27 research outputs found

    Clinical outcomes of temporary mechanical circulatory support as a direct bridge to heart transplantation: a nationwide Spanish registry

    Get PDF
    Background: In Spain, listing for high-urgent heart transplantation is allowed for critically ill candidates not weanable from temporary mechanical circulatory support (T-MCS). We sought to analyse the clinical outcomes of this strategy. Methods and results: We conducted a case-by-case, retrospective review of clinical records of 291 adult patients listed for high-urgent heart transplantation under temporary devices from 2010 to 2015 in 16 Spanish institutions. Survival after listing and adverse clinical events were studied. At the time of listing, 169 (58%) patients were supported on veno-arterial extracorporeal membrane oxygenation (VA-ECMO), 70 (24%) on temporary left ventricular assist devices (T-LVAD) and 52 (18%) on temporary biventricular assist devices (T-BiVAD). Seven patients transitioned from VA-ECMO to temporary ventricular assist devices while on the waiting list. Mean time on T-MCS was 13.1 ± 12.6 days. Mean time from listing to transplantation was 7.6 ± 8.5 days. Overall, 230 (79%) patients were transplanted and 54 (18.6%) died during MCS. In-hospital postoperative mortality after transplantation was 33.3%, 11.9% and 26.2% for patients bridged on VA-ECMO, T-LVAD and T-BiVAD, respectively (P = 0.008). Overall survival from listing to hospital discharge was 54.4%, 78.6% and 55.8%, respectively (P = 0.002). T-LVAD support was independently associated with a lower risk of death over the first year after listing (hazard ratio 0.52, 95% confidence interval 0.30–0.92). Patients treated with VA-ECMO showed the highest incidence rate of adverse clinical events associated with T-MCS. Conclusion: Temporary devices may be used to bridge critically ill candidates directly to heart transplantation in a setting of short waiting list times, as is the case of Spain. In our series, bridging with T-LVAD was associated with more favourable outcomes than bridging with T-BiVAD or VA-ECMO

    Empleo del balón de contrapulsación intraaórtico como puente al trasplante cardiaco en España: resultados del estudio ASIS-TC

    Get PDF
    Introducción y objetivos En España, el balón de contrapulsación intraaórtico (BCIA) se ha usado frecuentemente como puente al trasplante cardiaco (TxC) urgente. El propósito es analizar los resultados de esta estrategia. Métodos Se realizó una revisión retrospectiva caso por caso de los registros clínicos de 281 pacientes adultos listados para TxC urgente asistidos con BCIA en 16 hospitales españoles entre 2010 y 2015. Se analizaron la supervivencia antes y después del trasplante y la incidencia de eventos adversos. Resultados Se trasplantó a 194 pacientes (69%; IC95%, 63, 3-74, 4) y 20 (7, 1%; IC95%, 4, 4-10, 8) fallecieron durante la asistencia, cuya duración media fue de 10, 9 ± 9, 7 días. El BCIA se explantó antes de obtener un órgano a 32 pacientes (11, 4%). En 35 pacientes (12, 5%; IC95%, 8, 8-16, 9) se implantó un dispositivo de asistencia circulatoria mecánica completa. El tiempo en la lista de espera urgente se incrementó desde 5, 9 ± 6, 3 días en 2010 hasta 15 ± 11, 7 días en 2015 (p = 0, 001). La supervivencia a 30 días y a 1 y 5 años tras el TxC fue del 88, 1% (IC95%, 85, 7-90, 5), 76% (IC95%, 72, 9-79, 1) y 67, 8% (IC95%, 63, 7-71, 9) respectivamente. La tasa de incidencia de eventos adversos mayores —disfunción del BCIA, ictus, hemorragia o infección— durante la asistencia fue de 26 (IC95%, 20, 6-32, 4) eventos/1.000 pacientes-día. La tasa de incidencia de explante del BCIA por complicaciones fue de 7, 2 (IC95%, 4, 5-10, 8) casos/1.000 pacientes-día. Conclusiones En el contexto de listas de espera cortas, el BCIA puede utilizarse como puente al TxC urgente con resultados aceptables. Esta estrategia conlleva una incidencia significativa de eventos adversos. Introduction and objectives: In Spain, intra-aortic balloon pump (IABP) has been used frequently as a bridge to urgent heart transplant (HT). We sought to analyze the clinical outcomes of this strategy. Methods: We conducted a case-by-case, retrospective review of clinical records of 281 adult patients listed for urgent HT under IABP support in 16 Spanish institutions from 2010 to 2015. Pre- and post-transplant survival and adverse clinical events were analyzed. Results: A total of 194 (69%, 95%CI, 63.3-74.4) patients were transplanted and 20 (7.1%, 95%CI, 4.4-10.8) died during a mean period of IABP support of 10.9 ± 9.7 days. IABP support was withdrawn before an organ became available in 32 (11.4%) patients. Thirty-five (12.5%, 95%CI, 8.8-16.9) patients transitioned from IABP to full-support mechanical devices. Mean urgent waiting list time increased from 5.9 ± 6.3 days in 2010 to 15 ± 11.7 days in 2015 (P =.001). Post-transplant survival rates at 30-days, 1-year, and 5-years were 88.1% (95%CI, 85.7-90.5), 76% (95%CI, 72.9-79.1), and 67.8% (95%CI, 63.7-71.9), respectively. The incidence rate of major adverse clinical outcomes—device dysfunction, stroke, bleeding or infection—during IABP support was 26 (95%CI, 20.6-32.4) episodes per 1000 patient-days. The incidence rate of IABP explantation due to complications was 7.2 (95%CI, 4.5-10.8) cases per 1000 patient-days. Conclusions: In a setting of short waiting list times, IABP can be used to bridge candidates to urgent HT with acceptable postoperative results, but there were significant rates of adverse clinical events during support. Full English text available from:www.revespcardiol.org/e

