133 research outputs found

    Polyhydroxyalkanoates production from methane emissions in Sphagnum mosses: Assessing the effect of temperature and phosphorus limitation

    Get PDF
    Producción CientíficaThe isolation of highly efficient methanotrophic communities is crucial for the optimization of methane bioconversion into products with a high market value such as polyhydroxyalkanoates (PHA). The research here presented aimed at enriching a methanotrophic consortium from two different inocula (Sphagnum peat moss (Sp) and Sphagnum and activated sludge (M)) able to accumulate PHA while efficiently oxidizing CH4. Moreover, the effect of the temperature and phosphorus limitation on the biodegradation rate of CH4 and the PHA accumulation potential was investigated. Higher CH4 degradation rates were obtained under P availability at increasing temperature (25, 30 and 37 °C). The biomass enriched from the mixed inoculum always exhibited a superior biodegradation performance regardless of the temperature (a maximum value of 84.3 ± 8.4 mg CH4 h−1 g biomass−1 was recorded at 37 °C). The results of the PHB production showed that phosphorus limitation is required to promote PHB accumulation, the highest PHB content being observed with the Sphagnum inoculum at 25 °C (13.6 ± 5.6%). The differential specialization of the microbial communities depending on the enrichment temperature supported the key role of this parameter on the results obtained. In all cases after the completion of the enrichment process and of the P limitation tests, Methylocystis, a type II methanotroph known for its ability to accumulate PHA, was the genus that became dominant (reaching percentages from 16 to 46% depending on the enrichment temperature). Thus, the results here obtained demonstrated for the first time the relevance of the temperature used for the enrichment of the methanotrophic bacteria to boost PHA production yields under P limiting condition, highlighting the importance of optimizing culture conditions to improve the cost-efficiency of bioprocesses based on using methane as the primary feedstock for the PHA industrial market.Ministerio de Economía, Industria y Competitividad - FEDER (Project CTM2015-73228-JIN)Junta de Castilla y León (programa de apoyo a proyectos de investigación - Ref. UIC 71 and CLU 2017-09

    Influence of key operational parameters on biohydrogen production from fruit and vegetable waste via lactate-driven dark fermentation

    Get PDF
    Producción CientíficaThis study aims at investigating the influence of operational parameters on biohydrogen production from fruit-vegetable waste (FVW) via lactate-driven dark fermentation. Mesophilic batch fermentations were conducted at different pH (5.5, 6.0, 6.5, 7.0, and non-controlled), total solids (TS) contents (5, 7, and 9%) and initial cell biomass concentrations (18, 180, and 1800 mg VSS/L). Higher hydrogen yields and rates were attained with more neutral pH values and low TS concentrations, whereas higher biomass densities enabled higher production rates and avoided wide variations in hydrogen production. A marked lactate accumulation (still at neutral pH) in the fermentation broth was closely associated with hydrogen inhibition. In contrast, enhanced hydrogen productions matched with much lower lactate accumulations (even it was negligible in some fermentations) along with the acetate and butyrate co-production but not with carbohydrates removal. At pH 7, 5% TS, and 1800 mg VSS/L, 49.5 NmL-H2/g VSfed and 976.4 NmL-H2/L-h were attained.Junta de Castilla y Leon - Fondo Europeo de Desarrollo Regional (grants CLU 2017-09, CL-EI-2021-07 and UIC 315

    A methodology for the calculation of typical gas concentration values and sampling intervals in the power transformers of a distribution system operator†

