19 research outputs found

    Programa de Excelência em Gestão: o caso da Frísia Cooperativa Agroindustrial

    Get PDF
    This case study addresses the application of the Management Excellence Program at Frísia Cooperativa Agroindustrial, using the Cooperative Management Development Program tool (PDGC), which is based on the Management Excellence Model (MEG) of the National Quality Foundation (FNQ). We evaluate the applicability of the tool which makes a diagnosis of the governance and management structure of the cooperative and aims at continuous improvement in each PDCL (Plan, Do, Check, and Learn) cycle. In order to get more information, we carried out a semi-structured interview with the governance agents of Frísia. The data (made available by SESCOOP-PR, with the consent of the cooperative) refers to the PDGC cycles of 2017 and 2018. Results show that the SESCOOP Cooperative Governance Index (ISGC) increased from 63.3% in 2017 to 87.0% in 2018, as well as the SESCOOP Management Index (ISG), which increased from 50.3% in 2017 to 69.4% in 2018.Este estudo de caso aborda a aplicação do Programa de Excelência em Gestão na Frísia Cooperativa Agroindustrial, utilizando a ferramenta do Programa de Desenvolvimento da Gestão das Cooperativas (PDGC), que faz um diagnóstico da governança e da gestão da cooperativa, visando à melhoria contínua a cada ciclo de planejamento, execução, controle e aprendizado. Foram disponibilizados dados pelo SESCOOP-PR, com anuência da cooperativa, referente aos ciclos do PDGC dos anos de 2017 e 2018. Verificou-se que o Índice SESCOOP de Governança Cooperativista (ISGC) passou de 63,3% em 2017 para 87,0% em 2018. E o Índice SESCOOP de Gestão (ISG) passou de 50,3% em 2017 para 69,4% em 2018. Para complementar as informações, foi realizada uma entrevista semiestruturada com os agentes de governança da Frísia. A análise dos resultados indica que uma estrutura de governança capaz de integrar as diferentes partes interessadas tem efeitos práticos na efetividade da gestão da cooperativa.

    Pervasive gaps in Amazonian ecological research

    Get PDF

    Pervasive gaps in Amazonian ecological research

    Get PDF
    Biodiversity loss is one of the main challenges of our time,1,2 and attempts to address it require a clear un derstanding of how ecological communities respond to environmental change across time and space.3,4 While the increasing availability of global databases on ecological communities has advanced our knowledge of biodiversity sensitivity to environmental changes,5–7 vast areas of the tropics remain understudied.8–11 In the American tropics, Amazonia stands out as the world’s most diverse rainforest and the primary source of Neotropical biodiversity,12 but it remains among the least known forests in America and is often underrepre sented in biodiversity databases.13–15 To worsen this situation, human-induced modifications16,17 may elim inate pieces of the Amazon’s biodiversity puzzle before we can use them to understand how ecological com munities are responding. To increase generalization and applicability of biodiversity knowledge,18,19 it is thus crucial to reduce biases in ecological research, particularly in regions projected to face the most pronounced environmental changes. We integrate ecological community metadata of 7,694 sampling sites for multiple or ganism groups in a machine learning model framework to map the research probability across the Brazilian Amazonia, while identifying the region’s vulnerability to environmental change. 15%–18% of the most ne glected areas in ecological research are expected to experience severe climate or land use changes by 2050. This means that unless we take immediate action, we will not be able to establish their current status, much less monitor how it is changing and what is being lostinfo:eu-repo/semantics/publishedVersio