    Complicaciones infecciosas relacionadas con la asistencia circulatoria mecánica de corta duración en candidatos a trasplante cardiaco urgente

    Get PDF
    Introducción y objetivos El uso de dispositivos de asistencia circulatoria mecánica de corta duración como puente a trasplante es frecuente en España. Se desconocen la epidemiología y la repercusión de las complicaciones infecciosas en estos pacientes. Métodos Descripción sistemática de la epidemiología y análisis de la repercusión pronóstica de las complicaciones infecciosas en un registro multicéntrico retrospectivo de pacientes tratados con dispositivos de asistencia circulatoria mecánica de corta duración como puente a trasplante cardiaco urgente entre 2010 y 2015 en 16 hospitales españoles. Resultados Se estudió a 249 pacientes; 87 (34, 9%) de ellos tuvieron un total de 102 infecciones. La vía respiratoria fue la localización más frecuente (n = 47; 46, 1%). En 78 casos (76, 5%) se obtuvo confirmación microbiológica; se aislaron en total 100 gérmenes causales, con predominio de bacterias gramnegativas (n = 58, 58%). Los pacientes con complicaciones infecciosas presentaron mayor mortalidad durante el periodo de asistencia circulatoria mecánica (el 25, 3 frente al 12, 3%; p = 0, 009) y menor probabilidad de recibir un trasplante (el 73, 6 frente al 85, 2%; p = 0, 025) que los pacientes sin infección. La mortalidad posoperatoria tras el trasplante fue similar en ambos grupos (con infección, el 28, 3%; sin infección, el 23, 4%; p = 0, 471). Conclusiones Los pacientes tratados con dispositivos de asistencia circulatoria mecánica de corta duración como puente al trasplante cardiaco están expuestos a un alto riesgo de complicaciones infecciosas, las cuales se asocian con una mayor mortalidad en espera del órgano. Introduction and objectives Short-term mechanical circulatory support is frequently used as a bridge to heart transplant in Spain. The epidemiology and prognostic impact of infectious complications in these patients are unknown. Methods Systematic description of the epidemiology of infectious complications and analysis of their prognostic impact in a multicenter, retrospective registry of patients treated with short-term mechanical devices as a bridge to urgent heart transplant from 2010 to 2015 in 16 Spanish hospitals. Results We studied 249 patients, of which 87 (34.9%) had a total of 102 infections. The most frequent site was the respiratory tract (n = 47; 46.1%). Microbiological confirmation was obtained in 78 (76.5%) episodes, with a total of 100 causative agents, showing a predominance of gram-negative bacteria (n = 58, 58%). Compared with patients without infection, those with infectious complications showed higher mortality during the support period (25.3% vs 12.3%, P = .009) and a lower probability of receiving a transplant (73.6% vs 85.2%, P = .025). In-hospital posttransplant mortality was similar in the 2 groups (with infection: 28.3%; without infection: 23.4%; P = .471). Conclusions Patients supported with temporary devices as a bridge to heart transplant are exposed to a high risk of infectious complications, which are associated with higher mortality during the organ waiting period