    Get PDF
    Predictive maintenance strategies in power transformers aim to assess the risk through the calculation and monitoring of the health index of the power transformers. The parameter most used in predictive maintenance and to calculate the health index of power transformers is the dissolved gas analysis (DGA). The current tendency is the use of online DGA monitoring equipment while continuing to perform analyses in the laboratory. Although the DGA is well known, there is a lack of published experimental data beyond that in the guides. This study used the nearest-rank method for obtaining the typical gas concentration values and the typical rates of gas increase from a transformer population to establish the optimal sampling interval and alarm thresholds of the continuous monitoring devices for each power transformer. The percentiles calculated by the nearest-rank method were within the ranges of the percentiles obtained using the R software, so this simple method was validated for this study. The results obtained show that the calculated concentration limits are within the range of or very close to those proposed in IEEE C57.104-2019 and IEC 60599:2015. The sampling intervals calculated for each transformer were not correct in all cases since the trend of the historical DGA samples modified the severity of the calculated intervals.This work was partially financed by the EU Regional Development Fund (FEDER) and the Spanish Government under RETOS-COLABORACIÓN RTC-2017-6782-3 and by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 864579 (FLEXIGRID)

    Fault location in low-voltage distribution networks based on reflectometry - a case study

    Get PDF
    Fault location can help transport and distribution system operators in their effort of minimizing supply interruption times. Nowadays, fault location devices are widely extended in the transport grid. However, the application of these solutions to distribution networks is not a feasible option due to the high cost of this equipment. Therefore, current research is focussed on costeffective fault location techniques which are adapted to electrical distribution networks. This paper presents results of a case study, conducted with detailed simulation models of two actual low-voltage (LV) distribution grids, using PSCAD software. One is a typical rural grid with long aerial lines, while the other is a typical urban grid with shorter line lengths which are mostly installed underground. The analysis is focussed on fault location based on travelling wave theory and reflectometry methods. The simulations include distributed parameter line models and a signal injector, in order to analyse the singular effects in the waveform which are caused by the special features of the LV network. It is shown that LV networks have some unique features which are not present in medium and highvoltage grids, which makes effective fault location more challenging. Observed issues are discussed and future work is proposed in order to overcome some of them.This research was funded by the “Ministerio de Ciencia, Innovación y Universidades – Agencia Estatal de Investigación” grant number “RTC-2017-6782-3” and the European Union FEDER funds with name “LOcalización de averías, monitorización de estado y Control en redes de bAja TEnsión—LOCATE”

    Determination of transformer oil contamination from the OLTC gases in the power transformers of a distribution system operator

    Get PDF
    Power transformers are considered to be the most important assets in power substations. Thus, their maintenance is important to ensure the reliability of the power transmission and distribution system. One of the most commonly used methods for managing the maintenance and establishing the health status of power transformers is dissolved gas analysis (DGA). The presence of acetylene in the DGA results may indicate arcing or high-temperature thermal faults in the transformer. In old transformers with an on-load tap-changer (OLTC), oil or gases can be filtered from the OLTC compartment to the transformer?s main tank. This paper presents a method for determining the transformer oil contamination from the OLTC gases in a group of power transformers for a distribution system operator (DSO) based on the application of the guides and the knowledge of experts. As a result, twenty-six out of the 175 transformers studied are defined as contaminated from the OLTC gases. In addition, this paper presents a methodology based on machine learning techniques that allows the system to determine the transformer oil contamination from the DGA results. The trained model achieves an accuracy of 99.76% in identifying oil contamination.This work was partially financed by the EU Regional Development Fund (FEDER) and the Spanish Government under RETOS-COLABORACIÓN RTC-2017-6782-3 and by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 864579 (FLEXIGRID)

    A comparative between IEEE and EN in the transformer derating when supplying nonsinusoidal load current. A practical case

    Get PDF
    Nowadays, power quality is a challenge for the distribution companies since the new energy policies are directed to a distributed generation system with power electronic based technologies. The reduction of distribution transformers capability when supplying nonsinusoidal load currents has a major impact within capacity reduction in distribution networks produced by technical losses. IEEE Std C57.110-2018, EN- 50464-3 and EN-50541-2 define procedures to derate transformers when supplying nonsinusoidal load currents. The aim of this paper is to compare these procedures through a real case distribution transformer that suffers problems due to high levels of current distortion.This research was funded by the “Ministerio de Ciencia, Innovación y Universidades – Agencia Estatal de Investigación” grant number “RTC-2017-6782-3”, the European Union FEDER funds with name “LOcalización de averías, monitorización de estado y Control en redes de bAja TEnsión—LOCATE” and the Horizon 2020 Program by the European Comision with project reference No 864579, H2020-LC-SC3-2019-ES-SCC

