12 research outputs found

    Percepções e estimulações elétricas por correntes senoidais

    Get PDF
    OBJECTIVE: To analyze the relationship between perceptions and electrical senoidal current stimulation (ESCS). METHOD: The study population comprise 100 healthy volunteers. ESCS of 5 Hz and 2 kHz were applied to the left index finger at one and 1.5 sensory threshold. Following each stimulus train a list of eight words (four related to thin fiber sensations and four related to thick fiber sensations) was presented to the subjects who were asked to choose the three words closer to the experienced sensation. Each chosen word was given a score 1; final results were obtained by the sum of the scores for the words related to thin and thick fiber systems for each situation. RESULTS: For 5 Hz ESCS at one and 1.5 sensory threshold thin fibers had significantly higher scores than thick fibers; for 2 kHz ESCS, thick fibers had significantly higher scores. CONCLUSION: These results show that there is a relation between different sensations and ESCS of different frequencies.OBJETIVO: Estudar a relação entre as sensações evocadas por estimulação elétrica por corrente senoidal (ESCS). MÉTODO: 100 voluntários normais foram estudados. ESCS a 5 Hz e 2 kHz foram aplicadas no dedo indicador esquerdo com uma e 1,5 vezes o limiar sensorial. Listas de oito palavras (4 relacionadas a fibras grossas, 4 a fibras finas) foram apresentadas após cada estimulação e foi solicitado que o sujeito escolhesse as 3 palavras que mais se aproximassem das sensações experimentadas. Às palavras escolhidas foi dado o escore 1. Os resultados finais para análise foram obtidos da soma dos escores para as palavras relacionadas aos diferentes sistemas de fibras. RESULTADOS: Para ESCS a 5 Hz sensações relacionadas a fibras finas foram significantemente mais escolhidas, já para estimulações a 2 kHz sensações relacionadas a fibras grossas foram significantemente mais escolhidas. CONCLUSÃO: Estes resultados mostram um relação entre diferentes percepções e diferentes freqüências de correntes elétricas senoidais.City of São Paulo UniversityUNIFESP Neurology and Neurosurgery DepartmentFederal University of Minas Gerais Electrical Engineering DepartmentUNIFESP, Neurology and Neurosurgery DepartmentSciEL

    Clinical assessment of spasticity in individuals with spinal cord injury

    Get PDF
    OBJECTIVE: To evaluate the effect of neuromuscular electrical stimulation on spasticity in patients with spinal cord injury. METHODS: The study included eleven subjects with spinal cord injuries (C4 to T5). The modified Ashworth scale and pendulum test, which is accomplished through the Pendular Test Device - PTD (equipment which has a quartz crystal transducer accelerometer and optic fiber flexible electrogoniometer measuring the tensions and angular displacements). Patients underwent neuromuscular electrical stimulation (NMES) to the quadriceps muscle from fibular nerve, and the tests were administered before and after therapy. RESULTS: The data show a decrease in spasticity after NMES, with features such as increasead variation between maximum and minimum peaks, i.e. increased amplitude of the curves. Furthermore, data from the subjective scale, and modified Ashworth scale after neuromuscular electrical stimulation also showed a reduction in the values of spasticity. CONCLUSION: The data suggest that NMES is effective in reducing spasticity immediately after completion. Level of Evidence II, Therapeutic Studies-Investigating the Results of Treatment.OBJETIVO: Avaliar o efeito da estimulação elétrica neuromuscular na espasticidade nos pacientes com lesão medular. MÉTODOS: Participaram do estudo onze sujeitos lesados medulares (C4 a T5). Foram utilizados para esta avaliação a escala modificada de Ashworth e o teste pendular, que foi realizado através do Dispositivo de Teste Pendular - DTP (o equipamento possui um acelerômetro de transdutores de cristais de quartzo e eletrogoniômetro de fibra óptica flexível que mede as tensões e os deslocamentos angulares). Os pacientes realizaram estimulação elétrica neuromuscular (EENM) nos músculos quadríceps e nervo fibular, sendo que os testes foram aplicados antes e após o procedimento. RESULTADOS: Os dados mostram uma diminuição da espasticidade após a EENM, com características tais como um aumento na variação entre o pico máximo e o mínimo, ou seja, aumento da amplitude das curvas. Além disso, os dados da escala subjetiva, e escala modificada de Ashworth, após a estimulação elétrica neuromuscular também apresentaram uma redução nos valores da espasticidade. CONCLUSÃO: Os dados sugerem que a EENM é eficaz para reduzir a espasticidade imediatamente após a sua realização. Nível de Evidência II, Estudos Terapêuticos -Investigação dos Resultados do Tratamento.31031

