2,039 research outputs found
Real Time Global Tests of the ALICE High Level Trigger Data Transport Framework
The High Level Trigger (HLT) system of the ALICE experiment is an online
event filter and trigger system designed for input bandwidths of up to 25 GB/s
at event rates of up to 1 kHz. The system is designed as a scalable PC cluster,
implementing several hundred nodes. The transport of data in the system is
handled by an object-oriented data flow framework operating on the basis of the
publisher-subscriber principle, being designed fully pipelined with lowest
processing overhead and communication latency in the cluster. In this paper, we
report the latest measurements where this framework has been operated on five
different sites over a global north-south link extending more than 10,000 km,
processing a ``real-time'' data flow.Comment: 8 pages 4 figure
Breakup Conditions of Projectile Spectators from Dynamical Observables
Momenta and masses of heavy projectile fragments (Z >= 8), produced in
collisions of 197Au with C, Al, Cu and Pb targets at E/A = 600 MeV, were
determined with the ALADIN magnetic spectrometer at SIS. An analysis of
kinematic correlations between the two and three heaviest projectile fragments
in their rest frame was performed. The sensitivity of these correlations to the
conditions at breakup was verified within the schematic SOS-model. The data
were compared to calculations with statistical multifragmentation models and to
classical three-body calculations. Classical trajectory calculations reproduce
the dynamical observables. The deduced breakup parameters, however, differ
considerably from those assumed in the statistical multifragmentation models
which describe the charge correlations. If, on the other hand, the analysis of
kinematic and charge correlations is performed for events with two and three
heavy fragments produced by statistical multifragmentation codes, a good
agreement with the data is found with the exception that the fluctuation widths
of the intrinsic fragment energies are significantly underestimated. A new
version of the multifragmentation code MCFRAG was therefore used to investigate
the potential role of angular momentum at the breakup stage. If a mean angular
momentum of 0.75/nucleon is added to the system, the energy fluctuations
can be reproduced, but at the same time the charge partitions are modified and
deviate from the data.
PACS numbers: 25.70.Mn, 25.70.Pq, 25.75.Ld, 25.75.-qComment: 38 pages, RevTeX with 21 included figures; Also available from
http://www-kp3.gsi.de/www/kp3/aladin_publications.htm
Thermal and Chemical Freeze-out in Spectator Fragmentation
Isotope temperatures from double ratios of hydrogen, helium, lithium,
beryllium, and carbon isotopic yields, and excited-state temperatures from
yield ratios of particle-unstable resonances in 4He, 5Li, and 8Be, were
determined for spectator fragmentation, following collisions of 197Au with
targets ranging from C to Au at incident energies of 600 and 1000 MeV per
nucleon. A deviation of the isotopic from the excited-state temperatures is
observed which coincides with the transition from residue formation to
multi-fragment production, suggesting a chemical freeze-out prior to thermal
freeze-out in bulk disintegrations.Comment: 14 pages, 10 figures, submitted to Phys. Rev. C, small changes as
suggested by the editors and referee
Transition Radiation Spectroscopy with Prototypes of the ALICE TRD
We present measurements of the transition radiation (TR) spectrum produced in
an irregular radiator at different electron momenta. The data are compared to
simulations of TR from a regular radiator.Comment: 4 pages, 5 Figures, Proceedings for "TRDs for the 3rd millennium"
(Sept. 4-7, 2003, Bari, Italy
Energy loss of pions and electrons of 1 to 6 GeV/c in drift chambers operated with Xe,CO2(15%)
We present measurements of the energy loss of pions and electrons in drift
chambers operated with a Xe,CO2(15%) mixture. The measurements are carried out
for particle momenta from 1 to 6 GeV/c using prototype drift chambers for the
ALICE TRD. Microscopic calculations are performed using input parameters
calculated with GEANT3. These calculations reproduce well the measured average
and most probable values for pions, but a higher Fermi plateau is required in
order to reproduce our electron data. The widths of the measured distributions
are smaller for data compared to the calculations. The electron/pion
identification performance using the energy loss is also presented.Comment: 15 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth.
Space charge in drift chambers operated with the Xe,CO2(15%) mixture
Using prototype modules of the ALICE Transition Radiation Detector we
investigate space charge effects and the dependence of the pion rejection
performance on the incident angle of the ionizing particle. The average pulse
height distributions in the drift chambers operated with the Xe,CO2(15%)
mixture provide quantitative information on the gas gain reduction due to space
charge accumulating during the drift of the primary ionization. Our results
demonstrate that the pion rejection performance of a TRD is better for tracks
which are not at normal incidence to the anode wires. We present detailed
simulations of detector signals, which reproduce the measurements and lend
strong support to our interpretation of the measurements in terms of space
charge effects.Comment: 18 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth.
A. Data files available at http://www-alice.gsi.de/tr
Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%)
We present measurements of position and angular resolution of drift chambers
operated with a Xe,CO(15%) mixture. The results are compared to Monte Carlo
simulations and important systematic effects, in particular the dispersive
nature of the absorption of transition radiation and non-linearities, are
discussed. The measurements were carried out with prototype drift chambers of
the ALICE Transition Radiation Detector, but our findings can be generalized to
other drift chambers with similar geometry, where the electron drift is
perpendicular to the wire planes.Comment: 30 pages, 18 figure
Statistical signatures of critical behavior in small systems
The cluster distributions of different systems are examined to search for
signatures of a continuous phase transition. In a system known to possess such
a phase transition, both sensitive and insensitive signatures are present;
while in systems known not to possess such a phase transition, only insensitive
signatures are present. It is shown that nuclear multifragmentation results in
cluster distributions belonging to the former category, suggesting that the
fragments are the result of a continuous phase transition.Comment: 31 pages, two columns with 30 figure
The ALICE DAQ: Current Status and Future Challenges
Proposal of abstract for CHEP2000The ALICE DAQ system has been designed to support an aggregate eventr building bandwidth of up to 2.5 GByte/s and a storage capability o fup to 1.25 GByte/s to mass storage.A general framework called the ALICE Data Acquisition Test Environment (DATE) system has been developed as a basis for prototyping the components of the DAQ. DATE supports a wide spectrum of configurations from simple systems to more complex systems with multiple detectors and multiple event builders.Prototypes of several key components of the ALICE DAQ have been developed and integrated with the DATE system, such as the ALICE Detector Data Link, the online data monitoring from ROOT and the interface to the Mass Storage systems. Combined tests of several of these components are pursued during the ALICE Data Challenges.The architecture of the ALICE DAQ system will be presented together with the current status of the different prototypes. The recent addition of a Transition Radiation Detector (TRD) to ALICE has required a revision of the requirements and the architecture of the DAQ. This will allow a higher level of data selection. These new opportunities and implementation challenges will also be presented
- …