458 research outputs found

    Optimization, evaluation, and comparison of standard algorithms for image reconstruction with the VIP-PET

    Get PDF
    A novel positron emission tomography (PET) scanner design based on a room-temperature pixelated CdTe solid-state detector is being developed within the framework of the Voxel Imaging PET (VIP) Pathfinder project []. The simulation results show a great potential of the VIP to produce high-resolution images even in extremely challenging conditions such as the screening of a human head []. With unprecedented high channel density (450 channels/cm 3) image reconstruction is a challenge. Therefore optimization is needed to find the best algorithm in order to exploit correctly the promising detector potential. The following reconstruction algorithms are evaluated: 2-D Filtered Backprojection (FBP), Ordered Subset Expectation Maximization (OSEM), List-Mode OSEM (LM-OSEM), and the Origin Ensemble (OE) algorithm. The evaluation is based on the comparison of a true image phantom with a set of reconstructed images obtained by each algorithm. This is achieved by calculation of image quality merit parameters such as the bias, the variance and the mean square error (MSE). A systematic optimization of each algorithm is performed by varying the reconstruction parameters, such as the cutoff frequency of the noise filters and the number of iterations. The region of interest (ROI) analysis of the reconstructed phantom is also performed for each algorithm and the results are compared. Additionally, the performance of the image reconstruction methods is compared by calculating the modulation transfer function (MTF). The reconstruction time is also taken into account to choose the optimal algorithm. The analysis is based on GAMOS [] simulation including the expected CdTe and electronic specifics

    Simulation of charge transport in pixelated CdTe

    Get PDF
    The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated semiconductor technology for nuclear medicine applications to achieve an improved image reconstruction without efficiency loss. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 10 6). The design is based on the use of a pixelated CdTe Schottky detector to have optimal energy and spatial resolution. An individual read-out channel is dedicated for each detector voxel of size 1 × 1 × 2 mm 3 using an application-specific integrated circuit (ASIC) which the VIP project has designed, developed and is currently evaluating experimentally. The behaviour of the signal charge carriers in CdTe should be well understood because it has an impact on the performance of the readout channels. For this purpose the Finite Element Method (FEM) Multiphysics COMSOL software package has been used to simulate the behaviour of signal charge carriers in CdTe and extract values for the expected charge sharing depending on the impact point and bias voltage. The results on charge sharing obtained with COMSOL are combined with GAMOS, a Geant based particle tracking Monte Carlo software package, to get a full evaluation of the amount of charge sharing in pixelated CdTe for different gamma impact points

    Performance of the Electromagnetic Calorimeter of the HERMES Experiment

    Get PDF
    The performance of the electromagnetic calorimeter of the HERMES experiment is described. The calorimeter consists of 840 radiation resistant F101 lead-glass counters. The response to positrons up to 27.5 GeV, the comparison between the measured energy and the momentum reconstructed from tracking, long-term stability, hadron rejection and neutral meson invariant mass reconstruction are shown.Comment: 22 pages, 13 figures, LaTeX, accepted by NI

    Assessment of Existing Steel Structures - Recommendations for Estimation of the Remaining Fatigue Life

    Get PDF
    Due to the demand for freight volume on rail and road, traffic has increased significantly in the past years leading to an increasing number of heavy vehicles in the traffic flows and greater exploitation of their loading capacities. Because of environmental considerations there is also a tendency to further enhance the admissible loads in the design of new heavy vehicles (e.g. by increasing axle loads or using road trains). This all may affect the safety, serviceability and durability of existing bridges. Bridge authorities are therefore interested in agreed methods to assess the safety and durability of existing bridges and to make appropriate provisions for more refined maintenance methods, possible restriction of traffic, bridge-rehabilitation or substitution of old bridges by new ones where necessary. For steel bridges including the old riveted ones there are numerous approaches to such assessments, partly standardized by national codes or recommendations. In the light of the development of the European single market for construction works and engineering services there is thus a need to harmonize them and to develop agreed European technical recommendations for the safety and durability assessment of existing structures. These recommendations should follow the principles and application rules in the Eurocodes and provide a scheme with different levels of analysis: a basic level with general methods and further levels with higher sophistication that call for specific expertise. This technical report on ¿Recommendations for the estimation of remaining fatigue life¿ supported by the ECCS could be used as a basis for harmonizing National procedures and for the further evolution of the Eurocodes.JRC.G.5-European laboratory for structural assessmen

