260 research outputs found

    Optimization of multivariate analysis for IACT stereoscopic systems

    Full text link
    Multivariate methods have been recently introduced and successfully applied for the discrimination of signal from background in the selection of genuine very-high energy gamma-ray events with the H.E.S.S. Imaging Atmospheric Cerenkov Telescope. The complementary performance of three independent reconstruction methods developed for the H.E.S.S. data analysis, namely Hillas, model and 3D-model suggests the optimization of their combination through the application of a resulting efficient multivariate estimator. In this work the boosted decision tree method is proposed leading to a significant increase in the signal over background ratio compared to the standard approaches. The improved sensitivity is also demonstrated through a comparative analysis of a set of benchmark astrophysical sources.Comment: 10 pages, 8 figures, 3 tables, accepted for publication in Astroparticle Physic

    Carbon and nitrogen stable isotope fractionation during abiotic hydrolysis of pesticides

    Get PDF
    Compound-specific Stable Isotope Analysis (CSIA) has been recently established as a tool to study pesticide degradation in the environment. Among degradative processes, hydrolysis is environmentally relevant as it can be chemically or enzymatically mediated. Here, CSIA was used to examine stable carbon and nitrogen isotope fractionation during abiotic hydrolysis of legacy or currently used pesticides (chloroacetanilide herbicides: Acetochlor, Alachlor, S-Metolachlor and Butachlor, acylalanine fungicide: Metalaxyl, and triazine herbicide: Atrazine). Degradation products analysis and Csingle bondN dual-CSIA allowed to infer hydrolytic degradation pathways from carbon and nitrogen isotopic fractionation. Carbon isotopic fractionation for alkaline hydrolysis revealed similar apparent kinetic isotope effects (AKIEC = 1.03–1.07) for the 6 pesticides, which were consistent with SN2 type nucleophilic substitutions. Neither enantio-selectivity (EF ≈ 0.5) nor enantio-specific isotope fractionation occurred during hydrolysis of R (AKIEC = 1.04 ± 0.01) and S (AKIEC = 1.04 ± 0.02) enantiomers of a racemic mixture of Metalaxyl. Dual element isotope plots enabled to tease apart Csingle bondCl bond breaking of alkane (Λ ≈ εN/εC ≈ 0, Acetochlor, Butachlor) and aromatic π-system (Λ ≈ 0.2, Atrazine) from Csingle bondO bond breaking by dealkylation (Λ ≈ 0.9, Metalaxyl). Reference values for abiotic versus biotic SN2 reactions derived from carbon and nitrogen CSIA may be used to untangle pesticide degradation pathways and evaluate in situ degradation during natural and engineered remediation

    Removing krypton from xenon by cryogenic distillation to the ppq level

    Get PDF
    The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β\beta-emitter 85^{85}Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentration of natural krypton in xenon nat\rm{^{nat}}Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 1015^{-15} mol/mol) is required. In this work, the design of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4\cdot105^5 with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of nat\rm{^{nat}}Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN

    Search for Two-Neutrino Double Electron Capture of 124^{124}Xe with XENON100

    Get PDF
    Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For 124^{124}Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of 124^{124}Xe using 7636 kg\cdotd of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life T1/2>6.5×1020T_{1/2}>6.5\times10^{20} yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and find a sensitivity of T1/2>6.1×1022T_{1/2}>6.1\times10^{22} yr after an exposure of 2 t\cdotyr.Comment: 6 pages, 4 figure

    Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    Get PDF
    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.Comment: 10 pages, 5 figure

    Search for Event Rate Modulation in XENON100 Electronic Recoil Data

    Get PDF
    We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.Comment: 6 pages, 4 figure

    ULF geomagnetic pulsations at different latitudes in Antarctica

    Get PDF
    We present a study aimed to characterize the ULF (1–100 mHz) geomagnetic pulsation activity in the polar cap at different latitudes. We used magnetic measurements obtained through 2005–2007 in Antarctica, at Dome C (89&amp;deg; S corrected geomagnetic latitude) and at Terra Nova Bay (80&amp;deg; S corrected geomagnetic latitude). The results indicate a solar wind control of the wave activity, more important at larger distances from the cusp, as well as a significant role of the local ionospheric conditions. The different position of the two stations, with respect to the cusp and closed field lines, is responsible for the observed different pulsation characteristics. At Terra Nova Bay, due to the approaching of the station to the cusp and closed field lines in the daytime, the ULF power is characterized by a maximum around noon; daytime pulsation events in the Pc5 frequency band are related to the fundamental field line resonances occurring at lower latitudes, while higher harmonics of the fundamental may account for the characteristics of Pc3–4 pulsations. In the nighttime, at Pc3 frequencies, the results suggest waves propagating sunward, possibly due to the transmission of upstream waves from the magnetosheath via the magnetotail lobes. At Dome C, near the geomagnetic pole and very far from closed field lines, the ULF power in any frequency band only shows an enhancement in the postmidnight sector, more pronounced for Pc3 pulsations. The ULF activity appears to be driven by processes occurring in the magnetotail: in particular, nighttime Pc3 pulsation events may be originated from upstream wave penetration through the magnetotail lobes

    Search for Coherent Elastic Scattering of Solar ⁸B Neutrinos in the XENON1T Dark Matter Experiment

    Get PDF
    We report on a search for nuclear recoil signals from solar 8B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 to 1.6  keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant 8B neutrinolike excess is found in an exposure of 0.6  t×y. For the first time, we use the nondetection of solar neutrinos to constrain the light yield from 1–2 keV nuclear recoils in liquid xenon, as well as nonstandard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 and 11  GeV c−2 by as much as an order of magnitude

    Search for inelastic scattering of WIMP dark matter in XENON1T

    Get PDF
    We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off 129Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV deexcitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.83 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2σ. A profile-likelihood ratio analysis is used to set upper limits on the cross section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100  GeV/c2, with the strongest upper limit of 3.3×10−39  cm2 for 130  GeV/c2 WIMPs at 90% confidence level
    corecore