163 research outputs found
Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for the measurement of aortic PWV
Consistency of aortic distensibility and pulse wave velocity estimates with respect to the Bramwell-Hill theoretical model: a cardiovascular magnetic resonance study
<p>Abstract</p> <p>Background</p> <p>Arterial stiffness is considered as an independent predictor of cardiovascular mortality, and is increasingly used in clinical practice. This study aimed at evaluating the consistency of the automated estimation of regional and local aortic stiffness indices from cardiovascular magnetic resonance (CMR) data.</p> <p>Results</p> <p>Forty-six healthy subjects underwent carotid-femoral pulse wave velocity measurements (<it>CF_PWV</it>) by applanation tonometry and CMR with steady-state free-precession and phase contrast acquisitions at the level of the aortic arch. These data were used for the automated evaluation of the aortic arch pulse wave velocity (<it>Arch_PWV</it>), and the ascending aorta distensibility (<it>AA_Distc, AA_Distb)</it>, which were estimated from ascending aorta strain (<it>AA_Strain</it>) combined with either carotid or brachial pulse pressure. The local ascending aorta pulse wave velocity <it>AA_PWVc </it>and <it>AA_PWVb </it>were estimated respectively from these carotid and brachial derived distensibility indices according to the Bramwell-Hill theoretical model, and were compared with the <it>Arch_PWV</it>. In addition, a reproducibility analysis of <it>AA_PWV </it>measurement and its comparison with the standard <it>CF_PWV </it>was performed. Characterization according to the Bramwell-Hill equation resulted in good correlations between <it>Arch_PWV </it>and both local distensibility indices <it>AA_Distc </it>(r = 0.71, p < 0.001) and <it>AA_Distb </it>(r = 0.60, p < 0.001); and between <it>Arch_PWV </it>and both theoretical local indices <it>AA_PWVc </it>(r = 0.78, p < 0.001) and <it>AA_PWVb </it>(r = 0.78, p < 0.001). Furthermore, the <it>Arch_PWV </it>was well related to <it>CF_PWV </it>(r = 0.69, p < 0.001) and its estimation was highly reproducible (inter-operator variability: 7.1%).</p> <p>Conclusions</p> <p>The present work confirmed the consistency and robustness of the regional index <it>Arch_PWV </it>and the local indices <it>AA_Distc and AA_Distb </it>according to the theoretical model, as well as to the well established measurement of <it>CF_PWV</it>, demonstrating the relevance of the regional and local CMR indices.</p
Towards an international language for incontinence-associated dermatitis (IAD): design and evaluation of psychometric properties of the Ghent Global IAD Categorization Tool (GLOBIAD) in 30 countries
Background Incontinence-associated dermatitis (IAD) is a specific type of irritant contact dermatitis with different severity levels. An internationally accepted instrument to assess the severity of IAD in adults, with established diagnostic accuracy, agreement and reliability, is needed to support clinical practice and research. Objectives To design the Ghent Global IAD Categorization Tool (GLOBIAD) and evaluate its psychometric properties.
Methods The design was based on expert consultation using a three-round Delphi procedure with 34 experts from 13 countries. The instrument was tested using IAD photographs, which reflected different severity levels, in a sample of 823 healthcare professionals from 30 countries. Measures for diagnostic accuracy (sensitivity and specificity), agreement, interrater reliability (multirater Fleiss kappa) and intrarater reliability (Cohen’s kappa) were assessed. Results The GLOBIAD consists of two categories based on the presence of persistent redness (category 1) and skin loss (category 2), both of which are subdivided based on the presence of clinical signs of infection. The agreement for differentiating between category 1 and category 2 was 0 86 [95% confidence interval (CI) 0 86–0 87], with a sensitivity of 90% and a specificity of 84%. The overall agreement was 0 55 (95% CI 0 55–0 56). The Fleiss kappa for differentiating between category 1 and category 2 was 0 65 (95% CI 0 65–0 65). The overall Fleiss kappa was 0 41 (95% CI 0 41–0 41). The Cohen’s kappa for differentiating between category 1 and category 2 was 0 76 (95% CI 0 75–0 77). The overall Cohen’s kappa was 0 61 (95% CI 0 59–0 62). Conclusions The development of the GLOBIAD is a major step towards a better systematic assessment of IAD in clinical practice and research worldwide. However, further validation is needed.info:eu-repo/semantics/acceptedVersio
Bramwell-Hill modeling for local aortic pulse wave velocity estimation: a validation study with velocity-encoded cardiovascular magnetic resonance and invasive pressure assessment
<p>Abstract</p> <p>Background</p> <p>The Bramwell-Hill model describes the relation between vascular wall stiffness expressed in aortic distensibility and the pulse wave velocity (PWV), which is the propagation speed of the systolic pressure wave through the aorta. The main objective of this study was to test the validity of this model locally in the aorta by using PWV-assessments based on in-plane velocity-encoded cardiovascular magnetic resonance (CMR), with invasive pressure measurements serving as the gold standard.</p> <p>Methods</p> <p>Seventeen patients (14 male, 3 female, mean age ± standard deviation = 57 ± 9 years) awaiting cardiac catheterization were prospectively included. During catheterization, intra-arterial pressure measurements were obtained in the aorta at multiple locations 5.8 cm apart. PWV was determined regionally over the aortic arch and locally in the proximal descending aorta. Subsequently, patients underwent a CMR examination to measure aortic PWV and aortic distention. Distensibility was determined locally from the aortic distension at the proximal descending aorta and the pulse pressure measured invasively during catheterization and non-invasively from brachial cuff-assessment. PWV was determined regionally in the aortic arch using through-plane and in-plane velocity-encoded CMR, and locally at the proximal descending aorta using in-plane velocity-encoded CMR. Validity of the Bramwell-Hill model was tested by evaluating associations between distensibility and PWV. Also, theoretical PWV was calculated from distensibility measurements and compared with pressure-assessed PWV.