    Pervasive gaps in Amazonian ecological research

    Get PDF
    Biodiversity loss is one of the main challenges of our time,1,2 and attempts to address it require a clear understanding of how ecological communities respond to environmental change across time and space.3,4 While the increasing availability of global databases on ecological communities has advanced our knowledge of biodiversity sensitivity to environmental changes,5,6,7 vast areas of the tropics remain understudied.8,9,10,11 In the American tropics, Amazonia stands out as the world's most diverse rainforest and the primary source of Neotropical biodiversity,12 but it remains among the least known forests in America and is often underrepresented in biodiversity databases.13,14,15 To worsen this situation, human-induced modifications16,17 may eliminate pieces of the Amazon's biodiversity puzzle before we can use them to understand how ecological communities are responding. To increase generalization and applicability of biodiversity knowledge,18,19 it is thus crucial to reduce biases in ecological research, particularly in regions projected to face the most pronounced environmental changes. We integrate ecological community metadata of 7,694 sampling sites for multiple organism groups in a machine learning model framework to map the research probability across the Brazilian Amazonia, while identifying the region's vulnerability to environmental change. 15%–18% of the most neglected areas in ecological research are expected to experience severe climate or land use changes by 2050. This means that unless we take immediate action, we will not be able to establish their current status, much less monitor how it is changing and what is being lost

    Evaluation of cerebral hemodynamics using the Doppler ultrasonography technique and its correlations with variations of intracranial pressure in an animal model of intracranial hypertension

    No full text
    Introdução: O aumento da pressão intracraniana (PIC) é um problema comum na prática neurocirúrgica, e a monitoração invasiva deste parâmetro faz parte da rotina de unidades de terapia intensiva. O Doppler transcraniano vem sendo testado na avaliação da hemodinâmica cerebral como parâmetro de avaliação não invasiva da PIC, porém há controvérsias na literatura sobre seu real benefício e utilidade nesta situação. Este estudo objetivou correlacionar os dados de avaliação do fluxo sanguíneo cerebral através da técnica de Doppler com as variações da monitoração invasiva da PIC na fase aguda de hipertensão intracraniana em um modelo animal. Métodos: Trata-se de um estudo experimental realizado em suínos. O experimento constou de dois grupos de animais (A e B) com hipertensão intracraniana gerada por insuflação com soro fisiológico de um balão no parênquima cerebral, sendo o grupo A com 4 mL e o grupo B com 7 mL. Nos dois grupos houve uma intervenção clínica com infusão de solução salina a 3% e uma simulação de intervenção cirúrgica (desinsuflação do balão). Em todos os momentos de insuflação do balão e das intervenções foram registrados os valores dos monitores de PIC e do Doppler: velocidades sistólica (VS), diastólica (VD), média (VM) do fluxo sanguíneo cerebral e índice de pulsatilidade (IP). Foram realizadas comparações do comportamento dos parâmetros avaliados pela ultrassonografia Doppler craniana (VS, VD, VM e IP) em relação às variações da PIC intraparenquimatosa. Resultados: Foram estudados 20 suínos sendo 10 no grupo A e 10 no grupo B. Um animal do grupo B foi excluído do estudo, pois foi a óbito antes do término do