253 research outputs found

    Osmium isotope evidence for two pulses of increased continental weathering linked to Early Jurassic volcanism and climate change

    Get PDF
    Large igneous provinces (LIPs) are proposed to have caused a number of episodes of abrupt environmental change by increasing atmospheric CO2 levels, which were subsequently alleviated by drawdown of CO2 via enhanced continental weathering and burial of organic matter. Here the sedimentary records of two such episodes of environmental change, the Toarcian oceanic anoxic event (T-OAE) and preceding Pliensbachian–Toarcian (Pl-To) event (both possibly linked to the Karoo-Ferrar LIP), are investigated using a new suite of geochemical proxies that have not been previously compared. Stratigraphic variations in osmium isotope (187Os/188Os) records are compared with those of mercury (Hg) and carbon isotopes (d13C) in samples from the Mochras core, Llanbedr Farm, Cardigan Bay Basin, Wales. These sedimentary rocks are confirmed as recording an open-marine setting by analysis of molybdenum/uranium enrichment trends, indicating that the Os isotope record in these samples reflects the isotopic composition of the global ocean. The Os isotope data include the first results across the Pl-To boundary, when seawater 187Os/188Os increased from ~0.40 to ~0.53, in addition to new data that show elevated 187Os/188Os (from ~0.42 to ~0.68) during the T-OAE. Both increases in 187Os/188Os correlate with negative carbon isotope excursions and increased mercury concentrations, supporting an interplay between terrestrial volcanism, weathering, and climate that was instrumental in driving these distinct episodes of global environmental change. These observations also indicate that the environmental impact of the Karoo-Ferrar LIP was not limited solely to the T-OAE

    Emergency hospital care for adults with suspected seizures in the NHS in England 2007-2013: a cross-sectional study

    Get PDF
    Aims To quantify the frequency, characteristics, geographical variation and costs of emergency hospital care for suspected seizures. Design Cross-sectional study using routinely collected data (Hospital Episode Statistics). Setting The National Health Service in England 2007–2013. Participants Adults who attended an emergency department (ED) or were admitted to hospital. Results In England (population 2011: 53.11 million, 41.77 million adults), suspected seizures gave rise to 50 111 unscheduled admissions per year among adults (≥18 years). This is 47.1% of unscheduled admissions for neurological conditions and 0.71% of all unscheduled admissions. Only a small proportion of admissions for suspected seizures were coded as status epilepticus (3.5%) and there were a very small number of dissociative (non-epileptic) seizures. The median length of stay for each admission was 1 day, the median cost for each admission was £1651 (2175)andthetotalcostofalladmissionsforsuspectedseizuresinEnglandwas£88.2million(2175) and the total cost of all admissions for suspected seizures in England was £88.2 million (116.2 million) per year. 16.8% of patients had more than one admission per year. There was significant geographical variability in the rate of admissions corrected for population age and gender differences and some areas had rates of admission which were consistently higher than the average. Conclusions Our data show that suspected seizures are the most common neurological cause of admissions to hospital in England, that readmissions are common and that there is significant geographical variability in admission rates. This variability has not previously been reported in the published literature. The cause of the geographical variation is unknown; important factors are likely to include prevalence, deprivation and clinical practice and these require further investigation. Dissociative seizures are not adequately diagnosed during ED attendances and hospital admissions

    Measurement of the Nucleon Structure Function F2 in the Nuclear Medium and Evaluation of its Moments

    Full text link
    We report on the measurement of inclusive electron scattering off a carbon target performed with CLAS at Jefferson Laboratory. A combination of three different beam energies 1.161, 2.261 and 4.461 GeV allowed us to reach an invariant mass of the final-state hadronic system W~2.4 GeV with four-momentum transfers Q2 ranging from 0.2 to 5 GeV2. These data, together with previous measurements of the inclusive electron scattering off proton and deuteron, which cover a similar continuous two-dimensional region of Q2 and Bjorken variable x, permit the study of nuclear modifications of the nucleon structure. By using these, as well as other world data, we evaluated the F2 structure function and its moments. Using an OPE-based twist expansion, we studied the Q2-evolution of the moments, obtaining a separation of the leading-twist and the total higher-twist terms. The carbon-to-deuteron ratio of the leading-twist contributions to the F2 moments exhibits the well known EMC effect, compatible with that discovered previously in x-space. The total higher-twist term in the carbon nucleus appears, although with large systematic uncertainites, to be smaller with respect to the deuteron case for n<7, suggesting partial parton deconfinement in nuclear matter. We speculate that the spatial extension of the nucleon is changed when it is immersed in the nuclear medium.Comment: 37 pages, 15 figure

