1,480 research outputs found
Isabelle/PIDE as Platform for Educational Tools
The Isabelle/PIDE platform addresses the question whether proof assistants of
the LCF family are suitable as technological basis for educational tools. The
traditionally strong logical foundations of systems like HOL, Coq, or Isabelle
have so far been counter-balanced by somewhat inaccessible interaction via the
TTY (or minor variations like the well-known Proof General / Emacs interface).
Thus the fundamental question of math education tools with fully-formal
background theories has often been answered negatively due to accidental
weaknesses of existing proof engines.
The idea of "PIDE" (which means "Prover IDE") is to integrate existing
provers like Isabelle into a larger environment, that facilitates access by
end-users and other tools. We use Scala to expose the proof engine in ML to the
JVM world, where many user-interfaces, editor frameworks, and educational tools
already exist. This shall ultimately lead to combined mathematical assistants,
where the logical engine is in the background, without obstructing the view on
applications of formal methods, formalized mathematics, and math education in
particular.Comment: In Proceedings THedu'11, arXiv:1202.453
The Interplay between Financial Conditions and Monetary Policy Shocks
We study the interplay between monetary policy and financial conditions shocks. Such shocks have a significant and similar impact on the real economy, though with different degrees of persistence. The systematic fed funds rate response to a financial shock contributes to bringing the economy back towards trend, but a zero lower bound on policy rates can prevent this from happening, with a significant cost in terms of output and investment. In a retrospective analysis of the U.S. economy over the past 20 years, we decompose the realization of economic variables into the contributions of financial, monetary policy, and other shocks
WISE/NEOWISE observations of Active Bodies in the Main Belt
We report results based on mid-infrared photometry of 5 active main belt
objects (AMBOs) detected by the Wide-field Infrared Survey Explorer (WISE)
spacecraft. Four of these bodies, P/2010 R2 (La Sagra), 133P/Elst-Pizarro,
(596) Scheila, and 176P/LINEAR, showed no signs of activity at the time of the
observations, allowing the WISE detections to place firm constraints on their
diameters and albedos. Geometric albedos were in the range of a few percent,
and on the order of other measured comet nuclei. P/2010 A2 was observed on
April 2-3, 2010, three months after its peak activity. Photometry of the coma
at 12 and 22 {\mu}m combined with ground-based visible-wavelength measurements
provides constraints on the dust particle mass distribution (PMD), dlogn/dlogm,
yielding power-law slope values of {\alpha} = -0.5 +/- 0.1. This PMD is
considerably more shallow than that found for other comets, in particular
inbound particle fluence during the Stardust encounter of comet 81P/Wild 2. It
is similar to the PMD seen for 9P/Tempel 1 in the immediate aftermath of the
Deep Impact experiment. Upper limits for CO2 & CO production are also provided
for each AMBO and compared with revised production numbers for WISE
observations of 103P/Hartley 2.Comment: 32 Pages, including 5 Figure
Site testing for submillimetre astronomy at Dome C, Antarctica
Over the past few years a major effort has been put into the exploration of
potential sites for the deployment of submillimetre astronomical facilities.
Amongst the most important sites are Dome C and Dome A on the Antarctic
Plateau, and the Chajnantor area in Chile. In this context, we report on
measurements of the sky opacity at 200 um over a period of three years at the
French-Italian station, Concordia, at Dome C, Antarctica. We also present some
solutions to the challenges of operating in the harsh polar environ- ment. Dome
C offers exceptional conditions in terms of absolute atmospheric transmission
and stability for submillimetre astron- omy. Over the austral winter the PWV
exhibits long periods during which it is stable and at a very low level (0.1 to
0.3 mm). Higher values (0.2 to 0.8 mm) of PWV are observed during the short
summer period. Based on observations over three years, a transmission of around
50% at 350 um is achieved for 75% of the time. The 200-um window opens with a
typical transmission of 10% to 15% for 25% of the time. Dome C is one of the
best accessible sites on Earth for submillimetre astronomy. Observations at 350
or 450 {\mu}m are possible all year round, and the 200-um window opens long
enough and with a sufficient transparency to be useful. Although the polar
environment severely constrains hardware design, a permanent observatory with
appropriate technical capabilities is feasible. Because of the very good
astronomical conditions, high angular resolution and time series (multi-year)
observations at Dome C with a medium size single dish telescope would enable
unique studies to be conducted, some of which are not otherwise feasible even
from space
Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail
Background:
During routine follow-up of patients treated with a three-piece stainless-steel modular femoral nail, osteolysis and periosteal reaction around the modular junctions of some of the nails were noted on radiographs. The purpose of this study was to evaluate the prevalence, etiology, and clinical relevance of these radiographic findings.