    Measurement of the Stray Light in the Advanced Virgo Input Mode Cleaner Cavity using an instrumented baffle

    Full text link
    A new instrumented baffle was installed in Spring 2021 at Virgo surrounding the suspended mirror in the input mode cleaner triangular cavity. It serves as a demonstrator of the technology designed to instrument the baffles in the main arms in the near future. We present, for the first time, results on the measured scattered light distribution inside the cavity as determined by the new device using data collected between May and July 2021, with Virgo in commissioning phase and operating with an input laser power in the cavity of 28.5~W. The sensitivity of the baffle is discussed and the data is compared to scattered light simulations.Comment: 4 pages, 5 figures, 1 tabl

    An instrumented baffle for the Advanced Virgo Input Mode Cleaner End Mirror

    Get PDF
    A novel instrumented baffle surrounding the suspended end mirror in the input mode cleaner cavity of the Virgo interferometer was installed in spring 2021. Since then, the device has been regularly operated in the experiment and the obtained results indicate a good agreement with simulations of the stray light inside the optical cavity. The baffle will operate in the upcoming O4 observation run, serving as a demonstrator of the technology designed to instrument the baffles in front of the main mirrors in time for O5. In this paper we present a detailed description of the baffle design, including mechanics, front-end electronics, data acquisition, as well as optical and vacuum tests, calibration and installation procedures, and performance results.Comment: 12 pages, 21 figures, 3 tables, to be submitted to PR

    Measurement of Angular Distributions and R= sigma_L/sigma_T in Diffractive Electroproduction of rho^0 Mesons

    Full text link
    Production and decay angular distributions were extracted from measurements of exclusive electroproduction of the rho^0(770) meson over a range in the virtual photon negative four-momentum squared 0.5< Q^2 <4 GeV^2 and the photon-nucleon invariant mass range 3.8< W <6.5 GeV. The experiment was performed with the HERMES spectrometer, using a longitudinally polarized positron beam and a ^3He gas target internal to the HERA e^{+-} storage ring. The event sample combines rho^0 mesons produced incoherently off individual nucleons and coherently off the nucleus as a whole. The distributions in one production angle and two angles describing the rho^0 -> pi+ pi- decay yielded measurements of eight elements of the spin-density matrix, including one that had not been measured before. The results are consistent with the dominance of helicity-conserving amplitudes and natural parity exchange. The improved precision achieved at 47 GeV, reveals evidence for an energy dependence in the ratio R of the longitudinal to transverse cross sections at constant Q^2.Comment: 15 pages, 15 embedded figures, LaTeX for SVJour(epj) document class Revision: Fig. 15 corrected, recent data added to Figs. 10,12,14,15; minor changes to tex

    The Flavor Asymmetry of the Light Quark Sea from Semi-inclusive Deep-inelastic Scattering

    Get PDF
    The flavor asymmetry of the light quark sea of the nucleon is determined in the kinematic range 0.02<x<0.3 and 1 GeV^2<Q^2<10 GeV^2, for the first time from semi-inclusive deep-inelastic scattering. The quantity (dbar(x)-ubar(x))/(u(x)-d(x)) is derived from a relationship between the yields of positive and negative pions from unpolarized hydrogen and deuterium targets. The flavor asymmetry dbar-ubar is found to be non-zero and x dependent, showing an excess of dbar over ubar quarks in the proton.Comment: 7 Pages, 2 figures, RevTeX format; slight revision in text, small change in extraction of dbar-ubar and comparison with a high q2 parameterizatio

    Beam-Induced Nuclear Depolarisation in a Gaseous Polarised Hydrogen Target

    Get PDF
    Spin-polarised atomic hydrogen is used as a gaseous polarised proton target in high energy and nuclear physics experiments operating with internal beams in storage rings. When such beams are intense and bunched, this type of target can be depolarised by a resonant interaction with the transient magnetic field generated by the beam bunches. This effect has been studied with the HERA positron beam in the HERMES experiment at DESY. Resonances have been observed and a simple analytic model has been used to explain their shape and position. Operating conditions for the experiment have been found where there is no significant target depolarisation due to this effect.Comment: REVTEX, 6 pages, 5 figure