5,080 research outputs found
KamLAND Bounds on Solar Antineutrinos and neutrino transition magnetic moments
We investigate the possibility of detecting solar electron antineutrinos with
the KamLAND experiment. These electron antineutrinos are predicted by
spin-flavor oscillations at a significant rate even if this mechanism is not
the leading solution to the SNP. KamLAND is sensitive to antineutrinos
originated from solar B neutrinos. From KamLAND negative results after
145 days of data taking, we obtain model independent limits on the total flux
of solar electron antineutrinos $\Phi({}^8 B)< 1.1-3.5\times 10^4 cm^{-2}\
s^{-1}P<0.15%\mu B< 2.3\times 10^{-21}(\Delta m^2, \tan^2\theta)\mu\lsim 3.9\times 10^{-12} \mu_BB= 50\mu\lsim 9.0\times 10^{-13} \mu_BB= 200\mu\lsim 2.0\times 10^{-13} \mu_BB= 1000$ kG at the same
statistical significance.Comment: 13 pages, 2 figure
Neutrino Magnetic Moments and Minimal Supersymmetric SO(10) Model
We examine supersymmetric contributions to transition magnetic moments of
Majorana neutrinos. We first give the general formula for it. In concrete
evaluations, informations of neutrino mass matrix elements including CP phases
are necessary. Using unambiguously determined neutrino mass matrices in
recently proposed minimal supersymmetric SO(10) model, the transition magnetic
moments are calculated. The resultant neutrino magnetic moments are found to be
roughly an order of magnitude larger than those calculated in the standard
model extended to incorporate the see-saw mechanism.Comment: 8 pages, 4 figures, the version to be published in International
Journal of Modern Physics
Dysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis.
PURPOSE:Confocal adaptive optics scanning laser ophthalmoscope (AOSLO) images provide a sensitive measure of cone structure. However, the relationship between structural findings of diminished cone reflectivity and visual function is unclear. We used fundus-referenced testing to evaluate visual function in regions of apparent cone loss identified using confocal AOSLO images. METHODS:A patient diagnosed with acute bilateral foveolitis had spectral-domain optical coherence tomography (SD-OCT) (Spectralis HRA + OCT system [Heidelberg Engineering, Vista, CA, USA]) images indicating focal loss of the inner segment-outer segment junction band with an intact, but hyper-reflective, external limiting membrane. Five years after symptom onset, visual acuity had improved from 20/80 to 20/25, but the retinal appearance remained unchanged compared to 3 months after symptoms began. We performed structural assessments using SD-OCT, directional OCT (non-standard use of a prototype on loan from Carl Zeiss Meditec) and AOSLO (custom-built system). We also administered fundus-referenced functional tests in the region of apparent cone loss, including analysis of preferred retinal locus (PRL), AOSLO acuity, and microperimetry with tracking SLO (TSLO) (prototype system). To determine AOSLO-corrected visual acuity, the scanning laser was modulated with a tumbling E consistent with 20/30 visual acuity. Visual sensitivity was assessed in and around the lesion using TSLO microperimetry. Complete eye examination, including standard measures of best-corrected visual acuity, visual field tests, color fundus photos, and fundus auto-fluorescence were also performed. RESULTS:Despite a lack of visible cone profiles in the foveal lesion, fundus-referenced vision testing demonstrated visual function within the lesion consistent with cone function. The PRL was within the lesion of apparent cone loss at the fovea. AOSLO visual acuity tests were abnormal, but measurable: for trials in which the stimulus remained completely within the lesion, the subject got 48% correct, compared to 78% correct when the stimulus was outside the lesion. TSLO microperimetry revealed reduced, but detectible, sensitivity thresholds within the lesion. CONCLUSIONS AND IMPORTANCE:Fundus-referenced visual testing proved useful to identify functional cones despite apparent photoreceptor loss identified using AOSLO and SD-OCT. While AOSLO and SD-OCT appear to be sensitive for the detection of abnormal or absent photoreceptors, changes in photoreceptors that are identified with these imaging tools do not correlate completely with visual function in every patient. Fundus-referenced vision testing is a useful tool to indicate the presence of cones that may be amenable to recovery or response to experimental therapies despite not being visible on confocal AOSLO or SD-OCT images
First report of a primitive neuroectodermal tumor of the bladder in a newborn
Primitive neuroectodermal tumor (PNET) is part of the Ewing sarcoma family of tumors. The present case reports a primitive neuroectodermal tumor (PNET) of rare location in the bladder in a newborn. It was evaluated with prenatal ultrasound and postnatal tomography that revealed a mass in the posterior wall of the bladder. The patient underwent partial cystectomy with subsequent analysis of the surgical piece removed, the histopathological study indicated a tumor of mesenchymal origin, and immunohistochemical staining confirmed the diagnosis of PNET of the bladder. Satisfactory result and short-term follow-up.RevisiĂłn por pare