    The CARMENES search for exoplanets around M dwarfs High-resolution optical and near-infrared spectroscopy of 324 survey stars

    Get PDF
    The CARMENES radial velocity (RV) survey is observing 324 M dwarfs to search for any orbiting planets. In this paper, we present the survey sample by publishing one CARMENES spectrum for each M dwarf. These spectra cover the wavelength range 520–1710 nm at a resolution of at least R >80 000, and we measure its RV, Hα emission, and projected rotation velocity. We present an atlas of high-resolution M-dwarf spectra and compare the spectra to atmospheric models. To quantify the RV precision that can be achieved in low-mass stars over the CARMENES wavelength range, we analyze our empirical information on the RV precision from more than 6500 observations. We compare our high-resolution M-dwarf spectra to atmospheric models where we determine the spectroscopic RV information content, Q, and signal-to-noise ratio. We find that for all M-type dwarfs, the highest RV precision can be reached in the wavelength range 700–900 nm. Observations at longer wavelengths are equally precise only at the very latest spectral types (M8 and M9). We demonstrate that in this spectroscopic range, the large amount of absorption features compensates for the intrinsic faintness of an M7 star. To reach an RV precision of 1 m s−1 in very low mass M dwarfs at longer wavelengths likely requires the use of a 10 m class telescope. For spectral types M6 and earlier, the combination of a red visual and a near-infrared spectrograph is ideal to search for low-mass planets and to distinguish between planets and stellar variability. At a 4 m class telescope, an instrument like CARMENES has the potential to push the RV precision well below the typical jitter level of 3–4 m s−1

    The CARMENES search for exoplanets around M dwarfs. Two temperate Earth-mass planet candidates around Teegarden’s Star