    Validation of Deep Learning techniques for quality augmentation in diffusion MRI for clinical studies

    Get PDF
    The objective of this study is to evaluate the efficacy of deep learning (DL) techniques in improving the quality of diffusion MRI (dMRI) data in clinical applications. The study aims to determine whether the use of artificial intelligence (AI) methods in medical images may result in the loss of critical clinical information and/or the appearance of false information. To assess this, the focus was on the angular resolution of dMRI and a clinical trial was conducted on migraine, specifically between episodic and chronic migraine patients. The number of gradient directions had an impact on white matter analysis results, with statistically significant differences between groups being drastically reduced when using 21 gradient directions instead of the original 61. Fourteen teams from different institutions were tasked to use DL to enhance three diffusion metrics (FA, AD and MD) calculated from data acquired with 21 gradient directions and a b-value of 1000 s/mm2. The goal was to produce results that were comparable to those calculated from 61 gradient directions. The results were evaluated using both standard image quality metrics and Tract-Based Spatial Statistics (TBSS) to compare episodic and chronic migraine patients. The study results suggest that while most DL techniques improved the ability to detect statistical differences between groups, they also led to an increase in false positive. The results showed that there was a constant growth rate of false positives linearly proportional to the new true positives, which highlights the risk of generalization of AI-based tasks when assessing diverse clinical cohorts and training using data from a single group. The methods also showed divergent performance when replicating the original distribution of the data and some exhibited significant bias. In conclusion, extreme caution should be exercised when using AI methods for harmonization or synthesis in clinical studies when processing heterogeneous data in clinical studies, as important information may be altered, even when global metrics such as structural similarity or peak signal-to-noise ratio appear to suggest otherwise

    Improvement and clinical application of an equipment designed to evaluate spasticity in spinal cord injured patients

    No full text
    Orientador: Alberto Cliquet JúniorDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências MédicasResumo: Neste projeto é apresentada uma proposta de um sistema completo para coletar, processar e analisar sinais resultantes do teste pendular, com a finalidade de avaliar a espasticidade na prática clínica. Comumente apresentado por lesados medulares, a espasticidade pode ser quantificada pela análise dos sinais de ângulo da articulação do joelho e de vibração do quadríceps durante o balanço, monitorados por um eletrogoniômetro e um acelerômetro triaxial, respectivamente. O acompanhamento de cinco pacientes, durante o programa de reabilitação, permitiu estabelecer uma relação entre os indicadores calculados, evidenciando uma relação positiva entre índice de relaxamento - R2n, razão de amplitude - R1, valor quadrático médio ¿ RMS e envoltórias do sinal para casos de espasticidade severa. Comprova-se assim a maior aplicabilidade do acelerômetro nestes casos, e a possibilidade de utilização do acelerômetro no teste pendular para quantificação da espasticidade como forma complementarAbstract: In this project is presented a proposal of a complete system to acquire, process and analyze pendulum test signals, aiming to assess spasticity in clinical practice. Often presented by spinal cord injured people, spasticity can be quantified by signals of knee joint angle and quadriceps vibration during the swing, monitored by an electrogoniometer and a triaxial accelerometer, respectively. Five patients following, through the rehabilitation program, made possible to establish a relation between relaxation index - R2n, amplitude ratio - R1, root mean square (RMS) and wrapped signals to severe spasticity. Thus, it is confirmed that, in these cases, accelerometer is more efficient and its feasibility is ratified as a possibility in pendulum test to quantify spasticityMestradoFisiopatologia CirúrgicaMestra em Ciência

    "Exigua pars est vitae qua vivimus. Ceterum quidem omne spatium non vita sed tempus est” : divagazioni semantiche (e lessicali) su spatium e sui suoi esiti romanzi

    No full text
    diasistema latino, attestato in tutta la discretio della lingua che ci è dato conoscere dai testi, spatium manifesta una sorta di liminarità concettuale con tempus che solo a partire da un certo momento si scioglie nella complementarità dell’estensione spaziale e di quella temporale. Muovendo da questi presupposti, questo contributo cercherà di evidenziare la complessa stratificazione semantica di questa lessia di basilare importanza giacché connessa con categorie fondanti per l’esperienza umana tanto dal punto di vista cognitivo, tanto da quello linguistico e pragmatico. Esaurito l’excursus interno al latino si guarderà allora alla continuazione romanza, per cercare di capire se e in quale parte del lessico permangano tracce di quell’originaria complessità di spatium risolta probabilmente prima a livello “lessicografico” che semantico-concettuale
    corecore