445 research outputs found

    Surface Reconstruction and Decahedral Structure of Bimetallic Nanoparticles

    Get PDF
    We report on energetic surface reconstruction phenomena observed on bimetallic nanoparticle systems of AuPd and AuCu, similar to a resolidification effect observed during the cooling process in lead clusters. These binary alloy nanoparticles show the fivefold edges truncated, resulting in { 100 } facets on decahedral structures, an effect largely envisioned and reported theoretically, with no experimental evidence so far. We demonstrate experimentally as well as by computational simulations that this new eutectic structure is favored in such nanoalloy systems.Fil: Rodríguez López J. L.. Instituto Potosino de Investigación Científica y Tecnológica ; MéxicoFil: Montejano Carrizales, J. M.. Universidad Autónoma de San Luis Potosí; MéxicoFil: Pal, U.. Universidad Auto´noma de Puebla; MéxicoFil: Sánchez Ramírez, J. F.. Universidad Auto´noma de Puebla; MéxicoFil: Troiani, Horacio Esteban. Comision Nacional de Energía Atómica. Gerencia de Área Investigaciones y Aplicaciones no Nucleares. Gerencia de Física (Centro Atómico Bariloche). División Física de Metales; ArgentinaFil: García, D.. The University of Texas; Estados UnidosFil: Miki Yoshida, M.. The University of Texas; Estados UnidosFil: José Yacamán, Miguel. The University of Texas; Estados Unido

    Gastric cancer screening by combined assay for serum anti-Helicobacter pylori IgG antibody and serum pepsinogen levels — “ABC method”

    Get PDF
    The current status of screening for gastric cancer-risk (gastritis A, B, C, D) method using combined assay for serum anti-Helicobacter pylori (Hp) IgG antibody and serum pepsinogen (PG) levels, “ABC method”, was reviewed and the latest results of our ongoing trial are reported. It was performed using the following strategy: Subjects were classified into 1 of 4 risk groups based on the results of the two serologic tests, anti-Hp IgG antibody titers and the PG I and II levels: Group A [Hp(−)PG(−)], infection-free subjects; Group B [Hp(+)PG(−)], chronic atrophic gastritis (CAG) free or mild; Group C [Hp(+)PG(+)], CAG; Group D [Hp(−)PG(+)]), severe CAG with extensive intestinal metaplasia. Continuous endoscopic follow-up examinations are required to detect early stages of gastric cancer. Asymptomatic Group A, which accounts for 50–80% of all the subjects may be excluded from the secondary endoscopic examination, from the viewpoint of efficiency. Hp-infected subjects should be administered eradication treatment aimed at the prevention of gastric cancer

    Phospho-Smad3 signaling is predictive biomarker for hepatocellular carcinoma risk assessment in primary biliary cholangitis patients

    Get PDF
    Introduction: Patients with primary biliary cholangitis (PBC) are at increased risk for development of hepatocellular carcinoma (HCC), particularly in the presence of comorbidities such as excessive alcohol consumption. Although liver fibrosis is an important risk factor for HCC development, earlier predictors of future HCC development in livers with little fibrosis are needed but not well defined. The transforming growth factor (TGF)-β/Smad signaling pathway participates importantly in hepatic carcinogenesis. Phosphorylated forms (phospho-isoforms) in Smad-related pathways can transmit opposing signals: cytostatic C-terminally-phosphorylated Smad3 (pSmad3C) and carcinogenic linker-phosphorylated Smad3 (pSmad3L) signals. Methods and results: To assess the balance between Smad signals as a biomarker of risk, we immunohistochemically compared Smad domain-specific Smad3 phosphorylation patterns among 52 PBC patients with various stages of fibrosis and 25 non-PBC patients with chronic hepatitis C virus infection. HCC developed in 7 of 11 PBC patients showing high pSmad3L immunoreactivity, but in only 2 of 41 PBC patients with low pSmad3L. In contrast, 9 of 20 PBC patients with minimal Smad3C phosphorylation developed HCC, while HCC did not occur during follow-up in 32 patients who retained hepatic tumor-suppressive pSmad3C. Further, PBC patients whose liver specimens showed high pSmad3L positivity were relatively likely to develop HCC even when little fibrosis was evident. Conclusion: In this study, Smad phospho-isoform status showed promise as a biomarker predicting likelihood of HCC occurrence in PBC. Eventually, therapies to shift favorably Smad phospho-isoforms might decrease likelihood of PBC-related HCC

    Design and Initial Performance of the Askaryan Radio Array Prototype EeV Neutrino Detector at the South Pole

    Full text link
    We report on studies of the viability and sensitivity of the Askaryan Radio Array (ARA), a new initiative to develop a Teraton-scale ultra-high energy neutrino detector in deep, radio-transparent ice near Amundsen-Scott station at the South Pole. An initial prototype ARA detector system was installed in January 2011, and has been operating continuously since then. We report on studies of the background radio noise levels, the radio clarity of the ice, and the estimated sensitivity of the planned ARA array given these results, based on the first five months of operation. Anthropogenic radio interference in the vicinity of the South Pole currently leads to a few-percent loss of data, but no overall effect on the background noise levels, which are dominated by the thermal noise floor of the cold polar ice, and galactic noise at lower frequencies. We have also successfully detected signals originating from a 2.5 km deep impulse generator at a distance of over 3 km from our prototype detector, confirming prior estimates of kilometer-scale attenuation lengths for cold polar ice. These are also the first such measurements for propagation over such large slant distances in ice. Based on these data, ARA-37, the 200 km^2 array now under construction, will achieve the highest sensitivity of any planned or existing neutrino detector in the 10^{16}-10^{19} eV energy range.Comment: 25 pages, 37 figures, this version with improved ice attenuation length analysis; for submission to Astroparticle Physic

