57 research outputs found

    A spectrograph instrument concept for the Prime Focus Spectrograph (PFS) on Subaru Telescope

    Full text link
    We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380 nm to 1300 nm. The requirements for the instrument are summarized in Section 1. We present the optical design and the optical performance and analysis in Section 2. Section 3 introduces the mechanical design, its requirements and the proposed concepts. Finally, the AIT phases for the Spectrograph System are described in Section 5.Comment: 8 pages, 5 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)

    Visible camera cryostat design and performance for the SuMIRe Prime Focus Spectrograph (PFS)

    Full text link
    We describe the design and performance of the SuMIRe Prime Focus Spectrograph (PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed ground-based spectrograph consisting of four identical spectrograph modules, each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the prime focus. Each spectrograph module has three channels covering wavelength ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera. The cameras are very large, having a clear aperture of 300~mm at the entrance window, and a mass of ∌\sim280~kg. In this paper we describe the design of the visible camera cryostats and discuss various aspects of cryostat performance

    Fast All-Optical 10 Gb/s NRZ Wavelength Conversion and Power Limiting Function using Hybrid InP on SOI Nanocavity

    No full text
    International audienceA new optical switch is presented using InP/SOI hybrid photonic crystal nanocavity. Switching contrast of 11 dB with 20 mW peak power and recovery time of 14 ps are measured. NRZ wavelength conversion and power limiter are demonstrated at 10 Gb/s through system experiments with 6 and 1 mW peak power respectively

    Prime Focus Spectrograph - Subaru's future -

    Full text link
    The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 {\mu}m to 1.3 {\mu}m will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.Comment: 13 pages, 11 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)

    Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives

    Full text link
    PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.Comment: 17 pages, 10 figures. Proceeding of SPIE Astronomical Telescopes and Instrumentation 201

    Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru

    Full text link
    FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.Comment: 11 pages, 20 figure

    Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph

    Full text link
    The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.Comment: 14 pages, 12 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy V, Suzanne K. Ramsay, Ian S. McLean, Hideki Takami, Editors, Proc. SPIE 9147 (2014)

    Making space for shellfish farming along the Adriatic coast

    Get PDF
    This work focuses on the selection of new areas for shellfish farming along the coast of the Northern Adriatic Sea (Italy). Shellfish site suitability was assessed by means of a methodology based on Spatial Multi-Criteria Evaluation (SMCE), which provided the framework to combine mathematical models and operational oceanography products. Intermediate level criteria considered in the analysis included optimal growth conditions, environmental interactions, and socio-economic evaluation (e.g. organic carbon deposition; distance to harbour). Results showed that the whole coastal area comprised within 0 and 3 nm is highly suitable for farming of mussel, while the area comprised between 3 and 12 nm is divided between a highly suitable northern part, and a less suitable southern one. Seven different scenarios of development of shellfish aquaculture industry were explored. The introduction of a new species, and the assessment of the exposure to storm events are specific aspects taken into account in development scenarios. Results show that the degree of suitability for shellfish aquaculture in this area would not change dramatically with the introduction of oyster farming. Furthermore, results highlight that: (i) the growth potential in this area is high; (ii) the space with suitability index >0.5 increases when prioritizing the optimal growth condition criteria, and (iii) the socio-economic is the most restrictive Intermediate Level Criteria. Results were discussed by deriving general lessons concerning the use of SMCE in aquaculture space allocation, from the specific application in the Northern Adriatic Sea. Challenges and opportunities related to the proposed methodological framework, with particular reference to the use of resources provided by remote sensing and operational oceanography by means of mathematical models, were also discussed. Results can support a science-based identification of allocated zones for aquaculture in order to avoid conflicts, and promote sustainable aquaculture in the Mediterranean Sea, where the space for these activities is becoming increasingly limited

    Proteomic signatures of the oyster metabolic response to herpesvirus OsHV-1 ÎŒVar infection

    No full text
    International audiencePacific oyster Crassostrea gigas were inoculated with OsHV-1 at low load (control) or high load (challenged) to better understand the pathogenesis of ostreid herpesvirus 1 (OsHV-1 mu Var) and to determine which metabolic pathways might be affected during infection. Animals were sampled for proteomic analysis two days post-injection, at the same time as OsHV-1 initiated an intense replication phase in challenged oysters. Twenty-five abundant protein spots that showed a marked change in accumulated levels were identified using a two-dimensional electrophoresis (2-DE) proteomic approach. Overall, these proteins are involved in cytoskeleton organization, protein turnover, induction of stress signals, signalling pathways and energy metabolism. Challenged oysters exhibited an increased glycolysis and VDAC accumulation, which reflect a “Warburg effect” as initially reported in cancer cells and more recently in shrimp infected with virus. The results presented here should be useful for identifying potential biomarkers of disease resistance and developing antiviral measures. (C) 2014 Elsevier B.V. All rights reserved
    • 

    corecore