    Power quality impact of a small wind energy conversion system connected to the LV grid

    Get PDF
    This research work is devoted to the study of the Power Quality (PQ) impact of small wind energy conversion systems (SWECS) connected to the low voltage grid. A common coupling point (CCP) has been monitored using a PQ meter that fulfils the standard IEC 61000-4-30 class A. The PQ survey has been conducted with and without the SWECS and the results were compared with the limits defined by the standard EN 50160.This research work was supported by the Spanish Goverment under grant number ENE2007-68032-C04-04, Cantabria Goverment under the R+D 2009 initiative and SONKYO Group

    Distributed vs. spot temperature measurements in dynamic rating of overhead power lines

    Get PDF
    The increase of global energy demand and new ways of electricity production are two of the main challenges for the power sector. The electric market has to address the addition of new and renewable sources of energy to the energy mix and to be able to integrate them into the grid, while maintaining the principles of robustness, security and reliability. All of these changes point to the creation of smart grids, in which advanced generation, information and communication technologies are needed. An accurate knowledge of the electric grid state is crucial for operating the line as efficiently as possible and one of the most important grid parameters to be measured and controlled is the temperature of the overhead conductors due to their relation with the maximum allowable sag of the line and its thermal limit (annealing). This paper presents the results of real-time monitoring of an overhead power line using a distributed temperature sensing system (DTS) and compares these results with spot temperature measurements in order to estimate the loss of accuracy of having less thermal information. This comparison has been carried out in a 30 km long distributed temperature sensing system with fiber optic inside a LA-455 conductor and 6 weather stations placed along the line. An area of influence is defined for each weather station corresponding to the orography of the surroundings. The spot temperatures are obtained from the DTS in the nearest point from the weather stations assuming these six locations to be the ones where the spot temperature measurement equipment would be located. The main conclusion is that, in the case of study, spot measurements are enough to obtain a good approximation of the average temperature of the line conductor

    Seasonal variation of biogas upgrading coupled with digestate treatment in an outdoors pilot scale algal-bacterial photobioreactor

    Get PDF
    Producción CientíficaThe yearly variations of the quality of the upgraded biogas and the efficiency of digestate treatment were evaluated in an outdoors pilot scale high rate algal pond (HRAP) interconnected to an external absorption column (AC) via a conical settler. CO2 concentrations in the upgraded biogas ranged from 0.7% in August to 11.9% in December, while a complete H2S removal was achieved regardless of the operational month. CH4 concentrations ranged from 85.2% in December to 97.9% in June, with a limited O2 and N2 stripping in the upgraded biogas mediated by the low recycling liquid/biogas ratio in the AC. Biomass productivity ranged from 0.0 g m−2 d−1 in winter to 22.5 g m−2 d−1 in summer. Finally, microalgae diversity was severely reduced throughout the year likely due to the increasing salinity in the cultivation broth of the HRAP induced by process operation in the absence of effluent.INCOVER - Innovative Eco-Technologies for Resource Recovery from Wastewater (689242

    A comparison of different methodologies for rating definition in overhead lines

    Get PDF
    The grid integration of renewable energy supposes an important problem to deal with for Distributor System Operators (DSO). Distributor and transmission system operators have been using static rates for a long time to manage electric systems. Currently operators deal with one, annual, static rate or four, seasonal, static rates. This paper is devoted to the analysis of a real case of ampacity management in a 132 kV overhead line for the purpose of stablishing new static rates based on different temporal intervals.This work was supported by the Spanish Government under the R+D initiative INNPACTO with reference IPT-2011-1447-920000 and Spanish R+D initiative with reference ENE2013-42720-