113 research outputs found

    Comparison of the sensitivity of a 24 h-shell vial assay, and conventional tube culture, in the isolation of Herpes simplex virus – 1 from corneal scrapings

    Get PDF
    BACKGROUND: Herpes simplex keratitis is a sight threatening ocular infection. A rapid and specific diagnosis is essential for the institution of specific antiviral therapy and to avoid complications that can arise from misdiagnosis and inappropriate treatment. Though a variety of techniques are available, isolation of Herpes simplex virus 1 (HSV-1) in culture provides the most reliable and specific method, and is considered as the gold standard in laboratory diagnosis of herpes simplex keratitis. We report a comparative study of the sensitivity of a 24 h-shell vial assay and conventional tube culture in the isolation of HSV-1 from corneal scrapings. METHODS: A total of 74 corneal scrapings obtained from 74 patients with a clinical suspicion of herpes simplex keratitis submitted for the isolation of HSV-1, were simultaneously inoculated into shell vial and tube cultures employing the vero cell line. Shell vial and tube cultures were terminated at 24 h and fifth day respectively. Isolation of HSV-1 was confirmed employing an indirect immunofluorescence assay. RESULTS: HSV-1 was isolated from 24/74 (32.4%) specimens employing both the methods. Sensitivity of both the techniques were found to be similar (20/24, 83.3%) (P = 1.0). CONCLUSION: A 24 h-shell vial assay is a rapid alternative technique in comparison to the time consuming conventional tube cultures for the isolation of HSV-1, especially from corneal scrapings for the laboratory diagnosis of herpes simplex keratitis

    Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis

    Get PDF
    BACKGROUND: Herpes simplex keratitis (HSK) is a sight threatening ocular infection often requiring a specific and prompt laboratory diagnosis. Isolation of Herpes simplex virus (HSV-1) in culture provides the most reliable and specific method and is considered as the "Gold Standard" in the laboratory diagnosis of HSK in spite of its low sensitivity. Using "cell lines of corneal origin" for virus isolation may be beneficial under such circumstances, since these cells have been shown to be excellent substrates for the growth of HSV-1 isolated from the cornea. We report a comparative study of a novel human corneal epithelial cell line (HCE) and the Vero cell line in the isolation of HSV-1 from corneal scrapings employing a shell vial assay. METHODS: Corneal scrapings were obtained from 17 patients with a clinical diagnosis of HSK. All the cases were confirmed by virological investigations (PCR and viral antigen detection positive, n = 15, PCR positive, n = 1, Viral antigen positive, n = 1). Scrapings obtained from 10 patients with infectious keratitis of non-viral origin were included as controls. All the scrapings were simultaneously inoculated into shell vials of HCE and Vero cells. Cultures were terminated at 24 h post-infection. Isolation of HSV-1 was confirmed using an indirect immunofluorescence/ immunoperoxidase assay. RESULTS: Virus could be isolated using both or either of the cell lines in 10/17 (58.82%) patients with HSK. HSV-1 was isolated from 10/ 17 (58.82%) and 4/17(23.52%) specimens in HCE and Vero cells, respectively (P = 0.036). None of the controls yielded HSV-1. While all the 10 (100%) strains were isolated in HCE, Vero yielded only 4/10 (40%) strains in the shell vial culture (P = 0.014). CONCLUSIONS: HCE showed a statistically significant difference in the virus isolation rate with respect to Vero cells. HCE may be an excellent alternative cell line for the isolation of HSV-1, especially from corneal scrapings, for the laboratory diagnosis of HSK

    Clinical utility of a nested nucleic acid amplification format in comparison to viral culture for the diagnosis of mucosal herpes simplex infection in a genitourinary medicine setting