    Precise Measurements of Beam Spin Asymmetries in Semi-Inclusive π0\pi^0 production

    Get PDF
    We present studies of single-spin asymmetries for neutral pion electroproduction in semi-inclusive deep-inelastic scattering of 5.776 GeV polarized electrons from an unpolarized hydrogen target, using the CEBAF Large Acceptance Spectrometer (CLAS) at the Thomas Jefferson National Accelerator Facility. A substantial sinϕh\sin \phi_h amplitude has been measured in the distribution of the cross section asymmetry as a function of the azimuthal angle ϕh\phi_h of the produced neutral pion. The dependence of this amplitude on Bjorken xx and on the pion transverse momentum is extracted with significantly higher precision than previous data and is compared to model calculations.Comment: to be submitted PL

    First measurement of direct f0(980)f_0(980) photoproduction on the proton

    Get PDF
    We report on the results of the first measurement of exclusive f0(980)f_0(980) meson photoproduction on protons for Eγ=3.03.8E_\gamma=3.0 - 3.8 GeV and t=0.41.0-t = 0.4-1.0 GeV2^2. Data were collected with the CLAS detector at the Thomas Jefferson National Accelerator Facility. The resonance was detected via its decay in the π+π\pi^+ \pi^- channel by performing a partial wave analysis of the reaction γppπ+π\gamma p \to p \pi^+ \pi^-. Clear evidence of the f0(980)f_0(980) meson was found in the interference between PP and SS waves at Mπ+π1M_{\pi^+ \pi^-}\sim 1 GeV. The SS-wave differential cross section integrated in the mass range of the f0(980)f_0(980) was found to be a factor of 50 smaller than the cross section for the ρ\rho meson. This is the first time the f0(980)f_0(980) meson has been measured in a photoproduction experiment

    Prehospital early warning scores for adults with suspected sepsis: retrospective diagnostic cohort study

    Get PDF
    Background Ambulance services need to identify and prioritise patients with sepsis for early hospital assessment. We aimed to determine the accuracy of early warning scores alongside paramedic diagnostic impression to identify sepsis that required urgent treatment. Methods We undertook a retrospective diagnostic cohort study involving adult emergency medical cases transported to Sheffield Teaching Hospitals ED by Yorkshire Ambulance Service in 2019. We used routine ambulance service data to calculate 21 early warning scores and categorise paramedic diagnostic impressions as sepsis, infection, non-specific presentation or other presentation. We linked cases to hospital records and identified those meeting the sepsis-3 definition who received urgent hospital treatment for sepsis (reference standard). Analysis determined the accuracy of strategies that combined early warning scores at varying thresholds for positivity with paramedic diagnostic impression. Results We linked 12 870/24 955 (51.6%) cases and identified 348/12 870 (2.7%) with a positive reference standard. None of the strategies provided sensitivity greater than 0.80 with positive predictive value greater than 0.15. The area under the receiver operating characteristic curve for the National Early Warning Score, version 2 (NEWS2) applied to patients with a diagnostic impression of sepsis or infection was 0.756 (95% CI 0.729, 0.783). No other early warning score provided clearly superior accuracy to NEWS2. Paramedic impression of sepsis or infection had sensitivity of 0.572 (0.519, 0.623) and positive predictive value of 0.156 (0.137, 0.176). NEWS2 thresholds of >4, >6 and >8 applied to patients with a diagnostic impression of sepsis or infection, respectively, provided sensitivities and positive predictive values of 0.522 (0.469, 0.574) and 0.216 (0.189, 0.245), 0.447 (0.395, 0.499) and 0.274 (0.239, 0.313), and 0.314 (0.268, 0.365) and 0.333 (0.284, 0.386). Conclusion No strategy is ideal but using NEWS2 alongside paramedic diagnostic impression of infection or sepsis could identify one-third to half of sepsis cases without prioritising unmanageable numbers. No other score provided clearly superior accuracy to NEWS2