Chiral symmetry breaking for deterministic switching of perpendicular magnetization by spin-orbit torque
Symmetry breaking is a characteristic to determine which branch of a
bifurcation system follows upon crossing a critical point. Specifically, in
spin-orbit torque (SOT) devices, a fundamental question arises: how to break
the symmetry of the perpendicular magnetic moment by the in-plane spin
polarization? Here, we show that the chiral symmetry breaking by the DMI can
induce the deterministic SOT switching of the perpendicular magnetization. By
introducing a gradient of saturation magnetization or magnetic anisotropy,
non-collinear spin textures are formed by the gradient of effective SOT
strength, and thus the chiral symmetry of the SOT-induced spin textures is
broken by the DMI, resulting in the deterministic magnetization switching. We
introduce a strategy to induce an out-of-plane (z) gradient of magnetic
properties, as a practical solution for the wafer-scale manufacture of SOT
devices.Comment: 16 pages, 4 figure
Accounting for centerâofâmass target motion using convolution methods in Monte Carloâbased dose calculations of the lung
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/134807/1/mp9083.pd
Two Gallium data sets, spin flavour precession and KamLAND
We reexamine the possibility of a time modulation of the low energy solar
neutrino flux which is suggested by the average decrease of the Ga data in line
with our previous arguments. We perform two separate fits to the solar neutrino
data, one corresponding to 'high' and the other to 'low' Ga data, associated
with low and high solar activity respectively. We therefore consider an
alternative to the conventional solar+KamLAND fitting, which allows one to
explore the much wider range of the angle permitted by the
KamLAND fitting alone. We find a solution with parameters in which the 'high' and
the 'low' Ga rates lie far apart and are close to their central values and is
of comparable quality to the global best fit, where these rates lie much closer
to each other. This is an indication that the best fit in which all solar and
KamLAND data are used is not a good measure of the separation of the two Ga
data sets, as the information from the low energy neutrino modulation is
dissimulated in the wealth of data. Furthermore for the parameter set proposed
one obtains an equally good fit to the KamLAND energy spectrum and an even
better fit than the 'conventional' LMA one for the reactor antineutrino
survival probability as measured by KamLAND.Comment: V2: 15 pages, 3 eps figures, fit improved, final version to appear in
Journal of Physics
Constraining the neutrino magnetic moment with anti-neutrinos from the Sun
We discuss the impact of different solar neutrino data on the
spin-flavor-precession (SFP) mechanism of neutrino conversion. We find that,
although detailed solar rates and spectra allow the SFP solution as a
sub-leading effect, the recent KamLAND constraint on the solar antineutrino
flux places stronger constraints to this mechanism. Moreover, we show that for
the case of random magnetic fields inside the Sun, one obtains a more stringent
constraint on the neutrino magnetic moment down to the level of \mu_\nu \lsim
few \times 10^{-12}\mu_B, similar to bounds obtained from star cooling.Comment: 4 pages, 3 figures. Final version to appear in Phys. Rev. Let
The Reliability of Parafoveal Cone Density Measurements
Background Adaptive optics scanning light ophthalmoscopy (AOSLO) enables direct visualisation of the cone mosaic, with metrics such as cone density and cell spacing used to assess the integrity or health of the mosaic. Here we examined the interobserver and inter-instrument reliability of cone density measurements.
Methods For the interobserver reliability study, 30 subjects with no vision-limiting pathology were imaged. Three image sequences were acquired at a single parafoveal location and aligned to ensure that the three images were from the same retinal location. Ten observers used a semiautomated algorithm to identify the cones in each image, and this was repeated three times for each image. To assess inter-instrument reliability, 20 subjects were imaged at eight parafoveal locations on one AOSLO, followed by the same set of locations on the second AOSLO. A single observer manually aligned the pairs of images and used the semiautomated algorithm to identify the cones in each image.
Results Based on a factorial study design model and a variance components model, the interobserver study\u27s largest contribution to variability was the subject (95.72%) while the observer\u27s contribution was only 1.03%. For the inter-instrument study, an average cone density intraclass correlation coefficient (ICC) of between 0.931 and 0.975 was calculated.
Conclusions With the AOSLOs used here, reliable cone density measurements can be obtained between observers and between instruments. Additional work is needed to determine how these results vary with differences in image quality
- âŠ