experimento. Após a insuflação do balão, como era de se esperar, a PIC no grupo B foi superior à do grupo A em todos os momentos, até a desinsuflação do mesmo. Realizada a correlação de Spearman observou-se correlação significativa entre IP e PIC, principalmente logo após insuflação do balão, ou seja, na elevação abrupta da PIC. Não houve correlação entre a PIC e os parâmetros VS, VD e VM. Também não houve variação significativa da PIC após infusão endovenosa de solução salina hipertônica. Conclusão: Este resultado demonstra o potencial do IP como bom parâmetro de avaliação de pacientes com suspeita de elevação hiperaguda e recente da PIC. Não se conseguiu demonstrar os mesmos resultados de correlação entre a PIC e as demais variáveis VS, VD e VM. Diante destes achados, adicionados aos dados conflitantes da literatura disponível até o momento, não se recomenda, por enquanto, a utilização desses parâmetros isoladamente como substitutos da monitoração invasiva da PIC, evidenciando a necessidade de mais estudos clínicos e experimentaisIntroduction: Increased intracranial pressure (ICP) is a common problem in neurosurgical practice. Invasive monitoring of ICP in these cases is part of the intensive care unit routine. Transcranial Doppler has been tested in the evaluation of cerebral hemodynamics as a non-invasive evaluation of ICP, but there are controversies in the literature about its real benefit and usefulness in this situation. Thus, this study aimed to correlate the data of cerebral blood flow assessment using the Doppler technique and the invasive monitoring of ICP in the acute phase of intracranial hypertension in an animal model. Methods: This is an experimental study in pigs. During the experiment, an intracerebral expansive mass with an inflatable balloon was simulated. The experiment consisted of two groups (A and B) of animals with intracranial hypertension generated by a ballon inflation inside the cerebral parenchima, group A with 4 mL and group B with 7 mL. In both groups there was a clinical intervention with infusion of 3% saline solution and a simulation of surgical intervention (balloon drain out). The values of ICP and Doppler parameters (systolic (FVs), diastolic (FVd), and mean (FVm) cerebral blood flow velocities) were collected at all moments of balloon inflation and interventions, as well as the pulsatility index (PI). Comparisons of the behavior of the parameters evaluated by Doppler ultrasound (FVs, FVd, FVm and PI) were performed in relation to intraparenchymal ICP. Results: Twenty pigs were studied, 10 in group A and 10 in group B. One pig died in group B and it was excluded. After balloon inflation, as expected, ICP in group B was higher than in group A at all times, until the ballon was empty again. Significant correlation between PI and ICP was obtained when Spearman correlation was performed, mainly shortly after balloon inflation, that is, in the abrupt elevation of ICP. There was no correlation between ICP and FVs, FVd or FVm. There was also no significant change in ICP after intravenous infusion of hypertonic saline solution. Conclusion: These results demonstrate the potential of PI as a good parameter for the evaluation of patients with suspected ICP elevation. It was not possible to demonstrate the same correlation results between the ICP and FVs, FVd or FVm. Due to these results and also to the literature conflicting data to date, the use of these parameters alone as substitutes for the invasive monitoring of ICP is not recommended until now, which shows the need for further clinical and experimental studie

