9 research outputs found

    Microbiological and Molecular Characterization of Staphylococcus hominis Isolates from Blood

    No full text
    Background: The incidence of coagulase-negative staphylococci reported as causative agents of nosocomial infections has risen in the last decade. The aim of this study was to characterize biofilm formation, antibiotic resistance, SCCmec type, and genetic relatedness in clinical isolates of Staphylococcus cohnii, Staphylococcus hominis, and Staphylococcus sciuri recovered from humans. Methods: Clinically relevant isolates of S. cohnii (n = 15), S. hominis (n = 9), and S. sciuri (n = 6), were collected from patients. Biofilm formation was evaluated using crystal violet staining, drug susceptibility was assessed using the broth microdilution method, and methicillin resistance was measured using the cefoxitin disk test. SCCmec was typed using 2 different methodologies, and genetic relatedness was determined by pulsed-field gel electrophoresis (PFGE). Results: Sixty percent (9/15) of S. cohnii, 33% (3/9) of S. hominis, and 50% (3/6) of S. sciuri isolates were categorized as weak producers of biofilm. None of the isolates were resistant to vancomycin or linezolid. All 3 species showed a high resistance (> 66%) to ampicillin, levofloxacin, erythromycin, and ceftriaxone, and the majority of the isolates were methicillin-resistant. PFGE revealed that the S. cohnii isolates comprised 1 dominant clone. Conclusions: The S. cohnii, S. hominis, and S. sciuri isolates analyzed in this study showed a high methicillin resistance and resistance to other antimicrobials. The results of this study strongly suggest that coagulase-negative staphylococci harbour new SCCmec elements. We report the first case of a clone of S. cohnii associated with human disease. " 2011 Informa Healthcare.",,,,,,"10.3109/00365548.2011.598873",,,"http://hdl.handle.net/20.500.12104/42807","http://www.scopus.com/inward/record.url?eid=2-s2.0-80755130173&partnerID=40&md5=75f3fa0437e9a5b2e2c9627c48a1ae84",,,,,,"11-dic",,"Scandinavian Journal of Infectious Diseases",,"93

    Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

    No full text
    International audienceFeedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. We discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64-0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x/Nb microstrip at 100 mK and over the frequency range 200-350 GHz, which is comparable to values previously reported in the literature

    Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

    No full text
    Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. We discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64−0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiNx /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature

    Search for Supersymmetry with a dominant R-Parity violating LQDLQ\overline{D} Coupling in e+ee^+ e^- Collisions at centre-of-mass energies of 130 GeV to 172 GeV

    No full text
    A search for pair-production of supersymmetric particles under the assumption that R-parity is violated via a dominant LQDbar coupling has been performed using the data collected by ALEPH at centre-of-mass energies of 130-172 GeV. The observed candidate events in the data are in agreement with the Standard Model expectation. This result is translated into lower limits on the masses of charginos, neutralinos, sleptons, sneutrinos and squarks. For instance, for m_0=500 GeV/c^2 and tan(beta)=sqrt(2) charginos with masses smaller than 81 GeV/c^2 and neutralinos with masses smaller than 29 GeV/c^2 are excluded at the 95% confidence level for any generation structure of the LQDbar coupling

    A Study of Single W Production in e+ee^{+}e^{-} Collisions at s\sqrt{s} = 161 - 183 GeV

    No full text
    Single W production is studied in the data recorded with the ALEPH detector at LEP at centre-of-mass energies between 161 and 183 GeV. The cross section is measured to be sigma_W=0.41+-0.17 (stat) +-0.04 (syst) pb at 183 GeV, consistent with the Standard Model expectation. Limits on non-standard WWgamma couplings are deduced as -1.6 < kg < 1.5 (lg=0) and -1.6 < lg < 1.6 (kg=1) at 95% C.L. A search for effectively invisible decays of the W boson in W pair production is performed, leading to an upper limit on the branching ratio of 1.3% (\Gamma_inv= 27 MeV) at 95% C.L

    Technical Design Report on Forward Detectors:FMD, T0 and V0.

    No full text
    corecore