362 research outputs found

    Survival After Endovascular Therapy in Patients With Type B Aortic Dissection A Report From the International Registry of Acute Aortic Dissection (IRAD)

    Get PDF
    ObjectivesThis study sought to evaluate long-term survival in type B aortic dissection patients treated with thoracic endovascular aortic repair (TEVAR) therapy.BackgroundHistorical data have supported medical therapy in type B acute aortic dissection (TBAAD) patients. Recent advances in TEVAR appear to improve in-hospital mortality.MethodsWe examined 1,129 consecutive patients with TBAAD enrolled in IRAD (International Registry of Acute Aortic Dissection) between 1995 and 2012 who received medical (n = 853, 75.6%) or TEVAR (n = 276, 24.4%) therapy.ResultsClinical history was similar between groups. TEVAR patients were more likely to present with a pulse deficit (28.3% vs. 13.4%, p < 0.001) and lower extremity ischemia (16.8% vs. 3.6%, p < 0.001), and to characterize their pain as the “worst pain ever” (27.5% vs. 15.7%, p < 0.001). TEVAR patients were also most likely to present with complicated acute aortic dissection, defined as shock, periaortic hematoma, signs of malperfusion, stroke, spinal cord ischemia, mesenteric ischemia, and/or renal failure (61.7% vs. 37.2%). In-hospital mortality was similar in patients managed with endovascular repair (10.9 % vs. 8.7%, p = 0.273) compared with medically managed patients. One-year mortality was also similar in both groups (8.1% endovascular vs. 9.8% medical, p = 0.604). Among adverse events during follow-up, aortic growth/new aneurysm was most common, occurring in 73.3% of patients with medical therapy and in 62.7% of patients after TEVAR, based on 5-year Kaplan-Meier estimates. Kaplan-Meier survival estimates showed that patients undergoing TEVAR had a lower death rate (15.5% vs. 29.0%, p = 0.018) at 5 years.ConclusionsResults from IRAD show that TEVAR is associated with lower mortality over a 5-year period than medical therapy for TBAAD. Further randomized trials with long-term follow-up are needed

    Patients with type A acute aortic dissection presenting with major brain injury: Should we operate on them?

    Get PDF
    none20siopenDi Eusanio, Marco*; Patel, Himanshu J.; Nienaber, Christoph A.; Montgomery, Daniel M.; Korach, Amit; Sundt, Thoralf M.; Devincentiis, Carlo; Voehringer, Matthias; Peterson, Mark D.; Myrmel, Truls; Folesani, Gianluca; Larsen, Magnus; Desai, Nimesh D.; Bavaria, Joseph E.; Appoo, Jehangir J.; Kieser, Teresa M.; Fattori, Rossella; Eagle, Kim; Di Bartolomeo, Roberto; Trimarchi, SantiDi Eusanio, Marco; Patel, Himanshu J.; Nienaber, Christoph A.; Montgomery, Daniel M.; Korach, Amit; Sundt, Thoralf M.; Devincentiis, Carlo; Voehringer, Matthias; Peterson, Mark D.; Myrmel, Truls; Folesani, Gianluca; Larsen, Magnus; Desai, Nimesh D.; Bavaria, Joseph E.; Appoo, Jehangir J.; Kieser, Teresa M.; Fattori, Rossella; Eagle, Kim; Di Bartolomeo, Roberto; Trimarchi, Sant

    Presentation, Diagnosis, and Outcomes of Acute Aortic Dissection: 17-Year Trends From the International Registry of Acute Aortic Dissection

