1,116 research outputs found
Outcomes of Cardiac Transplantation in Highly Sensitized Pediatric Patients
Despite aggressive immunosuppressive therapy, pediatric orthotopic heart transplant (OHT) candidates with elevated pre-transplant panel reactive antibody (PRA) carry an increased risk of rejection and early graft failure following transplantation. This study has aimed to more specifically evaluate the outcomes of transplant candidates stratified by PRA values. Records of pediatric patients listed for OHT between April 2004 and July 2008 were reviewed (n = 101). Survival analysis was performed comparing patients with PRA < 25 to those with PRA > 25, as well as patients with PRA < 80 and PRA > 80. Patients with PRA > 25 had decreased survival compared with those with PRA < 25 after listing (P = 0.004). There was an even greater difference in survival between patients with PRA > 80 and those with PRA < 80 (P = 0.002). Similar analyses for the patients who underwent successful transplantation showed no significant difference in post-transplant survival between patients with a pre-transplant PRA > 25 and those with PRA < 25 (P = 0.23). A difference approaching significance was noted for patients with PRA > 80 compared with PRA < 80 (P = 0.066). Patients with significantly elevated pre-transplant PRAs at the time of listing have a significantly worse outcome compared to those with moderately increased PRA values or non-sensitized patients. Further study is necessary to guide physician and family treatment decisions at the time of listing
Genomics of Divergence along a Continuum of Parapatric Population Differentiation
MM received funding from the Max Planck innovation funds for this project. PGDF was supported by a Marie Curie European Reintegration Grant (proposal nr 270891). CE was supported by German Science Foundation grants (DFG, EI 841/4-1 and EI 841/6-1)
Comparing mutation calls in fixed tumour samples between the Affymetrix OncoScan® Array and PCR based next-generation sequencing
Background: The importance of accurate and affordable mutation calling in fixed pathology samples is becoming increasingly important as we move into the era of personalised medicine. The Affymetrix OncoScan® Array platform is designed to produce actionable mutation calls in archival material. Methods: We compared calls made using the OncoScan platform with calls made using a custom designed PCR panel followed by next-generation sequencing (NGS), in order to benchmark the sensitivity and specificity of the OncoScan calls in a large cohort of fixed tumour samples. 392 fixed, clinical samples were sequenced, encompassing 641 PCR regions, 403 putative positive calls and 1528 putative negative calls. Results: A small number of mutations could not be validated, either due to large indels or pseudogenes impairing parts of the NGS pipeline. For the remainder, if calls were filtered according to simple quality metrics, both sensitivity and specificity for the OncoScan platform were over 98%. This applied even to samples with poorer sample quality and lower variant allele frequency (5–10%) than product claims indicated. Conclusions: This benchmarking study will be useful to users and potential users of this platform, who wish to compare technologies or interpret their own results
The experience of admission to psychiatric hospital among Chinese adult patients in Hong Kong
<p>Abstract</p> <p>Background</p> <p>The paper reports on a study to evaluate the psychometric properties and cultural appropriateness of the Chinese translation of the Admission Experience Survey (AES).</p> <p>Methods</p> <p>The AES was translated into Chinese and back-translated. Content validity was established by focus groups and expert panel review. The Chinese version of the Admission Experience Survey (C-AES) was administered to 135 consecutively recruited adult psychiatric patients in the Castle Peak Hospital (Hong Kong SAR, China) within 48 hours of admission. Construct validity was assessed by comparing the scores from patients admitted voluntarily versus patients committed involuntarily, and those received physical or chemical restraint versus those who did not. The relationship between admission experience and psychopathology was examined by correlating C-AES scores with the Brief Psychiatric Rating Scale (BPRS) scores.</p> <p>Results</p> <p>Spearman's item-to-total correlations of the C-AES ranged from 0.50 to 0.74. Three factors from the C-AES were extracted using factor analysis. Item 12 was omitted because of poor internal consistency and factor loading. The factor structure of the Process Exclusion Scale (C-PES) corresponded to the English version, while some discrepancies were noted in the Perceived Coercion Scale (C-PCS) and the Negative Pressure Scale (C-NPS). All subscales had good internal consistencies. Scores were significantly higher for patients either committed involuntarily or subjected to chemical or physical restrain, independent on severity of psychotic symptoms.</p> <p>Conclusion</p> <p>The Chinese AES is a psychometrically sound instrument assessing the three different aspects of the experience of admission, namely "negative pressure, "process exclusion" and "perceived coercion". The potential of C-AES in exploring subjective experience of psychiatric admission and effects on treatment adherence should be further explored.</p
Abnormal septal convexity into the left ventricle occurs in subclinical hypertrophic cardiomyopathy.
