector functions, with a capacity for cytotoxic anti-tumour responses and production of inflammatory cytokines such as IFN-γ or IL-17. Their rapid cytotoxic nature makes them attractive cells for use in anti-cancer immunotherapies. However, upon transformation, γδ T cells can give rise to highly aggressive lymphomas. These rare malignancies often display poor patient survival, and no curative therapies exist. In this review, we discuss the diverse roles of γδ T cells in immune surveillance and response, with a particular focus on cancer immunity. We summarise the intriguing dichotomy between pro- and anti-tumour functions of γδ T cells in solid and haematological cancers, highlighting the key subsets involved. Finally, we discuss potential drivers of γδ T-cell transformation, summarising the main γδ T-cell lymphoma/leukaemia entities, their clinical features, recent advances in mapping their molecular and genomic landscapes, current treatment strategies and potential future targeting options
    • …
    corecore