    Evaluation of cerebral hemodynamics using the Doppler ultrasonography technique and its correlations with variations of intracranial pressure in an animal model of intracranial hypertension

    No full text
    Introdução: O aumento da pressão intracraniana (PIC) é um problema comum na prática neurocirúrgica, e a monitoração invasiva deste parâmetro faz parte da rotina de unidades de terapia intensiva. O Doppler transcraniano vem sendo testado na avaliação da hemodinâmica cerebral como parâmetro de avaliação não invasiva da PIC, porém há controvérsias na literatura sobre seu real benefício e utilidade nesta situação. Este estudo objetivou correlacionar os dados de avaliação do fluxo sanguíneo cerebral através da técnica de Doppler com as variações da monitoração invasiva da PIC na fase aguda de hipertensão intracraniana em um modelo animal. Métodos: Trata-se de um estudo experimental realizado em suínos. O experimento constou de dois grupos de animais (A e B) com hipertensão intracraniana gerada por insuflação com soro fisiológico de um balão no parênquima cerebral, sendo o grupo A com 4 mL e o grupo B com 7 mL. Nos dois grupos houve uma intervenção clínica com infusão de solução salina a 3% e uma simulação de intervenção cirúrgica (desinsuflação do balão). Em todos os momentos de insuflação do balão e das intervenções foram registrados os valores dos monitores de PIC e do Doppler: velocidades sistólica (VS), diastólica (VD), média (VM) do fluxo sanguíneo cerebral e índice de pulsatilidade (IP). Foram realizadas comparações do comportamento dos parâmetros avaliados pela ultrassonografia Doppler craniana (VS, VD, VM e IP) em relação às variações da PIC intraparenquimatosa. Resultados: Foram estudados 20 suínos sendo 10 no grupo A e 10 no grupo B. Um animal do grupo B foi excluído do estudo, pois foi a óbito antes do término do experimento. Após a insuflação do balão, como era de se esperar, a PIC no grupo B foi superior à do grupo A em todos os momentos, até a desinsuflação do mesmo. Realizada a correlação de Spearman observou-se correlação significativa entre IP e PIC, principalmente logo após insuflação do balão, ou seja, na elevação abrupta da PIC. Não houve correlação entre a PIC e os parâmetros VS, VD e VM. Também não houve variação significativa da PIC após infusão endovenosa de solução salina hipertônica. Conclusão: Este resultado demonstra o potencial do IP como bom parâmetro de avaliação de pacientes com suspeita de elevação hiperaguda e recente da PIC. Não se conseguiu demonstrar os mesmos resultados de correlação entre a PIC e as demais variáveis VS, VD e VM. Diante destes achados, adicionados aos dados conflitantes da literatura disponível até o momento, não se recomenda, por enquanto, a utilização desses parâmetros isoladamente como substitutos da monitoração invasiva da PIC, evidenciando a necessidade de mais estudos clínicos e experimentaisIntroduction: Increased intracranial pressure (ICP) is a common problem in neurosurgical practice. Invasive monitoring of ICP in these cases is part of the intensive care unit routine. Transcranial Doppler has been tested in the evaluation of cerebral hemodynamics as a non-invasive evaluation of ICP, but there are controversies in the literature about its real benefit and usefulness in this situation. Thus, this study aimed to correlate the data of cerebral blood flow assessment using the Doppler technique and the invasive monitoring of ICP in the acute phase of intracranial hypertension in an animal model. Methods: This is an experimental study in pigs. During the experiment, an intracerebral expansive mass with an inflatable balloon was simulated. The experiment consisted of two groups (A and B) of animals with intracranial hypertension generated by a ballon inflation inside the cerebral parenchima, group A with 4 mL and group B with 7 mL. In both groups there was a clinical intervention with infusion of 3% saline solution and a simulation of surgical intervention (balloon drain out). The values of ICP and Doppler parameters (systolic (FVs), diastolic (FVd), and mean (FVm) cerebral blood flow velocities) were collected at all moments of balloon inflation and interventions, as well as the pulsatility index (PI). Comparisons of the behavior of the parameters evaluated by Doppler ultrasound (FVs, FVd, FVm and PI) were performed in relation to intraparenchymal ICP. Results: Twenty pigs were studied, 10 in group A and 10 in group B. One pig died in group B and it was excluded. After balloon inflation, as expected, ICP in group B was higher than in group A at all times, until the ballon was empty again. Significant correlation between PI and ICP was obtained when Spearman correlation was performed, mainly shortly after balloon inflation, that is, in the abrupt elevation of ICP. There was no correlation between ICP and FVs, FVd or FVm. There was also no significant change in ICP after intravenous infusion of hypertonic saline solution. Conclusion: These results demonstrate the potential of PI as a good parameter for the evaluation of patients with suspected ICP elevation. It was not possible to demonstrate the same correlation results between the ICP and FVs, FVd or FVm. Due to these results and also to the literature conflicting data to date, the use of these parameters alone as substitutes for the invasive monitoring of ICP is not recommended until now, which shows the need for further clinical and experimental studie

    Intramedullary spinal teratoma: a rare condition with a good outcome Teratoma intramedular: bom resultado em caso incomum

    No full text
    Approximately one-third of spinal tumors in child-hood1 are intramedullary neoplasms1 and up to 80 % are gliomas2. The occurrence of teratomas in the spine is ex-tremely rare3. Except for in the sacrococcygeal region, teratomas constitute less than 0.5 % of all intraspinal tu-mors. It is believed that they arise from multipotential germinal cells misplaced in the early embryonic develop-ment. It was also proposed that teratomas represent abor-tive “twin ” formation cystic component ependymal diver-ticula of the central canal of the spinal cord4,5. Teratomas may be intra- or extramedullary and usually fill the spinal canal. Some teratomas have been reported in association with split cord malformations and other developmental spinal abnormalities, like myelomeningoceles3,6,7. The tu-mor may be partially solid or wholly cystic. Intramedul
    corecore