49 research outputs found

    Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: pilot scan electron microscope and mechanical studies

    Get PDF
    Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bottom at 8 mm depth was reached. OMI designs were analyzed with a scan electron mi - croscope (SEM). Results: SEM images revealed a great variation in product refinement. In the whole sample, a cylindrical OMI shape was associated with higher POS (p<0.001) but lower IT (p=0.002) values. The outer and inner OMI di - ameters were design characteristics well correlated with POS, IT and TF values (ranging from 0.601 to 0.961). Greater thread depth was related to greater POS values (r= 0.628), although OMIs with similar POS values may have different IT values. Thread depth and pitch had some impact on POS. TF depended mainly on the OMI inner (r= 0.961) and outer diameters (r=0.892). A thread depth to outer diameter ratio close to 40% increased TF risk. Conclusions: Although at the same insertion depth the OMI outer and inner diameters are the most important fac - tors for primary stability, other OMI design characteristics (cylindrical vs. conical, thread design) may significantly affect primary stability and torsional fracture. This needs to be considered when selecting the appropriate OMI for the desired orthodontic procedures

    Patient risk factors for developing a drug-related problem in a cardiology ward

    Full text link
    BACKGROUND: Because of the high incidence of drug-related problems (DRPs) among hospitalized patients with cardiovascular diseases and their potential impact on morbidity and mortality, it is important to identify the most susceptible patients, who therefore require closer monitoring of drug therapy. PURPOSE: To identify the profile of patients at higher risk of developing at least one DRP during hospitalization in a cardiology ward. METHOD: We consecutively included all patients hospitalized in the cardiology ward of a teaching hospital in 2009. DRPs were identified through a computerized warning system designed by the pharmacy department and integrated into the electronic medical record. RESULTS: A total of 964 admissions were included, and at least one DRP was detected in 29.8%. The variables associated with a higher risk of these events were polypharmacy (odds ratio [OR]=1.228; 95% confidence interval [CI]=1.153-1.308), female sex (OR=1.496; 95% CI=1.026-2.180), and first admission (OR=1.494; 95% CI=1.005-2.221). CONCLUSION: Monitoring patients through a computerized warning system allowed the detection of at least one DRP in one-third of the patients. Knowledge of the risk factors for developing these problems in patients admitted to hospital for cardiovascular problems helps in identifying the most susceptible patients

    Circulating angiotensin-converting enzyme 2 activity in patients with chronic kidney disease without previous history of cardiovascular disease

    Get PDF
    [Abstract] Background. Patients with cardiovascular (CV) disease have an increased circulating angiotensin-converting enzyme 2 (ACE2) activity, but there is little information about changes in ACE2 in chronic kidney disease (CKD) patients without history of CV disease. We examined circulating ACE2 activity in CKD patients at stages 3–5 (CKD3-5) and in dialysis (CKD5D) without any history of CV disease. Methods. Circulating ACE2 activity was measured in human ethylenediamine-tetraacetic acid (EDTA)-plasma samples from the NEFRONA study (n = 2572): control group (CONT) (n = 568), CKD3-5 (n = 1458) and CKD5D (n = 546). Different clinical and analytical variables such as gender; age; history of diabetes mellitus (DM), dyslipidemia and hypertension; glycaemic, renal, lipid and anaemia profiles; vitamin D analogues treatment and antihypertensive treatments (angiotensin-converting enzyme inhibitor and angiotensin receptor blockade) were analysed. Circulating ACE2 and ACE activities were measured using modified fluorimetric assay for EDTA-plasma samples, where zinc chloride was added to recover enzymatic activity. Results. In CKD3-5 and CKD5D, significant decrease in circulating ACE2 activity was observed when compared with CONT, but no differences were found between CKD3-5 and CKD5 when performing paired case-control studies. By multivariate linear regression analysis, male gender and advanced age were identified as independent predictors of ACE2 activity in all groups. Diabetes was identified as independent predictor of ACE2 activity in CKD3-5. Significant increase in the activity of circulating ACE was found in CKD3-5 and CKD5D when compared with CONT and in CKD5D when compared with CKD3-5. By multiple regression analysis, female gender and younger age were identified as independent predictors of ACE activity in CONT and CKD3-5. Diabetes was also identified as an independent predictor of ACE activity in CKD3-5 patients. Conclusions. Circulating ACE2 and ACE activities can be measured in human EDTA-plasma samples with zinc added to recover enzymatic activity. In a CKD population without previous history of CV disease, ACE2 activity from human EDTA-plasma samples directly correlated with the classical CV risk factors namely older age, diabetes and male gender. Our data suggest that circulating ACE2 is altered in CKD patients at risk for CV event

    Insomnia among patients with advanced disease during admission in a Palliative Care Unit : a prospective observational study on its frequency and association with psychological, physical and environmental factors