</p> <p>Results</p> <p>In-plane velocity-encoded CMR provides stronger correlation (p = 0.02) between CMR and pressure-assessed PWV than through-plane velocity-encoded CMR (r = 0.69 versus r = 0.26), with a non-significant mean error of 0.2 ± 1.6 m/s for in-plane versus a significant (p = 0.006) error of 1.3 ± 1.7 m/s for through-plane velocity-encoded CMR. The Bramwell-Hill model shows a significantly (p = 0.01) stronger association between distensibility and PWV for local assessment (r = 0.8) than for regional assessment (r = 0.7), both for CMR and for pressure-assessed PWV. Theoretical PWV is strongly correlated (r = 0.8) with pressure-assessed PWV, with a statistically significant (p = 0.04) mean underestimation of 0.6 ± 1.1 m/s. This theoretical PWV-estimation is more accurate when invasively-assessed pulse pressure is used instead of brachial cuff-assessment (p = 0.03).</p> <p>Conclusions</p> <p>CMR with in-plane velocity-encoding is the optimal approach for studying Bramwell-Hill associations between local PWV and aortic distensibility. This approach enables non-invasive estimation of local pulse pressure and distensibility.</p
The relationship between subtypes of depression and cardiovascular disease: a systematic review of biological models
A compelling association has been observed between cardiovascular disease (CVD) and depression, suggesting individuals with depression to be at significantly higher risk for CVD and CVD-related mortality. Systemic immune activation, hypothalamic–pituitary–adrenal (HPA) axis hyperactivity, arterial stiffness and endothelial dysfunction have been frequently implicated in this relationship. Although a differential epidemiological association between CVD and depression subtypes is evident, it has not been determined if this indicates subtype specific biological mechanisms. A comprehensive systematic literature search was conducted using PubMed and PsycINFO databases yielding 147 articles for this review. A complex pattern of systemic immune activation, endothelial dysfunction and HPA axis hyperactivity is suggestive of the biological relationship between CVD and depression subtypes. The findings of this review suggest that diagnostic subtypes rather than a unifying model of depression should be considered when investigating the bidirectional biological relationship between CVD and depression. The suggested model of a subtype-specific biological relationship between depression and CVDs has implications for future research and possibly for diagnostic and therapeutic processes
Using a modified Delphi methodology to gain consensus on the use of dressings in chronic wounds management
Objective: Managing chronic wounds is associated with a burden to patients, caregivers, health services and society and there is a lack of clarity regarding the role of dressings in improving outcomes. This study aimed to provide understanding on a range of topics, including: the definition of chronicity in wounds, the burden of illness, clinical outcomes of reducing healing time and the impact of early interventions on clinical and economic outcomes and the role of matrix metalloproteinases (MMPs) in wound healing. Method: A systematic review of the literature was carried out on the role of dressings in diabetic foot ulcer (DFU), and venous leg ulcer (VLU) management strategies, their effectiveness, associated resource use/cost, and quality of life (QoL) impact on patients. From this evidence-base statements were written regarding chronicity in wounds, burden of illness, healing time, and the role of MMPs, early interventions and dressings. A modified Delphi methodology involving two iterations of email questionnaires followed by a face-to-face meeting was used to validate the statements, in order to arrive at a consensus for each. Clinical experts were selected, representing nurses, surgeons, podiatrists, academics, and policy experts. Results: In the first round, 38/47 statements reached or exceeded the consensus threshold of 80% and none were rejected. According to the protocol, any statement not confirmed or rejected had to be modified using the comments from participants and resubmitted. In the second round, 5/9 remaining statements were confirmed and none rejected, leaving 4 to discuss at the meeting. All final statements were confirmed with at least 80% consensus. Conclusion: This modified Delphi panel sought to gain clarity from clinical experts surrounding the use of dressings in the management of chronic wounds. A full consensus statement was developed to help clinicians and policy makers improve the management of patients with these conditions
Developments in silicone technology for use in stoma care
YesSoft silicone's flexibility, adhesive capacity and non-toxic, non-odourous and hypoallergenic nature have made it an established material for adhesive and protective therapeutic devices. In wound care, silicone is a component of contact layer dressings for superficial wounds and silicone gel sheeting for reducing the risk of scarring, as well as of barriers for incontinence-associated dermatitis. Regarding stoma accessories, silicone is established in barrier films to prevent contact dermatitis, adhesive removers to prevent skin stripping and filler gels to prevent appliance leaks. Until recently, silicone has not been used in stoma appliances flanges, as its hydrophobic nature has not allowed for moisture management to permit trans-epidermal water loss and prevent maceration. Traditional hydrocolloid appliances manage moisture by absorbing water, but this can lead to saturation and moisture-associated skin damage (MASD), as well as increased adhesion and resultant skin tears on removal, known as medical adhesive-related skin injury (MARSI). However, novel silicone compounds have been developed with a distinct evaporation-based mechanism of moisture management. This uses colloidal separation to allow the passage of water vapour at a rate equivalent to normal trans-epidermal water loss. It has been shown to minimise MASD, increase wear time and permit atraumatic removal without the use of adhesive solvents. Trio Healthcare has introduced this technology with a range of silicone-based flange extenders and is working with the University of Bradford Centre for Skin Sciences on prototype silicone-based stoma appliance flanges designed to significantly reduce the incidence of peristomal skin complications, such as MARSI and MASD. It is hoped that this will also increase appliance wear time, reduce costs and improve patient quality of life
- …