    Get PDF
    Context.Teegarden’s Star is the brightest and one of the nearest ultra-cool dwarfs in the solar neighbourhood. For its late spectral type (M7.0 V),the star shows relatively little activity and is a prime target for near-infrared radial velocity surveys such as CARMENES.Aims.As part of the CARMENES search for exoplanets around M dwarfs, we obtained more than 200 radial-velocity measurements of Teegarden’sStar and analysed them for planetary signals.Methods.We find periodic variability in the radial velocities of Teegarden’s Star. We also studied photometric measurements to rule out stellarbrightness variations mimicking planetary signals.Results.We find evidence for two planet candidates, each with 1.1M⊕minimum mass, orbiting at periods of 4.91 and 11.4 d, respectively. Noevidence for planetary transits could be found in archival and follow-up photometry. Small photometric variability is suggestive of slow rotationand old age.Conclusions.The two planets are among the lowest-mass planets discovered so far, and they are the first Earth-mass planets around an ultra-cooldwarf for which the masses have been determined using radial velocities.We thank the referee Rodrigo Díaz for a careful review andhelpful comments. M.Z. acknowledges support from the Deutsche Forschungs-gemeinschaft under DFG RE 1664/12-1 and Research Unit FOR2544 “BluePlanets around Red Stars”, project no. RE 1664/14-1. CARMENES isan instrument for the Centro Astronómico Hispano-Alemán de Calar Alto(CAHA, Almería, Spain). CARMENES is funded by the German Max-Planck-Gesellschaft (MPG), the Spanish Consejo Superior de InvestigacionesCientíficas (CSIC), the European Union through FEDER/ERF FICTS-2011-02 funds, and the members of the CARMENES Consortium (Max-Planck-Institut für Astronomie, Instituto de Astrofísica de Andalucía, LandessternwarteKönigstuhl, Institut de Ciències de l’Espai, Institut für Astrophysik Göttingen,Universidad Complutense de Madrid, Thüringer Landessternwarte Tautenburg,Instituto de Astrofísica de Canarias, Hamburger Sternwarte, Centro de Astro-biología and Centro Astronómico Hispano-Alemán), with additional contribu-tions by the Spanish Ministry of Economy, the German Science Foundationthrough the Major Research Instrumentation Programme and DFG ResearchUnit FOR2544 “Blue Planets around Red Stars”, the Klaus Tschira Stiftung, thestates of Baden-Württemberg and Niedersachsen, and by the Junta de Andalucía.Based on data from the CARMENES data archive at CAB (INTA-CSIC). Thisarticle is based on observations made with the MuSCAT2 instrument, devel-oped by ABC, at Telescopio Carlos Sánchez operated on the island of Tener-ife by the IAC in the Spanish Observatorio del Teide. Data were partly col-lected with the 150-cm and 90-cm telescopes at the Sierra Nevada Observa-tory (SNO) operated by the Instituto de Astrofísica de Andalucía (IAA-CSIC).Data were partly obtained with the MONET/South telescope of the MOnitoringNEtwork of Telescopes, funded by the Alfried Krupp von Bohlen und HalbachFoundation, Essen, and operated by the Georg-August-Universität Göttingen,the McDonald Observatory of the University of Texas at Austin, and the SouthAfrican Astronomical Observatory. We acknowledge financial support from theSpanish Agencia Estatal de Investigación of the Ministerio de Ciencia, Inno-vación y Universidades and the European FEDER/ERF funds through projectsAYA2015-69350-C3-2-P, AYA2016-79425-C3-1/2/3-P, AYA2018-84089, BES-2017-080769, BES-2017-082610, ESP2015-65712-C5-5-R, ESP2016-80435-C2-1/2-R, ESP2017-87143-R, ESP2017-87676-2-2, ESP2017-87676-C5-1/2/5-R, FPU15/01476, RYC-2012-09913, the Centre of Excellence ”Severo Ochoa”and ”María de Maeztu” awards to the Instituto de Astrofísica de Canarias (SEV-2015-0548), Instituto de Astrofísica de Andalucía (SEV-2017-0709), and Cen-tro de Astrobiología (MDM-2017-0737), the Generalitat de Catalunya throughCERCA programme”, the Deutsches Zentrum für Luft- und Raumfahrt throughgrants 50OW0204 and 50OO1501, the European Research Council through grant694513, the Italian Ministero dell’instruzione, dell’università de della ricerca andUniversità degli Studi di Roma Tor Vergata through FFABR 2017 and “Mis-sion: Sustainability 2016”, the UK Science and Technology Facilities Council through grant ST/P000592/1, the Israel Science Foundation through grant848/16, the Chilean CONICYT-FONDECYT through grant 3180405, the Mexi-can CONACYT through grant CVU 448248, the JSPS KAKENHI through grantsJP18H01265 and 18H05439, and the JST PRESTO through grant JPMJPR1775

    The CARMENES search for exoplanets around M dwarfs HD147379 b: A nearby Neptune in the temperate zone of an early-M dwarf

    Get PDF
    We report on the first star discovered to host a planet detected by radial velocity (RV) observations obtained within the CARMENES survey for exoplanets around M dwarfs. HD 147379 (V = 8.9 mag, M = 0.58 ± 0.08 M⊙), a bright M0.0 V star at a distance of 10.7 pc, is found to undergo periodic RV variations with a semi-amplitude of K = 5.1 ± 0.4 m s−1 and a period of P = 86.54 ± 0.06 d. The RV signal is found in our CARMENES data, which were taken between 2016 and 2017, and is supported by HIRES/Keck observations that were obtained since 2000. The RV variations are interpreted as resulting from a planet of minimum mass mP sin i = 25 ± 2 M⊕, 1.5 times the mass of Neptune, with an orbital semi-major axis a = 0.32 au and low eccentricity (e < 0.13). HD 147379 b is orbiting inside the temperate zone around the star, where water could exist in liquid form. The RV time-series and various spectroscopic indicators show additional hints of variations at an approximate period of 21.1 d (and its first harmonic), which we attribute to the rotation period of the star.FEDER/ERF FICTS-2011-02 fundsMajor Research Instrumentation Programme and DFG Research Unit FOR2544 “Blue Planets around Red StarsEuropean Research Council (ERC-279347), Deutsche Forschungsgemeinschaft (RE 1664/12-1, RE 2694/4-1), Bundesministerium für Bildung und Forschung (BMBF-05A14MG3, BMBF-05A17MG3), Spanish Ministry of Economy and Competitiveness (MINECO, grants AYA2015-68012-C2-2-P, AYA2016-79425-C3-1,2,3-P, AYA2015-69350-C3-2-P, AYA2014-54348-C03- 01, AYA2014-56359-P, AYA2014-54348-C3-2-R, AYA2016-79425-C3-3-P and 2013 Ramòn y Cajal program RYC-2013-14875), Fondo Europeo de Desarrollo Regional (FEDER, grant ESP2016-80435-C2-1-R, ESP2015-65712-C5- 5-R), Generalitat de Catalunya/CERCA programme, Spanish Ministerio de Educación, Cultura y Deporte, programa de Formación de Profesorado Universitario (grant FPU15/01476), Deutsches Zentrum für Luft- und Raumfahrt (grants 50OW0204 and 50OO1501), Office of Naval Research Global (award no. N62909-15-1-2011), Mexican CONACyT grant CB-2012-183007