    Get PDF
    The aims of this study were: 1) to assess the frequency of insomnia among patients during admission in a Palliative Care Unit (PCU); 2) to study the association between emotional distress and insomnia, taking physical, environmental and other psychological factors into account. Prospective observational study including patients consecutively admitted to a PCU during eight months, excluding those with severe cognitive problems or too low performance status. Insomnia was assessed by asking a single question and by using the Sleep Disturbance Scale (SDS), and emotional distress using the Hospital Anxiety and Depression Scale (HADS). Physical, environmental and other psychological factors potentially interfering with sleep quality were evaluated. Association between insomnia and the factors evaluated was studied using univariate and multivariate regression analyses. 61 patients were included (mean age 71.5 years; 95% with oncological disease); 38 (62%) answered "yes" to the insomnia single question and 29 (47%) showed moderate to severe insomnia according to the SDS. 65% showed clinically significant emotional distress and 79% had nocturnal rumination. The physical symptoms most often mentioned as interfering with sleep quality were pain (69%) and dyspnoea (36%). 77% reported at least one environmental disturbance. In the univariate analysis, answering "yes" to the insomnia single question was significantly associated with higher HADS score, anxiety, nocturnal rumination, clear knowledge of the diagnosis, higher performance status and dyspnoea; moderate to severe insomnia was significantly associated with nocturnal rumination, higher performance status, environmental disturbances and daytime sleepiness. In the multivariate regression analysis, answering "yes" to the single question was associated with dyspnoea (OR 7.2 [1.65-31.27]; p = 0.009), nocturnal rumination (OR 5.5 [1.05-28.49]; p = 0.04) and higher performance status (OR 14.3 [1.62-125.43]; p = 0.017), and moderate to severe insomnia with nocturnal rumination (OR 5.6 [1.1-29.1]; p = 0.041), and inversely associated with daytime sleepiness (OR 0.25 [0.07-0.9]; p = 0.043). Insomnia was highly frequent. Several physical, psychological and environmental factors seemed to influence insomnia. Within the multimodal management of insomnia, the assessment of nocturnal rumination may be of particular interest, irrespective of emotional distress. Further studies with larger sample sizes could confirm this result

    TMAO and Gut Microbial-Derived Metabolites TML and ÎłBB Are Not Associated with Thrombotic Risk in Patients with Venous Thromboembolism

    Get PDF
    Background: The present work evaluates the association between circulating concentrations of Trimethylamine-N-oxide (TMAO), gamma butyrobetaine (ÎłBB), and trimetyllisine (TML) in controls and patients with venous thromboembolism (VTE) with coagulation parameters. Methods: The study involved 54 VTE patients and 57 controls. Platelet function, platelet hyperreactivity, platelet adhesiveness, thrombosis-associated parameters, and thrombin generation parameters were studied. Plasma TMAO, ÎłBB, and TML determination was performed using an ultra-high-performance liquid chromatography system coupled with mass spectrometry. Results: No differences were found for TMAO, ÎłBB, or TML concentrations between controls and VTE patients. In thrombin generation tests, TMAO, ÎłBB, and TML showed a positive correlation with lag time and time to peak. TMAO, ÎłBB, and TML negatively correlated with peak height. No significant differences were observed regarding TMAO, ÎłBB, and TML concentrations between the two blood withdrawals, nor when the control and VTE patients were analyzed separately. No correlation was observed between these gut metabolites and platelet function parameters. Conclusions: No differences were found regarding TMAO, ÎłBB, and TML concentrations between the control and VTE groups. Some correlations were found; however, they were mild or went in the opposite direction of what would be expected if TMAO and its derivatives were related to VTE risk

    Gal-1 Expression Analysis in the GLIOCAT Multicenter Study: Role as a Prognostic Factor and an Immune-Suppressive Biomarker

    Get PDF
    Glioblastoma (GBM) is the most frequent primary malignant brain tumor and has a dismal prognosis. Unfortunately, despite the recent revolution of immune checkpoint inhibitors in many solid tumors, these have not shown a benefit in overall survival in GBM patients. Therefore, new potential treatment targets as well as diagnostic, prognostic, and/or predictive biomarkers are needed to improve outcomes in this population. The beta-galactoside binding protein Galectin-1 (Gal-1) is a protein with a wide range of pro-tumor functions such as proliferation, invasion, angiogenesis, and immune suppression. Here, we evaluated Gal-1 expression by immunohistochemistry in a homogenously treated cohort of GBM (the GLIOCAT project) and correlated its expression with clinical and molecular data. We observed that Gal-1 is a negative prognostic factor in GBM. Interestingly, we observed higher levels of Gal-1 expression in the mesenchymal/classical subtypes compared to the less aggressive proneural subtype. We also observed a Gal-1 expression correlation with immune suppressive signatures of CD4 T-cells and macrophages, as well as with several GBM established biomarkers, including SHC1, PD-L1, PAX2, MEOX2, YKL-40, TCIRG1, YWHAG, OLIG2, SOX2, Ki-67, and SOX11. Moreover, Gal-1 levels were significantly lower in grade 4 IDH-1 mutant astrocytomas, which have a better prognosis. Our results confirm the role of Gal-1 as a prognostic factor and also suggest its value as an immune-suppressive biomarker in GBM

    Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

    No full text
    Objective: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bottom at 8 mm depth was reached. OMI designs were analyzed with a scan electron microscope (SEM). Results: SEM images revealed a great variation in product refinement. In the whole sample, a cylindrical OMI shape was associated with higher POS (p<0.001) but lower IT (p=0.002) values. The outer and inner OMI diameters were design characteristics well correlated with POS, IT and TF values (ranging from 0.601 to 0.961). Greater thread depth was related to greater POS values (r= 0.628), although OMIs with similar POS values may have different IT values. Thread depth and pitch had some impact on POS. TF depended mainly on the OMI inner (r= 0.961) and outer diameters (r=0.892). A thread depth to outer diameter ratio close to 40% increased TF risk. Conclusion: Although at the same insertion depth the OMI outer and inner diameters are the most important factors for primary stability, other OMI design characteristics (cylindrical vs. conical, thread design) may significantly affect primary stability and torsional fracture. This needs to be considered when selecting the appropriate OMI for the desired orthodontic procedures.Peer Reviewe