4,144 research outputs found

    Laser spectroscopy of the C1Σ+-X1Σ+ transition of ScBr

    Get PDF
    The laser induced fluorescence spectrum of scandium monobromide (ScBr) between 795 and 845 nm has been recorded and analyzed. ScBr was produced by reacting laser vaporized Sc atoms with ethyl bromide (C 2H 5Br). Spectra of six vibrational bands of both Sc 79Br and Sc 81Br isotopomers of the C 1Σ +-X 1Σ + transition were observed. A least-squares fit of the measured line positions yielded accurate molecular constants for the v = 0-3 levels of the C 1Σ + state and the v = 0-2 levels of the X 1Σ + state. The equilibrium bond length of the C 1Σ + state has been determined to be 2.4776 . © 2012 Elsevier B.V. All rights reserved.postprin

    Laser Induced Fluorescence Spectroscopy Of Scandium Monoiodide

    Get PDF
    Oral PresentationSession: RA ElectronicThe laser induced fluorescence spectrum of scandium monoiodide (ScI) between 787 and 814 nm has been recorded. ScI molecule was produced by reacting laser vaporized Sc atoms with methyl iodide (CH3I). Spectra of eleven vibrational bands of the C1Σ + - X1Σ + transition of ScI were obtained and analyzed. A merged least-squares fit of the measured line positions yielded accurate molecular constants for the upper levels of the C1Σ + state and the v = 1 - 4 levels of the X1Σ +state. One vibrational band observed at 11627 cm−1 belongs to a sub-band transition of the a3∆ state, which is found to be perturbed by the X1Σ + state. Details of the perturbation and molecular constants obtained will be reported.published_or_final_versio

    Diffusion and growth of metal clusters in nanocomposites: a Kinetic Monte Carlo study

    Full text link
    Nobel metals that are deposited on a polymer surface exhibit surface diffusion and diffusion into the bulk. At the same time the metal atoms tend to form clusters because their cohesive energy is about two orders of magnitude higher than the cohesive energy of polymers. To selfconsistently simulate these coupled processes, we present in this paper a Kinetic Monte Carlo approach. Using a simple model with diffusion coefficients taken as input parameters allows us to perform a systematic study of the behavior of a large ensemble of metal atoms on a polymer surface eventually leading to polymer nanocomposites. Special emphasis is placed on the cluster growth, cluster size distribution and the penetration of clusters into the substrate. We also study the influence of surface defects and analyze how the properties of the resulting material can be controlled by variation of the deposition rate

    EZH2 protein: A promising immunomarker for the detection of hepatocellular carcinomas in liver needle biopsies

    Get PDF
    Background and aims: A previous study of ours indicated that enhancer of zeste homologue 2 (EZH2) plays an important role in hepatocellular carcinoma (HCC) tumorigenesis. The aim of the present study was to investigate the potential diagnostic utility of EZH2 in HCC. Methods: Immunohistochemistry was performed to examine the expression dynamics of EZH2 in two independent surgical cohorts of HCC and non-malignant liver tissues to develop a diagnostic yield of EZH2, HSP70 and GPC3 for HCC detection. The diagnostic performances of EZH2 and a three-marker panel in HCC were re-evaluated by using an additional biopsy cohort. Results: Immunohistochemistry analysis demonstrated that the sensitivity and specificity of EZH2 for HCC detection was 95.8% and 97.8% in the testing cohort. Similar results were confirmed in the validation cohort. For diagnosis of well-differentiated HCCs, the sensitivity and specificity were 68.9% and 91.5% for EZH2, 62.5% and 98.5% for HSP70, 50.0% and 92.1% for GPC3, and 75.0% and 100% for a three-marker panel. In biopsies, positive cases for at least one marker increased from large regenerative nodule and hepatocellular adenoma (0/12) to focal nodular hyperplasia (2/20), dysplastic nodule (7/25), well-differentiated HCC (16/18) and moderately and poorly differentiated HCC (54/54). When at least two positive markers were considered, regardless of their identity, the positive cases were detected in 0/12 large regenerative nodules and hepatocellular adenomas, 0/20 focal nodular hyperplasias, 0/25 dysplastic nodules, 11/18 well-differentiated HCCs, 32/37 moderately differentiated HCCs and 15/17 poorly differentiated HCCs. Conclusion: Our findings suggest that EZH2 protein, as examined by immunohistochemistry, may serve as a promising diagnostic biomarker of HCCs, and the use of a three-marker panel (EZH2, HSP70 and GPC3) can improve the rate of detection of HCCs in liver biopsy tissues.published_or_final_versio