Methods:
Forty-four femoral fractures or nonunions in forty-two patients were treated with a modular stainless-steel femoral intramedullary nail. Seventeen nails were excluded, leaving twenty-seven intramedullary nails in twenty-seven patients for this study. All patients had had a femoral diaphyseal fracture; nineteen had had an acute fracture and eight, a nonunion. These twenty-seven patients returned for radiographs, a physical examination, assessment of functional outcomes, assessment of thigh pain with a visual analog scale, determination of serum chromium levels, and nail removal if desired. A control group of sixteen patients treated with a one-piece stainless-steel femoral intramedullary nail was evaluated with use of the same outcome measures and was compared with the group treated with the modular femoral nail with regard to prevalence of thigh pain and serum chromium levels. Twelve modular femoral nails were removed according to the study protocol. The modular nail junctions were analyzed for corrosion products, and histopathologic analysis of tissue specimens from the femoral canal was performed.
Results:
The twenty-seven patients were seen at a mean of twenty-one months after fracture fixation; twenty-six of the twenty-seven fractures healed. Twenty-three femora had at least one of three types of abnormalitiesĂŠosteolysis, periosteal reaction, or cortical thickeningĂŠlocalized to one or both modular junctions. Eighteen patients had severe reactions, defined as osteolysis of 2 mm, cortical thickening of 5 mm, and/or a periosteal reaction (group 1). Nine patients had mild or no reactions (group 2). Serum chromium levels in group 1 (mean, 1.27 ng/mL; range, 0.34 to 3.12 ng/mL) were twice as high as those in group 2 (mean, 0.53 ng/mL; range, 0.12 to 1.26 ng/mL). However, this difference did not reach significance with the numbers available. The differences in serum chromium levels between group 1 and the control group with a one-piece nail (mean, 0.26 ng/mL; range, 0.015 to 1.25 ng/mL) (p \u3c 0.01) and a control group without an implant (mean, 0.05 ng/mL; range, 0.015 to 0.25 ng/mL) (p \u3c 0.01) were significant. The level of thigh pain recorded on the visual analog scale was also significantly different between group 1 and the control group with a one-piece implant (p = 0.03). Retrieved modular nails had signs of fretting corrosion as well as stainless-steel corrosion products adherent to the junction where the osteolysis occurred. Histologic and spectrographic analysis revealed two types of corrosion products that were consistent with stainless-steel within the peri-implant tissue and were associated with a foreign-body granulomatous response.
Conclusions:
The presence of corrosion products at the taper junctions suggests that particulate debris was a major factor in the etiology of the radiographic findings of osteolysis, periosteal reaction, and cortical thickening. Serum chromium levels were substantially elevated in the patients with a modular femoral nail, and such levels may serve as a marker of fretting corrosion of these devices
Researching the use of force: The background to the international project
This article provides the background to an international project on use of force by the police that was carried out in eight countries. Force is often considered to be the defining characteristic of policing and much research has been conducted on the determinants, prevalence and control of the use of force, particularly in the United States. However, little work has looked at police officersâ own views on the use of force, in particular the way in which they justify it. Using a hypothetical encounter developed for this project, researchers in each country conducted focus groups with police officers in which they were encouraged to talk about the use of force. The results show interesting similarities and differences across countries and demonstrate the value of using this kind of research focus and methodology
Comparative effectiveness of intensity modulated radiation therapy to 3-dimensional conformal radiation in locally advanced lung cancer: pathological and clinical outcomes.