BACKGROUND: Sarcomeric gene mutations cause hypertrophic cardiomyopathy (HCM). In gene mutation carriers without left ventricular (LV) hypertrophy (G + LVH-), subclinical imaging biomarkers are recognized as predictors of overt HCM, consisting of anterior mitral valve leaflet elongation, myocardial crypts, hyperdynamic LV ejection fraction, and abnormal apical trabeculation. Reverse curvature of the interventricular septum (into the LV) is characteristic of overt HCM. We aimed to assess LV septal convexity in subclinical HCM. METHODS: Cardiovascular magnetic resonance was performed on 36 G + LVH- individuals (31 ± 14 years, 33 % males) with a pathogenic sarcomere mutation, and 36 sex and age-matched healthy controls (33 ± 12 years, 33 % males). Septal convexity (SCx) was measured in the apical four chamber view perpendicular to a reference line connecting the mid-septal wall at tricuspid valve insertion level and the apical right ventricular insertion point. RESULTS: Septal convexity was increased in G + LVH- compared to controls (maximal distance of endocardium to reference line: 5.0 ± 2.5 mm vs. 1.6 ± 2.4 mm, p ≤ 0.0001). Expected findings occurred in G + LVH- individuals: longer anterior mitral valve leaflet (23.5 ± 3.0 mm vs. 19.9 ± 3.1 mm, p ≤ 0.0001), higher relative wall thickness (0.31 ± 0.05 vs. 0.29 ± 0.04, p ≤ 0.05), higher LV ejection fraction (70.8 ± 4.3 % vs. 68.3 ± 4.4 %, p ≤ 0.05), and smaller LV end-systolic volume index (21.4 ± 4.4 ml/m(2) vs. 23.7 ± 5.8 ml/m(2), p ≤ 0.05). Other morphologic measurements (LV angles, sphericity index, and eccentricity index) were not different between G + LVH- and controls. CONCLUSIONS: Septal convexity is an additional previously undescribed feature of subclinical HCM
A Measurement of Rb using a Double Tagging Method
The fraction of Z to bbbar events in hadronic Z decays has been measured by
the OPAL experiment using the data collected at LEP between 1992 and 1995. The
Z to bbbar decays were tagged using displaced secondary vertices, and high
momentum electrons and muons. Systematic uncertainties were reduced by
measuring the b-tagging efficiency using a double tagging technique. Efficiency
correlations between opposite hemispheres of an event are small, and are well
understood through comparisons between real and simulated data samples. A value
of Rb = 0.2178 +- 0.0011 +- 0.0013 was obtained, where the first error is
statistical and the second systematic. The uncertainty on Rc, the fraction of Z
to ccbar events in hadronic Z decays, is not included in the errors. The
dependence on Rc is Delta(Rb)/Rb = -0.056*Delta(Rc)/Rc where Delta(Rc) is the
deviation of Rc from the value 0.172 predicted by the Standard Model. The
result for Rb agrees with the value of 0.2155 +- 0.0003 predicted by the
Standard Model.Comment: 42 pages, LaTeX, 14 eps figures included, submitted to European
Physical Journal
Using a virtual environment to assess cognition in the elderly
YesEarly diagnosis of Alzheimer’s disease (AD) is essential if treatments are to be administered at an earlier point in time before neurons degenerate to a stage beyond repair. In order for early detection to occur tools used to detect the disorder must be sensitive to the earliest of cognitive impairments. Virtual reality (VR) technology offers opportunities to provide products which attempt to mimic daily life situations, as much as is possible, within the computational environment. This may be useful for the detection of cognitive difficulties. We develop a virtual simulation designed to assess visuospatial memory in order to investigate cognitive function in a group of healthy elderly participants and those with a mild cognitive impairment. Participants were required to guide themselves along a virtual path to reach a virtual destination which they were required to remember. The preliminary results indicate that this virtual simulation has the potential to be used for detection of early AD since significant correlations of scores on the virtual environment with existing neuropsychological tests were found. Furthermore, the test discriminated between healthy elderly participants and those with a mild cognitive impairment (MCI)
Measurement of the B+ and B-0 lifetimes and search for CP(T) violation using reconstructed secondary vertices
The lifetimes of the B+ and B-0 mesons, and their ratio, have been measured in the OPAL experiment using 2.4 million hadronic Z(0) decays recorded at LEP. Z(0) --> b (b) over bar decays were tagged using displaced secondary vertices and high momentum electrons and muons. The lifetimes were then measured using well-reconstructed charged and neutral secondary vertices selected in this tagged data sample. The results aretau(B+) = 1.643 +/- 0.037 +/- 0.025 pstau(Bo) = 1.523 +/- 0.057 +/- 0.053 pstau(B+)/tau(Bo) = 1.079 +/- 0.064 +/- 0.041,where in each case the first error is statistical and the second systematic.A larger data sample of 3.1 million hadronic Z(o) decays has been used to search for CP and CPT violating effects by comparison of inclusive b and (b) over bar hadron decays, No evidence fur such effects is seen. The CP violation parameter Re(epsilon(B)) is measured to be Re(epsilon(B)) = 0.001 +/- 0.014 +/- 0.003and the fractional difference between b and (b) over bar hadron lifetimes is measured to(Delta tau/tau)(b) = tau(b hadron) - tau((b) over bar hadron)/tau(average) = -0.001 +/- 0.012 +/- 0.008
- …