    Constraints on the Ultra-High Energy Neutrino Flux from Gamma-Ray Bursts from a Prototype Station of the Askaryan Radio Array

    Get PDF
    We report on a search for ultra-high-energy (UHE) neutrinos from gamma-ray bursts (GRBs) in the data set collected by the Testbed station of the Askaryan Radio Array (ARA) in 2011 and 2012. From 57 selected GRBs, we observed no events that survive our cuts, which is consistent with 0.12 expected background events. Using NeuCosmA as a numerical GRB reference emission model, we estimate upper limits on the prompt UHE GRB neutrino fluence and quasi-diffuse flux from 10710^{7} to 101010^{10} GeV. This is the first limit on the prompt UHE GRB neutrino quasi-diffuse flux above 10710^{7} GeV.Comment: 14 pages, 8 figures, Published in Astroparticle Physics Journa

    First Constraints on the Ultra-High Energy Neutrino Flux from a Prototype Station of the Askaryan Radio Array

    Get PDF
    The Askaryan Radio Array (ARA) is an ultra-high energy (>1017>10^{17} eV) cosmic neutrino detector in phased construction near the South Pole. ARA searches for radio Cherenkov emission from particle cascades induced by neutrino interactions in the ice using radio frequency antennas (150800\sim150-800 MHz) deployed at a design depth of 200 m in the Antarctic ice. A prototype ARA Testbed station was deployed at 30\sim30 m depth in the 2010-2011 season and the first three full ARA stations were deployed in the 2011-2012 and 2012-2013 seasons. We present the first neutrino search with ARA using data taken in 2011 and 2012 with the ARA Testbed and the resulting constraints on the neutrino flux from 1017102110^{17}-10^{21} eV.Comment: 26 pages, 15 figures. Since first revision, added section on systematic uncertainties, updated limits and uncertainty band with improvements to simulation, added appendix describing ray tracing algorithm. Final revision includes a section on cosmic ray backgrounds. Published in Astropart. Phys.

    Performance of two Askaryan Radio Array stations and first results in the search for ultra-high energy neutrinos

    Get PDF
    Ultra-high energy neutrinos are interesting messenger particles since, if detected, they can transmit exclusive information about ultra-high energy processes in the Universe. These particles, with energies above 1016eV10^{16}\mathrm{eV}, interact very rarely. Therefore, detectors that instrument several gigatons of matter are needed to discover them. The ARA detector is currently being constructed at South Pole. It is designed to use the Askaryan effect, the emission of radio waves from neutrino-induced cascades in the South Pole ice, to detect neutrino interactions at very high energies. With antennas distributed among 37 widely-separated stations in the ice, such interactions can be observed in a volume of several hundred cubic kilometers. Currently 3 deep ARA stations are deployed in the ice of which two have been taking data since the beginning of the year 2013. In this publication, the ARA detector "as-built" and calibrations are described. Furthermore, the data reduction methods used to distinguish the rare radio signals from overwhelming backgrounds of thermal and anthropogenic origin are presented. Using data from only two stations over a short exposure time of 10 months, a neutrino flux limit of 3106GeV/(cm2 s sr)3 \cdot 10^{-6} \mathrm{GeV} / (\mathrm{cm^2 \ s \ sr}) is calculated for a particle energy of 10^{18}eV, which offers promise for the full ARA detector.Comment: 21 pages, 34 figures, 1 table, includes supplementary materia

    IceRay: An IceCube-centered Radio-Cherenkov GZK Neutrino Detector

    Get PDF
    We discuss design considerations and simulation results for IceRay, a proposed large-scale ultra-high energy (UHE) neutrino detector at the South Pole. The array is designed to detect the coherent Askaryan radio emission from UHE neutrino interactions in the ice, with the goal of detecting the cosmogenic neutrino flux with reasonable event rates. Operating in coincidence with the IceCube neutrino detector would allow complete calorimetry of a subset of the events. We also report on the status of a testbed IceRay station which incorporates both ANITA and IceCube technology and will provide year-round monitoring of the radio environment at the South Pole.Comment: 5 pages, 7 figures; Proceedings of ARENA 2008, to be published in Nucl. Inst. and Meth.

    SHARAQ Project: Progress in 2009

    Get PDF
    On March 23, 2009, the first beam was successfullytransported to the final focal plane of the SHARAQspectrometer. We investigated detector responses toheavy-ion beams and the ion optical properties ofthe SHARAQ spectrometer1) and the high-resolutionbeam line2) in the subsequent commissioning runs andfound that the system as a whole worked almost as perits design. The first physics run with the spectrometerwas performed in November 2009. In this article, wereview the progress in the SHARAQ project in 2009
    corecore