    Get PDF
    BACKGROUND: Nested nucleic acid amplification tests are often thought too sensitive or prone to generatingfalse positive results for routine use. The current study investigated the specificity and clinicalutility of a routine multiplex nested assay for mucosal herpetic infections. METHODS: Ninety patients, categorised into those clinically diagnosed to (a) have and (b) not haveherpetic infection, were enrolled. Swabs from oral and ano-genital sites were assayed by thenested assay and culture and the results assessed against clinical evaluation for diagnosingherpetic infections; cell content was also recorded. RESULTS: Twenty-six and 64 patients were thought to (a) have and (b) not have mucosal herpeticinfection. Taking the clinical evaluation as indicating the presence of herpetic infection, thenested polymerase chain reaction and culture had respective sensitivities of 19/26 (73%) and12/26 (46%) (Χ(2) p = 0.02). There was no significant difference in specificities between nPCR62/64 (97%) and culture 63/64 (98%) (Χ(2) p = 1.0). Cell content was important for viraldetection by nPCR (Χ(2) p = 0.07) but not culture. Nesting was found necessary for sensitivity anddid not reduce specificity. Assay under-performance appeared related to sub-optimal cellcontent (20%) but may have reflected clinical over-diagnosis. The results suggest the need forvalidating specimen cell quality. CONCLUSIONS: This study questions the value of routine laboratory confirmation of mucosal herpetic infection. The adoption of a more discriminatory usage of laboratory diagnostic facilities for genital herpetic infection, taking account of cell content, and restricting it to those cases where it actually affects patient management, may be warranted

    Multiplex Detection and SNP Genotyping in a Single Fluorescence Channel

    Get PDF
    Probe-based PCR is widely used for SNP (single nucleotide polymorphism) genotyping and pathogen nucleic acid detection due to its simplicity, sensitivity and cost-effectiveness. However, the multiplex capability of hydrolysis probe-based PCR is normally limited to one target (pathogen or allele) per fluorescence channel. Current fluorescence PCR machines typically have 4–6 channels. We present a strategy permitting the multiplex detection of multiple targets in a single detection channel. The technique is named Multiplex Probe Amplification (MPA). Polymorphisms of the CYP2C9 gene (cytochrome P450, family 2, subfamily C, polypeptide 9, CYP2C9*2) and human papillomavirus sequences HPV16, 18, 31, 52 and 59 were chosen as model targets for testing MPA. The allele status of the CYP2C9*2 determined by MPA was entirely concordant with the reference TaqMan® SNP Genotyping Assays. The four HPV strain sequences could be independently detected in a single fluorescence detection channel. The results validate the multiplex capacity, the simplicity and accuracy of MPA for SNP genotyping and multiplex detection using different probes labeled with the same fluorophore. The technique offers a new way to multiplex in a single detection channel of a closed-tube PCR

    Comparison of three rapid and easy bacterial DNA extraction methods for use with quantitative real-time PCR

    Get PDF
    The development of fast and easy on-site molecular detection and quantification methods for hazardous microbes on solid surfaces is desirable for several applications where specialised laboratory facilities are absent. The quantification of bacterial contamination necessitates the assessment of the efficiency of the used methodology as a whole, including the preceding steps of sampling and sample processing. We used quantitative real-time polymerase chain reaction (qrtPCR) for Escherichia coli and Staphylococcus aureus to measure the recovery of DNA from defined numbers of bacterial cells that were subjected to three different DNA extraction methods: the QIAamp® DNA Mini Kit, Reischl et al.’s method and FTA® Elute. FTA® Elute significantly showed the highest median DNA extraction efficiency of 76.9% for E. coli and 108.9% for S. aureus. The Reischl et al. method and QIAamp® DNA Mini Kit inhibited the E. coli qrtPCR assay with a 10-fold decrease of detectable DNA. None of the methods inhibited the S. aureus qrtPCR assay. The FTA® Elute applicability was demonstrated with swab samples taken from the International Space Station (ISS) interior. Overall, the FTA® Elute method was found to be the most suitable to selected criteria in terms of rapidity, easiness of use, DNA extraction efficiency, toxicity, and transport and storage conditions

    Competitive Reporter Monitored Amplification (CMA) - Quantification of Molecular Targets by Real Time Monitoring of Competitive Reporter Hybridization