OBJECTIVE: Intensity-modulated radiotherapy (IMRT) has better normal-tissue sparing compared with 3-dimensional conformal radiation (3DCRT). We sought to assess the impact of radiation technique on pathological and clinical outcomes in locally advanced non-small cell lung cancer (LANSCLC) treated with a trimodality strategy.
METHODS: Retrospective review of LANSCLC patients treated from August 2012 to August 2018 at Sheba Medical Center, Israel. The trimodality strategy consisted of concomitant chemoradiation to 60 Gray (Gy) followed by completion surgery. The planning target volume (PTV) was defined by co-registered PET/CT. Here we compare the pathological regression, surgical margin status, local control rates (LC), disease free (DFS) and overall survival (OS) between 3DCRT and IMRT.
RESULTS: Our cohort consisted of 74 patients with mean age 62.9 years, male in 51/74 (69%), adenocarcinoma in 46/74 (62.1%), stage 3 in 59/74 (79.7%) and chemotherapy in 72/74 (97.3%). Radiation mean dose: 59.2 Gy (SD ± 3.8). Radiation technique : 3DCRT in 51/74 (68.9%), IMRT in 23/74 (31%). Other variables were similar between groups.Major pathological response (including pathological complete response or less than 10% residual tumor cells) was similar: 32/51 (62.7%) in 3DCRT and 15/23 (65.2%) in IMRT, p=0.83. Pathological complete response (pCR) rates were similar: 17/51 (33.3%) in 3DCRT and 8/23 (34.8%) in IMRT, p=0.9. Surgical margins were negative in 46/51 (90.1%) in 3DCRT vs. 17/19 (89.4%) in IMRT (p=1.0).The 2-year LC rates were 81.6% (95% CI 69-89.4%); DFS 58.3% (95% CI 45.5-69%) and 3-year OS 70% (95% CI57-80%). Comparing radiation techniques, there were no significant differences in LC (p=0.94), DFS (p=0.33) and OS (p=0.72).
CONCLUSION: When used to treat LANSCLC in the neoadjuvant setting, both IMRT and 3DCRT produce comparable pathological and clinical outcomes.
ADVANCES IN KNOWLEDGE: This study validates the real-world effectiveness of IMRT compared to 3DCRT
Chondroprotection by urocortin involves blockade of the mechanosensitive ion channel Piezo1
Osteoarthritis (OA) is characterised by progressive destruction of articular cartilage and chondrocyte cell death. Here, we show the expression of the endogenous peptide urocortin1 (Ucn1) and two receptor subtypes, CRF-R1 and CRF-R2, in primary human articular chondrocytes (AC) and demonstrate its role as an autocrine/paracrine pro-survival factor. This effect could only be removed using the CRF-R1 selective antagonist CP-154526, suggesting Ucn1 acts through CRF-R1 when promoting chondrocyte survival. This cell death was characterised by an increase in p53 expression, and cleavage of caspase 9 and 3. Antagonism of CRF-R1 with CP-154526 caused an accumulation of intracellular calcium (Ca2+) over time and cell death. These effects could be prevented with the non-selective cation channel blocker Gadolinium (Gd3+). Therefore, opening of a non-selective cation channel causes cell death and Ucn1 maintains this channel in a closed conformation. This channel was identified to be the mechanosensitive channel Piezo1. We go on to determine that this channel inhibition by Ucn1 is mediated initially by an increase in cyclic adenosine monophosphate (cAMP) and a subsequent inactivation of phospholipase A2 (PLA2), whose metabolites are known to modulate ion channels. Knowledge of these novel pathways may present opportunities for interventions that could abrogate the progression of OA
Measurement of the cosmic ray spectrum above eV using inclined events detected with the Pierre Auger Observatory
A measurement of the cosmic-ray spectrum for energies exceeding
eV is presented, which is based on the analysis of showers
with zenith angles greater than detected with the Pierre Auger
Observatory between 1 January 2004 and 31 December 2013. The measured spectrum
confirms a flux suppression at the highest energies. Above
eV, the "ankle", the flux can be described by a power law with
index followed by
a smooth suppression region. For the energy () at which the
spectral flux has fallen to one-half of its extrapolated value in the absence
of suppression, we find
eV.Comment: Replaced with published version. Added journal reference and DO
- âŠ