    Get PDF
    none17siDiagnosis, treatment, and outcomes of acute aortic dissection (AAS) are changing.openPape, Linda A; Awais, Mazen; Woznicki, Elise M; Suzuki, Toru; Trimarchi, Santi; Evangelista, Arturo; Myrmel, Truls; Larsen, Magnus; Harris, Kevin M; Greason, Kevin; Di Eusanio, Marco; Bossone, Eduardo; Montgomery, Daniel G; Eagle, Kim A; Nienaber, Christoph A; Isselbacher, Eric M; O'Gara, PatrickPape, Linda A; Awais, Mazen; Woznicki, Elise M; Suzuki, Toru; Trimarchi, Santi; Evangelista, Arturo; Myrmel, Truls; Larsen, Magnus; Harris, Kevin M; Greason, Kevin; Di Eusanio, Marco; Bossone, Eduardo; Montgomery, Daniel G; Eagle, Kim A; Nienaber, Christoph A; Isselbacher, Eric M; O'Gara, Patric

    Results from the first use of low radioactivity argon in a dark matter search

    Get PDF
    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).Comment: Accepted by Phys. Rev.

    The ARCH Projects: design and rationale (IAASSG 001)

    Get PDF
    OBJECTIVE A number of factors limit the effectiveness of current aortic arch studies in assessing optimal neuroprotection strategies, including insufficient patient numbers, heterogenous definitions of clinical variables, multiple technical strategies, inadequate reporting of surgical outcomes and a lack of collaborative effort. We have formed an international coalition of centres to provide more robust investigations into this topic. METHODS High-volume aortic arch centres were identified from the literature and contacted for recruitment. A Research Steering Committee of expert arch surgeons was convened to oversee the direction of the research. RESULTS The International Aortic Arch Surgery Study Group has been formed by 41 arch surgeons from 10 countries to better evaluate patient outcomes after aortic arch surgery. Several projects, including the establishment of a multi-institutional retrospective database, randomized controlled trials and a prospectively collected database, are currently underway. CONCLUSIONS Such a collaborative effort will herald a turning point in the surgical management of aortic arch pathologies and will provide better powered analyses to assess the impact of varying surgical techniques on mortality and morbidity, identify predictors for neurological and operative risk, formulate and validate risk predictor models and review long-term survival outcomes and quality-of-life after arch surger

    Brief review on systematic hypothermia for the protection of central nervous system during aortic arch surgery: a double-sword tool?

    Get PDF
    Antegrade selective cerebral perfusion in conjunction with hypothermia attenuate postoperative neurological injury, which in turn still remains the main cause of mortality and morbidity following aortic arch surgery. Hypothermic circulatory arrest however could be a useful tool during arch surgery, surgery for chronic thromboembolic disease, air on the arterial line during CPB, during cavotomy for extraction of renal cell carcinoma with level IV extension, or when dealing with difficult trauma to the SVC or IVC. Cerebral protective effects with hypothermic procedures including inhibition of neuron excitation, and discharge of excitable amino acids, and thereby, prevention of an increase in intercellular calcium ions, hyperoxidation of lipids in cell membranes, and free radical production

    DarkSide status and prospects

    Get PDF
    Sem informaçãoDarkSide uses a dual-phase Liquid Argon Time Projection Chamber to search for WIMP dark matter. The current detector, DarkSide-50, is running since mid 2015 with a target of 50 kg of Argon from an underground source. Here it is presented the latest results of searches of WIMP-nucleus interactions, with WIMP masses in the GeV-TeV range, and of WIMP-electron interactions, in the sub-GeV mass range. The future of DarkSide with a new generation experiment, involving a global collaboration from all the current Argon based experiments, is presented.422-315Sem informaçãoSem informaçãoSem informaçã

    DarkSide-50 532-day dark matter search with low-radioactivity argon

    Get PDF
    FAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULOThe DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16 660 +/- 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C. L. upper limit on the dark matter-nucleon spin-independent cross section of 1.14 x 10(-44) cm(2) (3.78 x 10(-44) cm(2), 3.43 x 10(-43) cm(2)) for a WIMP mass of 100 GeV/c(2) (1 TeV/c(2), 10 TeV/c(2)).9810117FAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULOFAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO2016/09084-0Agências de fomento estrangeiras apoiaram essa pesquisa, mais informações acesse artig
    corecore