31 research outputs found

    Treatment of non-restrictive cor triatriatum sinister during concomitant cardiac surgery

    Get PDF
    Abstract Background Cor triatriatum is a rare congenital heart disease representing the 0.4% of all congenital cardiac anomalies. To date, no specific genetic alteration has been associated to cor triatriatum. The left-sided presentation (cor triatriatum sinister (CTS)) generally consists in a fibromuscular membrane that divides the left atrium into two chambers, therefore generating a varying grade of flow obstruction depending on the shape, location, and membrane fenestration size. Cor triatriatum sinister can be isolated or associated to other congenital heart defects such as ostium secundum atrial septal defect, patent foramen ovale or abnormal pulmonary veins drainage. Case presentation Our case is a 63-year-old woman who was diagnosed with a non-restrictive membrane during a hospitalization for acute heart failure. In the following 6 months, she started to become symptomatic. However, the onset of symptoms was more likely related to mitral valve regurgitation worsening and previously unknown coronary artery disease, rather than to CTS. She underwent bi-atrial surgical ablation (Cox Maze IV procedure) for atrial fibrillation (AF), surgical resection of interatrial membrane with mitral annuloplasty, and myocardial revascularization. Conclusion The onset and severity of symptoms in patients with CTS mostly depend on membrane fenestration size, grade of stenosis generated and pulmonary veins drainage site. However, some cases may remain asymptomatic until adulthood; the degree of pulmonary hypertension and congestive heart failure is determined by the presence of additional cardiac anomalies and the fibromuscular membrane fenestration. In some cases, CTS may remain asymptomatic, thus the diagnosis can be incidental

    Rhythm outcomes of minimally-invasive off-pump surgical versus catheter ablation in atrial fibrillation: A meta-analysis of reconstructed time-to-event data

    Get PDF
    Background: Mid- and long-term rhythm outcomes of catheter ablation (CA) for atrial fibrillation (AF) are reported to be suboptimal. Minimally invasive surgical off-pump ablation (MISOA), including both thoracoscopic and trans-diaphragmatic approaches, has been developed to reduce surgical invasiveness and overcome on-pump surgery drawbacks. We sought to compare the efficacy and safety of MISOA and CA for AF treatment. Methods: A systematic review and meta-analysis of the literature was performed including studies comparing MISOA and CA. The primary endpoint was survival freedom from AF at follow-up after a 3-month blanking period. Subgroup analysis of the primary endpoint was performed according to the type of surgical incision and hybrid approach. Results: Freedom from AF at 4 years was 52.1% ± 3.2% vs 29.1% ± 3.5%, between MISOA and CA respectively (log-rank p < 0.001; Hazard Ratio: 0.60 [95%Confidence Interval (CI):0.50-0.72], p < 0.001). At landmark analysis, a significant improvement in rhythm outcomes was observed in the MISOA group after the 5th month of follow-up (2 months from the blanking period). The Odds Ratio between MISOA and CA of postoperative cerebrovascular accident incidence and postoperative permanent pacemaker implant (PPM) were 2.00 (95%CI:0.91-4.40, p = 0.084) and 1.55 (95%CI:0.61-3.95, p = 0.358), respectively. The incidence rate ratio of late CVA between MISOA and CA was 0.86 (95%CI:0.28-2.65, p = 0.787), while for late PPM implant was 0.45 (95%CI:0.11-1.78, p = 0.256). Conclusions: The current meta-analysis suggests that MISOA provides superior rhythm outcomes when compared to CA in terms of sinus rhythm restoration. Despite the rhythm outcome superiority of MISOA, it is associated to higher postoperative complications compared to CA

    Minimally Invasive Aortic Valve Replacement with Sutureless Valves:Results From an International Prospective Registry

    Get PDF
    Objective: To report the early and mid-term results of patients who underwent minimally invasive aortic valve replacement (MI-AVR) with a sutureless prosthesis from an international prospective registry. Methods: Between March 2011 and September 2018, among 957 patients included in the prospective observational SURE-AVR (Sorin Universal REgistry on Aortic Valve Replacement) registry, 480 patients underwent MI-AVR with self-expandable Perceval aortic bioprosthesis (LivaNova PLC, London, UK) in 29 international institutions through either minithoracotomy (n = 266) or ministernotomy (n = 214). Postoperative, follow-up, and echocardiographic outcomes were analyzed for all patients. Results: Patient age was 76.1 ± 7.1 years; 64.4% were female. Median EuroSCORE I was 7.9% (interquartile range [IQR], 4.8 to 10.9). Median cardiopulmonary bypass and cross-clamp times were 81 minutes (IQR 64 to 100) and 51 minutes (IQR 40 to 63). First successful implantation was achieved in 97.9% of cases. Two in-hospital deaths occurred, 1 for noncardiovascular causes and 1 following a disabling stroke. In the early (≤30 days) period, stroke rate was 1.4%. Three early explants were reported: 2 due to nonstructural valve dysfunction (NSVD) and 1 for malpositioning. One mild and 1 moderate paravalvular leak were reported. In 16 patients (3.3%) pacemaker implantation was needed. Mean follow-up was 2.4 years (maximum = 7 years). During follow-up 5 explants were reported, 3 due to endocarditis and 2 due to NSVD. Follow-up stroke rate was 2.5%. Three structural valve deteriorations not requiring reintervention were reported. Five-year survival was 91.45%. Conclusions: In this large prospective international registry, MI-AVR with Perceval valve confirmed to be safe, reproducible, and effective in an intermediate-risk population, providing excellent clinical recovery both in early and mid-term follow-up