    Registro Español de Trasplante Cardiaco. XXXI Informe Oficial de la Asociación de Insuficiencia Cardiaca de la Sociedad Española de Cardiología

    Get PDF
    Introducción y objetivos Se presentan las características clínicas y los resultados de los trasplantes cardiacos realizados en España con la actualización correspondiente a 2019. Métodos Se describen las características clínicas y los resultados de los trasplantes cardiacos realizados en 2019, así como las tendencias de estos en el periodo 2010-2018. Resultados En 2019 se realizaron 300 trasplantes (8.794 desde 1984; 2.745 entre 2010 y 2019). Respecto a años previos, los cambios más llamativos son el descenso hasta el 38% de los trasplantes realizados en código urgente, y la consolidación en el cambio de asistencia circulatoria pretrasplante, con la práctica desaparición del balón de contrapulsación (0, 7%), la estabilización del uso del oxigenador extracorpóreo de membrana (9, 6%) y el aumento de los dispositivos de asistencia ventricular (29%). La supervivencia en el trienio 2016-2018 es similar a la del trienio 2013-2015 (p = 0, 34), y ambas mejores que la del trienio 2010-2012 (p = 0, 002 y p = 0, 01 respectivamente). Conclusiones Se mantienen estables tanto la actividad del trasplante cardiaco en España como los resultados en supervivencia en los últimos 2 trienios. Hay una tendencia a realizar menos trasplantes urgentes, la mayoría con dispositivos de asistencia ventricular. Introduction and objectives: The present report describes the clinical characteristics and outcomes of heart transplants in Spain and updates the data to 2019. Methods: We describe the clinical characteristics and outcomes of heart transplants performed in Spain in 2019, as well as trends in this procedure from 2010 to 2018. Results: In 2019, 300 transplants were performed (8794 since 1984; 2745 between 2010 and 2019). Compared with previous years, the most notable findings were the decreasing rate of urgent transplants (38%), and the consolidation of the type of circulatory support prior to transplant, with an almost complete disappearance of counterpulsation balloon (0.7%), stabilization in the use of extracorporeal membrane oxygenation (9.6%), and an increase in the use of ventricular assist devices (29.0%). Survival from 2016 to 2018 was similar to that from 2013 to 2015 (P = .34). Survival in both these periods was better than that from 2010 to 2012 (P = .002 and P = .01, respectively). Conclusions: Heart transplant activity has remained stable during the last few years, as have outcomes (in terms of survival). There has been a trend to a lower rate of urgent transplants and to a higher use of ventricular assist devices prior to transplant

    The CARMENES search for exoplanets around M dwarfs. First visual-channel radial-velocity measurements and orbital parameter updates of seven M-dwarf planetary systems

    Get PDF
    Stars and planetary system

    Utilidad de los biomarcadores sAXL, cTnT-us, GDF15 y Lp-PLA2 en la predicción de eventos cardiovasculares en receptores de un trasplante cardiaco

    No full text
    Trabajo presentado en el IV Congreso de la Sociedad Española de Trasplante (SET), celebrado en Santander, España, del 2 al 8 de mayo de 2016Peer Reviewe

    Utility of sAXL, hs-cTnT, Lp-PLA2, GDF-15 Biomarkers and Th1/Treg Ratio in the Detection of Cardiac Allograft Vasculopathy

    No full text
    Trabajo presentado en el 36th Annual Meeting and Scientific Sessions of the International-Society-for-Heart-and-Lung-Transplantation (ISHLT), celebrado en Washington, Estados Unidos, del 27 al 30 de abril de 2016Peer Reviewe