235 research outputs found

    En ocasiĂł d'un centenari: la poesia de Gabriel Alomar

    Get PDF

    Jerusalem

    Get PDF

    AproximaciĂł a Verdaguer

    Get PDF
    Abstract not availabl

    Textos sobre Mort de Dama

    Get PDF

    InmunohistoquĂ­mica

    Get PDF
    Inclou referències bibliogràfique

    Seasonal pattern of the coastal fish assemblage in Anegada Bay, Argentina

    Get PDF
    The seasonal variation of the inshore fish assemblage of Anegada Bay, North Patagonia, Argentina is described here. Three areas were seasonally sampled from 2007 to 2009 by means of a gang of bottom gill-nets. We found 21 coastal fish species, but species richness and fish number and weight changed throughout the year. The six species classified as dominant have national and regional value for artisanal and recreational fishing and were responsible for the seasonal variation in the fish assemblage. Both cluster and non-metric multidimensional scaling analyses based on fish number and fish weight indicated two major sample groups encompassing spring and summer (the warmer seasons) and autumn and winter (the colder seasons). The fish assemblage had higher species richness, dominance and abundance during the warmer seasons than during the colder seasons in the same years and at the same sites. Water temperature was the main environmental factor structuring the fish assemblage in Anegada Bay. We suggest that partial breeding migration toward the bay during warmer months could explain the seasonal pattern observed. Nevertheless, variation in temperature conditions agreed well with the pattern of seasonal changes, leading to an interaction between abiotic and biotic influences in determining the variability in this seasonal fish assemblage. We conclude that an understanding of species temporal and spatial patterns in areas of high ecological and economic value, as exemplified by Anegada Bay, are essential for the implementation of a management approach oriented toward ecosystem sustainability.Fil: Llompart, Facundo Manuel. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro Austral de Investigaciones CientĂ­ficas; ArgentinaFil: Colautti, Dario CĂ©sar. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico La Plata. Instituto de LimnologĂ­a "Dr. Raul A. Ringuelet"; Argentina. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro Austral de Investigaciones CientĂ­ficas; Argentina. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico La Plata. Instituto de Investigaciones BiotecnolĂłgicas - Instituto TecnolĂłgico ChascomĂşs. Instituto de Investigaciones BiotecnolĂłgicas (sede ChascomĂşs); ArgentinaFil: Cruz Gimenez, Adriana Milena. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro Austral de Investigaciones CientĂ­ficas; ArgentinaFil: BaigĂşn, Claudio Rafael M.. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro Austral de Investigaciones CientĂ­ficas; Argentina. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico La Plata. Instituto de Investigaciones BiotecnolĂłgicas - Instituto TecnolĂłgico ChascomĂşs. Instituto de Investigaciones BiotecnolĂłgicas (sede ChascomĂşs); Argentin

    Performance characteristics of the whole-body discovery IQ PET/CT system

    Get PDF
    The aim of this study was to assess the physical performance of a new PET/CT system, the Discovery IQ with 5-ring detector blocks. Methods: Performance was measured using the National Electrical Manufacturers Association NU2-2012 methodology. Image quality was extended by accounting for different acquisition parameters (lesion-to-background ratios [8:1, 4:1, and 2:1] and acquisition times) and reconstruction algorithms (VUE-point HD [VPHD], VPHD with point-spread-function modeling [VPHD-S], and Q.Clear). Tomographic reconstruction was also assessed using a Jaszczak phantom. Additionally, 30 patient lesions were analyzed to account for differences in lesion volume and SUV quantification between reconstruction algorithms. Results: Spatial resolution ranged from 4.2 mm at 1 cm to 8.5 mm at 20 cm. Sensitivity measured at the center and at 10 cm was 22.8 and 20.4 kps/kBq, respectively. The noise-equivalent counting rate peak was 124 kcps at 9.1 kBq/cm3 The scatter fraction was 36.2%. The accuracy of correction for count losses and randoms was 3.9%. In the image quality test, contrast recovery for VPHD, VPHD-S, and Q.Clear ranged from 18%, 18%, and 13%, respectively (hot contrast; 10-mm sphere diameter; ratio, 2:1), to 68%, 67%, and 81%, respectively (cold contrast; 37-mm sphere diameter; ratio, 8:1). Background variability ranged from 3.4%, 3.0%, and 2.1%, respectively (ratio, 2:1), to 5.5%, 4.8%, and 3.7%, respectively (ratio, 8:1). On Q.Clear reconstruction, the decrease in the penalty term (β) increased the contrast recovery coefficients and background variability. With the Jaszczak phantom, image quality increased overall when a reconstruction algorithm modeling the point-spread function was used, and use of Q.Clear increased the signal-to-noise ratio. Lesions analyzed using VPHD-S and Q.Clear had an SUVmean of 6.5 ± 3 and 7 ± 3, respectively (P < 0.01), and an SUVmax of 11 ± 4.8 and 12 ± 4, respectively (P < 0.01). No significant difference in mean lesion volume was found between algorithms. Conclusion: Among the various Discovery bismuth germanium oxide-based PET/CT scanners, the IQ with 5-ring detector blocks has the highest overall performance, with improved sensitivity and counting rate performance. Q.Clear reconstruction improves the PET image quality, with higher recovery coefficients and lower background variability