    Cerebral Perfusion and Neuromonitoring during Complex Aortic Arch Surgery: A Narrative Review

    Get PDF
    : Complex ascending and aortic arch surgery requires the implementation of different cerebral protection strategies to avoid or limit the probability of intraoperative brain damage during circulatory arrest. The etiology of the damage is multifactorial, involving cerebral embolism, hypoperfusion, hypoxia and inflammatory response. These protective strategies include the use of deep or moderate hypothermia to reduce the cerebral oxygen consumption, allowing the toleration of a variable period of absence of cerebral blood flow, and the use of different cerebral perfusion techniques, both anterograde and retrograde, on top of hypothermia, to avoid any period of intraoperative brain ischemia. In this narrative review, the pathophysiology of cerebral damage during aortic surgery is described. The different options for brain protection, including hypothermia, anterograde or retrograde cerebral perfusion, are also analyzed, with a critical review of the advantages and limitations under a technical point of view. Finally, the current systems of intraoperative brain monitoring are also discussed

    Perceval valve intermediate outcomes: a systematic review and meta-analysis at 5-year follow-up

    Get PDF
    ObjectivesNew technologies for the treatment of Aortic Stenosis are evolving to minimize risk and treat an increasingly comorbid population. The Sutureless Perceval Valve is one such alternative. Whilst short-term data is promising, limited mid-term outcomes exist, until now. This is the first systematic review and meta-analysis to evaluate mid-term outcomes in the Perceval Valve in isolation.MethodsA systematic literature review of 5 databases was performed. Articles included evaluated echocardiographic and mortality outcomes beyond 5 years in patients who had undergone Perceval Valve AVR. Two reviewers extracted and reviewed the articles. Weighted estimates were performed for all post-operative and mid-term data. Aggregated Kaplan Meier curves were reconstructed from digitised images to evaluate long-term survival.ResultsSeven observational studies were identified, with a total number of 3196 patients analysed. 30-day mortality was 2.5%. Aggregated survival at 1, 2, 3, 4 and 5 years was 93.4%, 89.4%, 84.9%, 82% and 79.5% respectively. Permanent pacemaker implantation (7.9%), severe paravalvular leak (1.6%), structural valve deterioration (1.5%), stroke (4.4%), endocarditis (1.6%) and valve explant (2.3%) were acceptable at up to mid-term follow up. Haemodynamics were also acceptable at up mid-term with mean-valve gradient (range 9-13.6 mmHg), peak-valve gradient (17.8-22.3 mmHg) and effective orifice area (1.5-1.8 cm(2)) across all valve sizes. Cardiopulmonary bypass (78 min) and Aortic cross clamp times (52 min) were also favourable.ConclusionTo our knowledge, this represents the first meta-analysis to date evaluating mid-term outcomes in the Perceval Valve in isolation and demonstrates good 5-year mortality, haemodynamic and morbidity outcomes.Key questionWhat are the mid-term outcomes at up to 5 years follow up in Perceval Valve Aortic Valve Replacement?Key findingsPerceval Valve AVR achieves 80% freedom from mortality at 5 years with low valve gradients and minimal morbidity.Key outcomesPerceval Valve Aortic Valve Replacement has acceptable mid-term mortality, durability and haemodynamic outcomes

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Rapid Explantation of Rapid-Deployment Sutureless Valve in Case of Acute Endocarditis: How to Remove Safely Sutureless Perceval S Prostheses

    No full text
    We report a case of infective endocarditis on a Perceval S aortic valve bioprosthesis, and we describe a feasible and useful technique that can help remove the infected valve. These maneuvers consist of an “x-movement” reached with the aid of anatomical forceps. The risk of infective endocarditis in patients with prosthetic valves is a well-known phenomena in cardiac surgery, and it can represent a life-threatening event in many cases. According to guidelines, an emergency surgical intervention is required in case of high risk of embolization, vegetation superior than 1 cm or acute cardiac failure secondary to the acute valve dysfunction. In the reported case, the patient was submitted to emergency surgery because of vegetation with diameter superior to 1 cm on the aortic bioprosthesis. The described “x-movement” technique allowed an easily “en block” excision of the damaged bio-prostheses together with vegetation, minimizing the risk of vegetation fragmentation. © 2017 International Society for Minimally Invasive Cardiothoracic Surgery

    Long term follow-up of total arterial versus conventional and hybrid myocardial revascularization: A propensity score matched analysis

    No full text
    To evaluate the impact of the revascularization technique (by means of conventional, total arterial or hybrid myocardial revascularization) in patients with multivessel coronary artery disease
    corecore