732 research outputs found

    Introducing our new series:Clinical & experimental treatment of

    Get PDF

    Isotype selection for antibody-based cancer therapy

    Get PDF
    The clinical application of monoclonal antibodies (mAbs) has revolutionized the field of cancer therapy, as it has enabled the successful treatment of previously untreatable types of cancer. Different mechanisms play a role in the anti‐tumour effect of mAbs. These include blocking of tumour‐specific growth factor receptors or of immune modulatory molecules as well as complement and cell‐mediated tumour cell lysis. Thus, for many mAbs, Fc‐mediated effector functions critically contribute to the efficacy of treatment. As immunoglobulin (Ig) isotypes differ in their ability to bind to Fc receptors on immune cells as well as in their ability to activate complement, they differ in the immune responses they activate. Therefore, the choice of antibody isotype for therapeutic mAbs is dictated by its intended mechanism of action. Considering that clinical efficacy of many mAbs is currently achieved only in subsets of patients, optimal isotype selection and Fc optimization during antibody development may represent an important step towards improved patient outcome. Here, we discuss the current knowledge of the therapeutic effector functions of different isotypes and Fc‐engineering strategies to improve mAbs application

    The proteasome inhibitor PI31 competes with PA28 for binding to 20S proteasomes

    Get PDF
    AbstractPI31 is a previously described inhibitor of 20S proteasomes. Using recombinant PI31 we have analyzed its effect on proteasomal hydrolyzing activity of short fluorogenic substrates and of a synthetic 40-mer polypeptide. In addition, we investigated its influence on the activation of 20S proteasome by the proteasome activator PA28. PI31 inhibits polypeptide degradation already at concentrations which only partially inhibit fluorogenic substrate turnover and immunosubunits do not influence the PI31 binding affinity. Furthermore our data demonstrate that PI31 is a potent competitor of PA28-mediated activation

    In a therapeutic setting, mouse IgG2a isotype is superior to mIgG1 or mIgE in controlling tumor growth

    Get PDF
    UNLABELLED: In the last decades, antibody-based tumor therapy has fundamentally improved the efficacy of treatment for patients with cancer. Currently, almost all tumor antigen-targeting antibodies approved for clinical application are of IgG1 Fc isotype. Similarly, the mouse homolog mIgG2a is the most commonly used in tumor mouse models. However, in mice, the efficacy of antibody-based tumor therapy is largely restricted to a prophylactic application. Direct isotype comparison studies in mice in a therapeutic setting are scarce. In this study, we assessed the efficacy of mouse tumor-targeting antibodies of different isotypes in a therapeutic setting using a highly systematic approach. To this end, we engineered and expressed antibodies of the same specificity but different isotypes, targeting the artificial tumor antigen CD90.1/Thy1.1 expressed by B16 melanoma cells. Our experiments revealed that in a therapeutic setting mIgG2a was superior to both mIgE and mIgG1 in controlling tumor growth. Furthermore, the observed mIgG2a antitumor effect was entirely Fc mediated as the protection was lost when an Fc-silenced mIgG2a isotype (LALA-PG mutations) was used. These data confirm mIgG2a superiority in a therapeutic tumor model. SIGNIFICANCE: Direct comparisons of different antibody isotypes of the same specificity in cancer settings are still scarce. Here, it is shown that mIgG2a has a greater effect compared with mIgG1 and mIgE in controlling tumor growth in a therapeutic setting

    Flip-angle based ratiometric approach for pulsed CEST-MRI pH imaging

    Get PDF
    Several molecules have been exploited for developing MRI pH sensors based on the chemical exchange saturation transfer (CEST) technique. A ratiometric approach, based on the saturation of two exchanging pools at the same saturation power, or by varying the saturation power levels on the same pool, is usually needed to rule out the concentration term from the pH measurement. However, all these methods have been demonstrated by using a continuous wave saturation scheme that limits its translation to clinical scanners. This study shows a new ratiometric CEST-MRI pH-mapping approach based on a pulsed CEST saturation scheme for a radiographic contrast agent (iodixanol) possessing a single chemical exchange site. This approach is based on the ratio of the CEST contrast effects at two different flip angles combinations (180°/360° and 180°/720°), keeping constant the mean irradiation RF power (Bavg power). The proposed ratiometric approach index is concentration independent and it showed good pH sensitivity and accuracy in the physiological range between 6.0 and 7.4

    A data mining approach to the SAR values over large MR image repositories

    Get PDF
    Purpose: In magnetic resonance imaging, the radiofrequency energy absorption arises as one of the main safety concerns, being mainly related with increased body temperature. Monitoring radiofrequency absorption is achieved by the estimation of specific absorption rate (SAR), whose implementation lies on equipment manufacturers, which in turn are not totally enlightening about its calculus. This work presents an exploratory approach of whole-body SAR values stored in DICOM metadata aiming to find correlation with body weight, body mass index (BMI), gender and pulse sequences for abdominal/pelvic (17.812 series) and head (29.907 series) studies. Methods and Materials: All studies were acquired in a 3 Tesla scanner with high-performance gradients. Data were extracted using Dicoogle, a DICOM metadata mining tool. Several DICOM tags were analysed (e.g. patient weight, height, gender, sequence name). For each study type, specifically weighted pulse sequences were related with weight, BMI and gender through boxplot diagrams, statistical and effect size analysis. Results: SAR limits were never exceeded. Generally, SAR values tended to decrease with increasing body weight and BMI values for abdominal/pelvic studies. On the other hand, head studies showed different trends regarding distinct pulse sequences. SAR values tend to be higher in male individuals (p<0,05). As expected, turbo spin echo sequences present the highest SAR values. The values found for echo gradient spoiled sequence (FLASH) were also high. Conclusion: It is confirmed that SAR estimates are related with the analysed variables. An individual examination of pulse sequences is recommended to observe trends regarding weight, BMI or gender.publishe

    The cellular heat shock response monitored by chemical exchange saturation transfer MRI

    Get PDF
    CEST-MRI of the rNOE signal has been demonstrated in vitro to be closely linked to the protein conformational state. As the detectability of denaturation and aggregation processes on a physiologically relevant scale in living organisms has yet to be verified, the aim of this study was to perform heat-shock experiments with living cells to monitor the cellular heat-shock response of the rNOE CEST signal. Cancer cells (HepG2) were dynamically investigated after a mild, non-lethal heat-shock of 42 °C for 20 min using an MR-compatible bioreactor system at 9.4 T. Reliable and fast high-resolution CEST imaging was realized by a relaxation-compensated 2-point contrast metric. After the heat-shock, a substantial decrease of the rNOE CEST signal by 8.0 ± 0.4% followed by a steady signal recovery within a time of 99.1 ± 1.3 min was observed in two independent trials. This continuous signal recovery is in coherence with chaperone-induced refolding of heat-shock induced protein aggregates. We demonstrated that protein denaturation processes influence the CEST-MRI signal on a physiologically relevant scale. Thus, the protein folding state is, along with concentration changes, a relevant physiological parameter for the interpretation of CEST signal changes in diseases that are associated with pathological changes in protein expression, like cancer and neurodegenerative diseases
    corecore