    Prehospital early warning scores for adults with suspected sepsis: the PHEWS observational cohort and decision-analytic modelling study

    Get PDF
    Background Guidelines for sepsis recommend treating those at highest risk within 1 hour. The emergency care system can only achieve this if sepsis is recognised and prioritised. Ambulance services can use prehospital early warning scores alongside paramedic diagnostic impression to prioritise patients for treatment or early assessment in the emergency department. Objectives To determine the accuracy, impact and cost-effectiveness of using early warning scores alongside paramedic diagnostic impression to identify sepsis requiring urgent treatment. Design Retrospective diagnostic cohort study and decision-analytic modelling of operational consequences and cost-effectiveness. Setting Two ambulance services and four acute hospitals in England. Participants Adults transported to hospital by emergency ambulance, excluding episodes with injury, mental health problems, cardiac arrest, direct transfer to specialist services, or no vital signs recorded. Interventions Twenty-one early warning scores used alongside paramedic diagnostic impression, categorised as sepsis, infection, non-specific presentation, or other specific presentation. Main outcome measures Proportion of cases prioritised at the four hospitals; diagnostic accuracy for the sepsis-3 definition of sepsis and receiving urgent treatment (primary reference standard); daily number of cases with and without sepsis prioritised at a large and a small hospital; the minimum treatment effect associated with prioritisation at which each strategy would be cost-effective, compared to no prioritisation, assuming willingness to pay £20,000 per quality-adjusted life-year gained. Results Data from 95,022 episodes involving 71,204 patients across four hospitals showed that most early warning scores operating at their pre-specified thresholds would prioritise more than 10% of cases when applied to non-specific attendances or all attendances. Data from 12,870 episodes at one hospital identified 348 (2.7%) with the primary reference standard. The National Early Warning Score, version 2 (NEWS2), had the highest area under the receiver operating characteristic curve when applied only to patients with a paramedic diagnostic impression of sepsis or infection (0.756, 95% confidence interval 0.729 to 0.783) or sepsis alone (0.655, 95% confidence interval 0.63 to 0.68). None of the strategies provided high sensitivity (> 0.8) with acceptable positive predictive value (> 0.15). NEWS2 provided combinations of sensitivity and specificity that were similar or superior to all other early warning scores. Applying NEWS2 to paramedic diagnostic impression of sepsis or infection with thresholds of > 4, > 6 and > 8 respectively provided sensitivities and positive predictive values (95% confidence interval) of 0.522 (0.469 to 0.574) and 0.216 (0.189 to 0.245), 0.447 (0.395 to 0.499) and 0.274 (0.239 to 0.313), and 0.314 (0.268 to 0.365) and 0.333 (confidence interval 0.284 to 0.386). The mortality relative risk reduction from prioritisation at which each strategy would be cost-effective exceeded 0.975 for all strategies analysed. Limitations We estimated accuracy using a sample of older patients at one hospital. Reliable evidence was not available to estimate the effectiveness of prioritisation in the decision-analytic modelling. Conclusions No strategy is ideal but using NEWS2, in patients with a paramedic diagnostic impression of infection or sepsis could identify one-third to half of sepsis cases without prioritising unmanageable numbers. No other score provided clearly superior accuracy to NEWS2. Research is needed to develop better definition, diagnosis and treatments for sepsis. Study registration This study is registered as Research Registry (reference: researchregistry5268). Funding This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 17/136/10) and is published in full in Health Technology Assessment; Vol. 28, No. 16. See the NIHR Funding and Awards website for further award information

    The epitaxy of gold

    Full text link
    corecore