    Get PDF
    Background: State of the art molecular diagnostic tests are based on the sensitive detection and quantification of nucleic acids. However, currently established diagnostic tests are characterized by elaborate and expensive technical solutions hindering the development of simple, affordable and compact point-of-care molecular tests. Methodology and Principal Findings: The described competitive reporter monitored amplification allows the simultaneous amplification and quantification of multiple nucleic acid targets by polymerase chain reaction. Target quantification is accomplished by real-time detection of amplified nucleic acids utilizing a capture probe array and specific reporter probes. The reporter probes are fluorescently labeled oligonucleotides that are complementary to the respective capture probes on the array and to the respective sites of the target nucleic acids in solution. Capture probes and amplified target compete for reporter probes. Increasing amplicon concentration leads to decreased fluorescence signal at the respective capture probe position on the array which is measured after each cycle of amplification. In order to observe reporter probe hybridization in real-time without any additional washing steps, we have developed a mechanical fluorescence background displacement technique. Conclusions and Significance: The system presented in this paper enables simultaneous detection and quantification of multiple targets. Moreover, the presented fluorescence background displacement technique provides a generic solution fo

    Estimating Sensitivity of Laboratory Testing for Influenza in Canada through Modelling

    Get PDF
    Background: The weekly proportion of laboratory tests that are positive for influenza is used in public health surveillance systems to identify periods of influenza activity. We aimed to estimate the sensitivity of influenza testing in Canada based on results of a national respiratory virus surveillance system. Methods and Findings: The weekly number of influenza-negative tests from 1999 to 2006 was modelled as a function of laboratory-confirmed positive tests for influenza, respiratory syncytial virus (RSV), adenovirus and parainfluenza viruses, seasonality, and trend using Poisson regression. Sensitivity was calculated as the number of influenza positive tests divided by the number of influenza positive tests plus the model-estimated number of false negative tests. The sensitivity of influenza testing was estimated to be 33 % (95%CI 32–34%), varying from 30–40 % depending on the season and region. Conclusions: The estimated sensitivity of influenza tests reported to this national laboratory surveillance system is considerably less than reported test characteristics for most laboratory tests. A number of factors may explain this difference, including sample quality and specimen procurement issues as well as test characteristics. Improved diagnosis would permit better estimation of the burden of influenza

    Human T-lymphotropic virus type 1 (HTLV-1) prevalence and quantitative detection of DNA proviral load in individuals with indeterminate/positive serological results

    Get PDF
    BACKGROUND: HTLV-1 infection is currently restricted to endemic areas. To define the prevalence of HTLV-1 infection in patients living in Italy, we first carried out a retrospective serological analysis in a group of people originating from African countries referred to our hospital from January 2003 to February 2005. We subsequently applied a real time PCR on peripheral blood mononuclear cells from subjects with positive or indeterminate serological results. METHODS: All the sera were first analysed by serological methods (ELISA and/or Western Blotting) and then the peripheral blood mononuclear cells from subjects with positive or inconclusive serological results were analyzed for the presence of proviral DNA by a sensitive SYBR Green real time PCR. In addition, twenty HTLV-I ELISA negative samples were assayed by real time PCR approach as negative controls. RESULTS: Serological results disclosed serum reactivity by ELISA (absorbance values equal or greater than the cut-off value) in 9 out of 3408 individuals attending the Sexually Transmitted Diseases Clinic and/or Oncology Department, and 2 out 534 blood donors enrolled as a control population. Irrespective of positive or inconclusive serological results, all these subjects were analyzed for the presence of proviral DNA in peripheral blood mononuclear cells by SYBR real time PCR. A clear-cut positive result for the presence of HTLV-1 DNA was obtained in two subjects from endemic areas. CONCLUSION: SYBR real time PCR cut short inconclusive serological results. This rapid and inexpensive assay showed an excellent linear dynamic range, specificity and reproducibility readily revealing and quantifying the presence of virus in PBMCs. Our results highlight the need to monitor the presence of HTLV-1 in countries which have seen a large influx of immigrants in recent years. Epidemiological surveillance and correct diagnosis are recommended to verify the prevalence and incidence of a new undesirable phenomenon
    • …
    corecore