    Pentobarbital versus thiopental in the treatment of refractory intracranial hypertension in patients with traumatic brain injury: a randomized controlled trial

    Get PDF
    Introduction: Experimental research has demonstrated that the level of neuroprotection conferred by the various barbiturates is not equal. Until now no controlled studies have been conducted to compare their effectiveness, even though the Brain Trauma Foundation Guidelines recommend that such studies be undertaken. The objectives of the present study were to assess the effectiveness of pentobarbital and thiopental in terms of controlling refractory intracranial hypertension in patients with severe traumatic brain injury, and to evaluate the adverse effects of treatment. Methods: This was a prospective, randomized, cohort study comparing two treatments: pentobarbital and thiopental. Patients who had suffered a severe traumatic brain injury (Glasgow Coma Scale score after resuscitation ≤ 8 points or neurological deterioration during the first week after trauma) and with refractory intracranial hypertension (intracranial pressure > 20 mmHg) first-tier measures, in accordance with the Brain Trauma Foundation Guidelines. Results: A total of 44 patients (22 in each group) were included over a 5-year period. There were no statistically significant differences in ' baseline characteristics, except for admission computed cranial tomography characteristics, using the Traumatic Coma Data Bank classification. Uncontrollable intracranial pressure occurred in 11 patients (50%) in the thiopental treatment group and in 18 patients (82%) in the pentobarbital group (P = 0.03). Under logistic regression analysis - undertaken in an effort to adjust for the cranial tomography characteristics, which were unfavourable for pentobarbital - thiopental was more effective than pentobarbital in terms of controlling intracranial pressure (odds ratio = 5.1, 95% confidence interval 1.2 to 21.9; P = 0.027). There were no significant differences between the two groups with respect to the incidence of arterial hypotension or infection. Conclusions: Thiopental appeared to be more effective than pentobarbital in controlling intracranial hypertension refractory to first-tier measures. These findings should be interpreted with caution because of the imbalance in cranial tomography characteristics and the different dosages employed in the two arms of the study. The incidence of adverse effects was similar in both groups

    2-[18F]FDG PET/CT as a Predictor of Microvascular Invasion and High Histological Grade in Patients with Hepatocellular Carcinoma

    Get PDF
    Hepatocellular carcinoma (HCC) generally presents a low avidity for 2-deoxy-2-[18F]fluoro-d-glucose (FDG) in PET/CT although an increased FDG uptake seems to relate to more aggressive biological factors. To define the prognostic value of PET/CT with FDG in patients with an HCC scheduled for a tumor resection, forty-one patients were prospectively studied. The histological factors of a poor prognosis were determined and FDG uptake in the HCC lesions was analyzed semi-quantitatively (lean body mass-corrected standardized uptake value (SUL) and tumor-to-liver ratio (TLR) at different time points). The PET metabolic parameters were related to the histological characteristics of the resected tumors and to the evolution of patients. Microvascular invasion (MVI) and a poor grade of differentiation were significantly related to a worse prognosis. The SULpeak of the lesion 60 min post-FDG injection was the best parameter to predict MVI while the SULpeak of the TLR at 60 min was better for a poor differentiation. Moreover, the latter parameter was also the best preoperative variable available to predict any of these two histological factors. Patients with an increased TLRpeak60 presented a significantly higher incidence of poor prognostic factors than the rest (75% vs. 28.6%, p = 0.005) and a significantly higher incidence of recurrence at 12 months (38% vs. 0%, p = 0.014). Therefore, a semi-quantitative analysis of certain metabolic parameters on PET/CT can help identify, preoperatively, patients with histological factors of a poor prognosis, allowing an adjustment of the therapeutic strategy for those patients with a higher risk of an early recurrence

    Image quality evaluation in a modern PET system: impact of new reconstructions methods and a radiomics approach

    Get PDF
    The present work investigates the influence of different biological and physical parameters on image quality (IQ) perception of the abdominal area in a modern PET scanner, using new reconstruction algorithms and testing the utility of a radiomics approach. Scans of 112 patients were retrospectively included. Images were reconstructed using both OSEM + PSF and BSRM methods, and IQ of the abdominal region was subjectively evaluated. First, 22 IQ related parameters were obtained (including count rate and biological or mixed parameters) and compared to the subjective IQ scores by means of correlations and logistic regression. Second, an additional set of radiomics features was extracted, and a model was constructed by means of an elastic-net regression. For the OSEM + PSF and especially for the BSRM reconstructions, IQ parameters presented only at best moderated correlations with the subjective IQ. None of the studied parameters presented a good predictive power for IQ, while a simple radiomics model increased the performance of the IQ prediction. These results suggest the necessity of changing the standard parameters to evaluate IQ, particularly when a BSRM algorithm is involved. Furthermore, it seems that a simple radiomics model can outperform the use of any single parameter to assess IQ
    • …
    corecore