62 research outputs found

    Refrigeration System for the ATLAS Experiment

    Get PDF
    The proposed ATLAS detector for the 27 km circumference LHC collider is of unprecedented size and complexity. The magnet configuration is based on an inner superconducting solenoid and large superconducting air-core toroids (barrel and two end-caps) each made of eight coils symmetrically arranged outside the calorimetry. The total cold mass approaches 600 tons and the stored energy is 1.7 GJ. The cryogenic infrastructure will include a 6 kW @ 4.5 K refrigerator, a precooling unit and distribution systems and permits flexible operation during cool-down, normal running and quench recovery. A dedicated LN2 refrigeration system is proposed for the three liquid argon calorimeters (84 m3 of LAr). Magnets and calorimeters will be individually tested prior to their definitive installation in a large scale cryogenic test area on the surface. The experiment is scheduled to be operational in 2005

    First Cool-down and Test at 4.5 K of the ATLAS Superconducting Barrel Toroid Assembled in the LHC Experimental Cavern

    Get PDF
    The large ATLAS superconducting magnets system consists of the Barrel, two End-Caps Toroids and the Central Solenoid. The eight separate coils making the Barrel Toroid (BT) have been individually tested with success in a dedicated surface test facility in 2004 and 2005 and afterwards assembled in the underground cavern of the ATLAS experiment. In order to fulfil all the cryogenic scenarios foreseen for these magnets with a cold mass of 370 tons, two separate helium refrigerators and a complex helium distribution system have been used. This paper describes the results of the first cool-down, steady-state operation at 4.5 K and quench recovery of the BT in its final configuration

    Assembly Concept and Technology of the ATLAS Barrel Toroid

    Get PDF

    Mechanical behavior of the ATLAS B0 model coil

    Get PDF
    The ATLAS B0 model coil has been developed and constructed to verify the design parameters and the manufacture techniques of the Barrel Toroid coils (BT) that are under construction for the ATLAS Detector. Essential for successful operation is the mechanical behavior of the superconducting coil and its support structure. In the ATLAS magnet test facility, a magnetic mirror is used to reproduce in the model coil the electromagnetic forces of the BT coils when assembled in the final Barrel Toroid magnet system. The model coil is extensively equipped with mechanical instrumentation to monitor stresses and force levels as well as contraction during a cooling down and excitation up to nominal current. The installed set up of strain gauges, position sensors and capacitive force transducers is presented. Moreover the first mechanical results in terms of expected main stress, strain and deformation values are presented based on detailed mechanical analysis of the design. (7 refs)

    In Silico Selection and In Vitro Evaluation of New Molecules That Inhibit the Adhesion of <i>Streptococcus mutants</i> through Antigen I/II

    Get PDF
    Streptococcus mutans is the main early colonizing cariogenic bacteria because it recognizes salivary pellicle receptors. The Antigen I/II (Ag I/II) of S. mutans is among the most important adhesins in this process, and is involved in the adhesion to the tooth surface and the bacterial co-aggregation in the early stage of biofilm formation. However, this protein has not been used as a target in a virtual strategy search for inhibitors. Based on the predicted binding affinities, drug-like properties and toxicity, molecules were selected and evaluated for their ability to reduce S. mutans adhesion. A virtual screening of 883,551 molecules was conducted; cytotoxicity analysis on fibroblast cells, S. mutans adhesion studies, scanning electron microscopy analysis for bacterial integrity and molecular dynamics simulation were also performed. We found three molecules ZINC19835187 (ZI-187), ZINC19924939 (ZI-939) and ZINC19924906 (ZI-906) without cytotoxic activity, which inhibited about 90% the adhesion of S. mutans to polystyrene microplates. Molecular dynamic simulation by 300 nanoseconds showed stability of the interaction between ZI-187 and Ag I/II (PDB: 3IPK). This work provides new molecules that targets Ag I/II and have the capacity to inhibit in vitro the S. mutans adhesion on polystyrene microplates

    ATLAS B0 toroid model coil test at CERN

    Get PDF
    The ATLAS superconducting magnet system consists of a Barrel Toroid, two End-Cap Toroids and a Central Solenoid. The Barrel Toroid, with overall dimensions of 20-m diameter by 26-m length, is made of eight individual coils symmetrically assembled around the central axis with a warm structure. The system is presently under construction in industry. In order to verify the construction concepts a model coil B0, a 9-m short version of a single Barrel Toroid coil, was built. Since April 2001, an extensive test program is underway at CERN to characterize the mechanical, thermal, electrical and magnetic properties of the coil. The magnet successfully achieved the 20-kA nominal operating current in July 2001. The test program and the main results are reported. (9 refs)
    • …
    corecore