103 research outputs found
Symmetry Detection in Large Scale City Scans
In this report we present a novel method for detecting partial symmetries in very large point clouds of 3D city scans. Unlike previous work, which was limited to data sets of a few hundred megabytes maximum, our method scales to very large scenes. We map the detection problem to a nearestneighbor search in a low-dimensional feature space, followed by a cascade of tests for geometric clustering of potential matches. Our algorithm robustly handles noisy real-world scanner data, obtaining a recognition performance comparable to state-of-the-art methods. In practice, it scales linearly with the scene size and achieves a high absolute throughput, processing half a terabyte of raw scanner data over night on a dual socket commodity PC
Generalized intrinsic symmetry detection
In this paper, we address the problem of detecting partial symmetries in 3D objects. In contrast to previous work, our algorithm is able to match deformed symmetric parts: We first develop an algorithm for the case of approximately isometric deformations, based on matching graphs of surface feature lines that are annotated with intrinsic geometric properties. The sensitivity to non-isometry is controlled by tolerance parameters for each such annotation. Using large tolerance values for some of these annotations and a robust matching of the graph topology yields a more general symmetry detection algorithm that can detect similarities in structures that have undergone strong deformations. This approach for the first time allows for detecting partial intrinsic as well as more general, non-isometric symmetries. We evaluate the recognition performance of our technique for a number synthetic and real-world scanner data sets
Dark Matter Results from 100 Live Days of XENON100 Data
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.Comment: 5 pages, 5 figures; matches accepted versio
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.Comment: 3 pages, 3 figure
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.Comment: 3 pages, no figure
Material screening and selection for XENON100
Results of the extensive radioactivity screening campaign to identify
materials for the construction of XENON100 are reported. This Dark Matter
search experiment is operated underground at Laboratori Nazionali del Gran
Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors
(HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been
applied for a few low mass plastic samples. Detailed tables with the
radioactive contaminations of all screened samples are presented, together with
the implications for XENON100.Comment: 8 pages, 1 figur
Recommended from our members
Improved Upper Limit on the Neutrino Mass from a Direct Kinematic Method by KATRIN.
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic end point at 18.57 keV gives an effective neutrino mass square value of (-1.0_{-1.1}^{+0.9})  eV^{2}. From this, we derive an upper limit of 1.1 eV (90% confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of 2 and provides model-independent input to cosmological studies of structure formation
Commissioning of the vacuum system of the KATRIN Main Spectrometer
The KATRIN experiment will probe the neutrino mass by measuring the
beta-electron energy spectrum near the endpoint of tritium beta-decay. An
integral energy analysis will be performed by an electro-static spectrometer
(Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a
volume of 1240 m^3, and a complex inner electrode system with about 120000
individual parts. The strong magnetic field that guides the beta-electrons is
provided by super-conducting solenoids at both ends of the spectrometer. Its
influence on turbo-molecular pumps and vacuum gauges had to be considered. A
system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter
strips has been deployed and was tested during the commissioning of the
spectrometer. In this paper the configuration, the commissioning with bake-out
at 300{\deg}C, and the performance of this system are presented in detail. The
vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is
demonstrated that the performance of the system is already close to these
stringent functional requirements for the KATRIN experiment, which will start
at the end of 2016.Comment: submitted for publication in JINST, 39 pages, 15 figure
Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project
The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source
for a liquid noble gas dark matter experiment like the XENON project. However,
the risk of contamination of the detector with traces of the much longer lived
mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the
release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has
been investigated. To do so, a cryogenic trap has been connected to the source
for about 10 days, after which it was removed and probed for the strongest 83Rb
gamma-rays with an ultra-sensitive Germanium detector. No signal has been
found. The corresponding upper limit on the released 83Rb activity means that
the investigated type of source can be used in the XENON project and similar
low-background experiments as 83mKr generator without a significant risk of
contaminating the detector. The measurements also allow to set upper limits on
the possible release of the isotopes 84Rb and 86Rb, traces of which were
created alongside the production of 83Rb at the Rez cyclotron.Comment: 11 pages, 7 figures, submitted to Journal of Instrumentatio
- …