586 research outputs found

    Spatiotemporal Dynamics of Genetic Variation in the Iberian Lynx along Its Path to Extinction Reconstructed with Ancient DNA

    Get PDF
    There is the tendency to assume that endangered species have been both genetically and demographically healthier in the past, so that any genetic erosion observed today was caused by their recent decline. The Iberian lynx (Lynx pardinus) suffered a dramatic and continuous decline during the 20th century, and now shows extremely low genome- and specieswide genetic diversity among other signs of genomic erosion. We analyze ancient (N¼10), historical (N¼245), and contemporary (N¼172) samples with microsatellite and mitogenome data to reconstruct the species’ demography and investigate patterns of genetic variation across space and time. Iberian lynx populations transitioned from low but significantly higher genetic diversity than today and shallow geographical differentiation millennia ago, through a structured metapopulation with varying levels of diversity during the last centuries, to two extremely genetically depauperate and differentiated remnant populations by 2002. The historical subpopulations show varying extents of genetic drift in relation to their recent size and time in isolation, but these do not predict whether the populations persisted or went finally extinct. In conclusion, current genetic patterns were mainly shaped by genetic drift, supporting the current admixture of the two genetic pools and calling for a comprehensive genetic management of the ongoing conservation program. This study illustrates how a retrospective analysis of demographic and genetic patterns of endangered species can shed light onto their evolutionary history and this, in turn, can inform conservation actions

    European Association of Cardiothoracic Anesthesiology and Intensive Care (EACTAIC) Fellowship Curriculum: Second Edition.

    Get PDF
    International audienceThis document represents the first update of the Cardiothoracic and Vascular Anaesthesia Fellowship Curriculum of the European Association of Cardiothoracic Anaesthesiology and Intensive Care. After obtaining feedback from exit interviews with fellows in training, graduate fellows, and program directors, 2 modified online Delphi procedures with questionnaires were conducted. A consensus was reached when two-thirds of responding committee members gave green or yellow ratings on a traffic light system, and >70% indicated strong agreement or agreement on a 5-point Likert scale. The new regulations include the following: (1) more flexibility in the fellows` rotation, as long as the total number of days, rotations, and cases are completed during the training year; (2) recommendation for strict compliance with national working-time guidelines; (3) no extension of fellowship training to compensate for annual and/or sick leave, unless the required minimum number of cases and rotations are not reached; (4) interruption of fellowship training for >12 months is allowed for personal or medical reasons; (5) introduction of a checklist for quantitative assessment of standard clinical skills; (6) recommendations for a uniform structure of exit interviews; (7) possibility of a 1-month training rotation in a postanesthesia care unit instead of an intensive care unit; and (8) provided all other requirements have been met, the allowance of progression from the basic training year to the advanced fellowship training year without first passing the transesophageal echocardiography examination

    The NEXT White (NEW) detector

    Get PDF
    Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for Xe-136 beta beta 0 nu decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation

    Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

    Get PDF
    We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in similar to 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +/- 0.13 mm-sigma (longitudinal), 0.95 +/- 0.20 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8 mm x 8 mm x 1.2 mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (epsilon) at full width half maximum (R) inside the fiducial volume ranged from R = 14.6% (30 keV) to R = 4.6% (1.275 MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (beta beta 0 nu) in Xe-136, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R =1.4%root MeV/epsilon levels obtained in small sensors are discussedThe NEXT collaboration acknowledges funding support from the following agencies and institutions: European Research Council under Advanced Grant 339787-NEXT and Starting Grant 240054-TREX, Spanish Ministerio de Economia y Competitividad under grants Consolider-Ingenio 2010 CSD2008-0037 (CUP) and CSD2007-00042 (CPAN), contracts FPA2008-03456 and FPA2009-13697; Portuguese Fundacao para a Ciencia e a Tecnologia; European FEDER under grant PPTDC/FIS/103860/2008; US Department Of Energy under contract DE-AC02-05CH11231.Gonzalez Diaz, D.; Álvarez Puerta, V.; Borges, FIG.; Camargo, M.; Carcel, S.; Cebrian, S.; Cervera, A.... (2015). Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 804:8-24. https://doi.org/10.1016/j.nima.2015.08.033S82480

    Relationship between olive oil consumption and ankle-brachial pressure index in a population at high cardiovascular risk

    Get PDF
    The aim of this study was to ascertain the association between the consumption of different categories of edible olive oils (virgin olive oils and olive oil) and olive pomace oil and ankle-brachial pressure index (ABI) in participants in the PREDIMED-Plus study, a trial of lifestyle modification for weight and cardiovascular event reduction in individuals with overweight/obesity harboring the metabolic syndrome. Methods: We performed a cross-sectional analysis of the PREDIMED-Plus trial. Consumption of any category of olive oil and olive pomace oil was assessed through a validated food-frequency questionnaire. Multivariable linear regression models were fitted to assess associations between olive oil consumption and ABI. Additionally, ABI ≤1 was considered as the outcome in logistic models with different categories of olive oil and olive pomace oil as exposure. Results: Among 4330 participants, the highest quintile of total olive oil consumption (sum of all categories of olive oil and olive pomace oil) was associated with higher mean values of ABI (beta coefficient: 0.014, 95% confidence interval [CI]: 0.002, 0.027) (p for trend = 0.010). Logistic models comparing the consumption of different categories of olive oils, olive pomace oil and ABI ≤1 values revealed an inverse association between virgin olive oils consumption and the likelihood of a low ABI (odds ratio [OR] 0.73, 95% CI [0.56, 0.97]), while consumption of olive pomace oil was positively associated with a low ABI (OR 1.22 95% CI [1.00, 1.48]). Conclusions: In a Mediterranean population at high cardiovascular risk, total olive oil consumption was associated with a higher mean ABI. These results suggest that olive oil consumption may be beneficial for peripheral artery disease prevention, but longitudinal studies are needed
    corecore