    Optimising use of electronic health records to describe the presentation of rheumatoid arthritis in primary care: a strategy for developing code lists

    Get PDF
    Background Research using electronic health records (EHRs) relies heavily on coded clinical data. Due to variation in coding practices, it can be difficult to aggregate the codes for a condition in order to define cases. This paper describes a methodology to develop ‘indicator markers’ found in patients with early rheumatoid arthritis (RA); these are a broader range of codes which may allow a probabilistic case definition to use in cases where no diagnostic code is yet recorded. Methods We examined EHRs of 5,843 patients in the General Practice Research Database, aged ≥30y, with a first coded diagnosis of RA between 2005 and 2008. Lists of indicator markers for RA were developed initially by panels of clinicians drawing up code-lists and then modified based on scrutiny of available data. The prevalence of indicator markers, and their temporal relationship to RA codes, was examined in patients from 3y before to 14d after recorded RA diagnosis. Findings Indicator markers were common throughout EHRs of RA patients, with 83.5% having 2 or more markers. 34% of patients received a disease-specific prescription before RA was coded; 42% had a referral to rheumatology, and 63% had a test for rheumatoid factor. 65% had at least one joint symptom or sign recorded and in 44% this was at least 6-months before recorded RA diagnosis. Conclusion Indicator markers of RA may be valuable for case definition in cases which do not yet have a diagnostic code. The clinical diagnosis of RA is likely to occur some months before it is coded, shown by markers frequently occurring ≥6 months before recorded diagnosis. It is difficult to differentiate delay in diagnosis from delay in recording. Information concealed in free text may be required for the accurate identification of patients and to assess the quality of care in general practice

    Minimal models with light sterile neutrinos

    Get PDF
    We study the constraints imposed by neutrino oscillation experiments on the minimal extensions of the Standard Model (SM) with nRn_R gauge singlet fermions ("right-handed neutrinos"), that can account for neutrino masses. We consider the most general coupling to SM fields of the new fields, in particular those that break lepton number and we do not assume any a priori hierarchy in the mass parameters. We proceed to analyze these models starting from the lowest level of complexity, defined by the number of extra fermionic degrees of freedom. The simplest choice that has enough free parameters in principle (i.e. two mass differences and two angles) to explain the confirmed solar and atmospheric oscillations corresponds to nR=1n_R=1. This minimal choice is shown to be excluded by data. The next-to-minimal choice corresponds to nR=2n_R=2. We perform a systematic study of the full parameter space in the limit of degenerate Majorana masses by requiring that at least two neutrino mass differences correspond to those established by solar and atmospheric oscillations. We identify several types of spectra that can fit long-baseline reactor and accelerator neutrino oscillation data, but fail in explaining solar and/or atmospheric data. The only two solutions that survive are the expected seesaw and quasi-Dirac regions, for which we set lower and upper bounds respectively on the Majorana mass scale. Solar data from neutral current measurements provide essential information to constrain the quasi-Dirac region. The possibility to accommodate the LSND/MiniBoone and reactor anomalies, and the implications for neutrinoless double-beta decay and tritium beta decay are briefly discussed.Comment: 32 pages, 15 figures. Misprints and a small error corrected, references added. Conclusions unchange

    Simulations of events for the LUX-ZEPLIN (LZ) dark matter experiment

    Get PDF
    The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1–2)×10−12 pb at a WIMP mass of 40 GeV/c2. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data
    • …
    corecore